GOEBEL CONSTRUCTION, INC | B= | C | 03/27/2013 | All other required Final inspections are complete. (This is a computer generated result) | JIMP | JIMP | | B= | C | 4495118 |
GOEBEL CONSTRUCTION, INC | B= | P | 02/22/2013 | Additional Inspections Required: External Agency Inspection F= by FIREDEPT is not Completed yet (Contact: rdassero@springsgov.com or 385-5982, x2), External Agency Inspection N= by ENGINEERING is not Completed yet (Contact: enijkamp@springsgov.com or 385-5977), External Agency Inspection PWO by WASTEWATER is not Completed yet (Contact: 668-3524), External Agency Inspection PBS by WASTEWATER is not Completed yet (Contact: 668-3524). | JIMP | JIMP | | B= | P | 4475562 |
GOEBEL CONSTRUCTION, INC | BLA | C | 12/31/2012 | | BLAKE | BLAKE | | BLA | C | 4447373 |
GOEBEL CONSTRUCTION, INC | BIN | R | 12/20/2012 | missing basement foundation wall insulation | DANF | DANF | | BIN | R | 4444005 |
GOEBEL CONSTRUCTION, INC | BFR | C | 12/20/2012 | | DANF | DANF | | BFR | C | 4444002 |
GOEBEL CONSTRUCTION, INC | BFR | R | 12/17/2012 | need to nail of hanger at T19 girder / ok to insulate | JOND | JOND | | BFR | R | 4441574 |
GOEBEL CONSTRUCTION, INC | BSP | P | 11/29/2012 | front porch OK | JIMP | JIMP | | BSP | P | 4430607 |
GOEBEL CONSTRUCTION, INC | BSP | R | 11/27/2012 | ledger is also to be nailed 3 nails at 16" o.c.; block for roof load is to be mechanically fastened | JIMP | JIMP | | BSP | R | 4428256 |
GOEBEL CONSTRUCTION, INC | BSP | R | 11/26/2012 | no plans on site at 10:50 | JIMP | JIMP | | BSP | R | 4427570 |
GOEBEL CONSTRUCTION, INC | BFI | C | 10/16/2012 | | JIMP | JIMP | | BFI | C | 4402849 |
GOEBEL CONSTRUCTION, INC | BFD | P | 10/15/2012 | still need typed foundation open hole; this is a walk out; need to call for a foundation insulation inspection. | JIMP | JIMP | | BFD | P | 4401311 |
GOEBEL CONSTRUCTION, INC | BFN | C | 10/08/2012 | need typed open hole at drain; isolate pads and float walls; eufer ground installed; 5% grade at final | JIMP | JIMP | | BFN | C | 4397460 |
GOEBEL CONSTRUCTION, INC | BFT | C | 10/04/2012 | | JIMP | JIMP | | BFT | C | 4395237 |
SANCHEZ ELECTRIC, INC. | E= | C | 02/20/2013 | 2- A/C'S INSTALLED----30 AMP--- | TIMA | TIMA | | E= | C | 4475044 |
SANCHEZ ELECTRIC, INC. | E= | R | 02/13/2013 | CAN'T RUN TC CABLE OPEN THROUGH STRUCTURE FOR A/C SPLIT UNITS,LABEL A/C UNITS,NEED WORKING CLEARANCE ON A/C DISCONNECT,NEED ALL OUTLETS 6' OF WET BAR SINK GFCI,NEED OUTLET 6' FROM WET BAR COUNTER TOP AT DOOR,NEED OUTLET IN MASTER BATH HALL GFCI,NEED GUARDED LIGHT IN BOILER ROOM UNDER STAIRS,NEED ALL OUTLETS IN GARAGE GFCI,GFCI OUTLET IN BOILER ROOM,NEED TUB ACCESS | TIMA | TIMA | | E= | R | 4471237 |
SANCHEZ ELECTRIC, INC. | ER | C | 12/13/2012 | | MIKEC | MIKEC | | ER | C | 4439495 |
SANCHEZ ELECTRIC, INC. | ES | C | 12/13/2012 | Residential Underground: new 200 amp service | MIKEC | MIKEC | | ES | C | 4439493 |
MICK HEATING & SHEET METAL CO. | H= | C | 02/20/2013 | Non-combustible mantel installed. | MICHAELS | MICHAELS | | H= | C | 4475080 |
T & N DESIGN LLC | HRR+ | C | 02/14/2013 | Boiler and vent ok. | MICHAELS | MICHAELS | | HRR+ | C | 4472188 |
MICK HEATING & SHEET METAL CO. | H= | P | 02/13/2013 | Fireplace mantel lacks clearance, Rest ok. Note: 3-mini split condensate to washer box on upper, 1-mini split on main to basement washer box, 1- mini split to shower on main. | MICHAELS | MICHAELS | | H= | P | 4471186 |
MICK HEATING & SHEET METAL CO. | HRR+ | C | 12/24/2012 | 5-future mini split linesets ok. AT FINAL: seal outside of structure. | MICHAELS | MICHAELS | | HRR+ | C | 4445341 |
MICK HEATING & SHEET METAL CO. | HC | C | 12/14/2012 | RELEASE METER | MICHAELS | MICHAELS | | HC | C | 4440597 |
MICK HEATING & SHEET METAL CO. | HRR | C | 12/14/2012 | Corrections made. | MICHAELS | MICHAELS | | HRR | C | 4440594 |
MICK HEATING & SHEET METAL CO. | HRR | P | 12/12/2012 | Exhaust over cooktop needs duct installed, laundry needs make-up air. | MICHAELS | MICHAELS | | HRR | P | 4438791 |
T & N DESIGN LLC | HWP | C | 12/07/2012 | 55# test ok on staple-up. | MICHAELS | MICHAELS | | HWP | C | 4436230 |
DAVIS GAS SHOP INC | HI | C | 12/07/2012 | 10# test ok. 2lb. to boiler, fp, c-top. BY FINAL: need CSU letter and reg install. | MICHAELS | MICHAELS | | HI | C | 4436227 |
T & N DESIGN LLC | HWP | P | 10/19/2012 | 65# test ok. 2-basement zones only. | MICHAELS | MICHAELS | | HWP | P | 4405385 |
MD SERVICE PLUMBING, INC. | P= | C | 02/20/2013 | | LEE | LEE | | P= | C | 4475118 |
MD SERVICE PLUMBING, INC. | P= | P | 02/19/2013 | PUMP ACCESS NEEDS TO BE RECOGNIZABLE (SHOW FINISHED PRODUCT) -- IRRIGATION PVB APPROX. 2' TOO LOW (MAYBE INSTALL R.P ?) | LEE | LEE | | P= | P | 4474140 |
MD SERVICE PLUMBING, INC. | P= | P | 02/13/2013 | POST ADDRESS -- LACKS IRRIGATION BACKFLOW -- LACKS MASTER TUB PUMP ACCESS -- UPPER HALL SHOWER HEAD ARM EXTREMELY LOOSE IN WALL -- COMPLETE CAULKING -- LABEL DRAIN DOWN VALVES FOR GARAGE SINK | LEE | LEE | | P= | P | 4471611 |
MD SERVICE PLUMBING, INC. | PTO | C | 12/12/2012 | | LEE | LEE | | PTO | C | 4438932 |
MD SERVICE PLUMBING, INC. | PTO | R | 12/10/2012 | WATER TEST FROZE UP SOLID (REALLY ?) WAIVED TRIP-FEE | LEE | LEE | | PTO | R | 4437492 |
MD SERVICE PLUMBING, INC. | PTO | P | 12/07/2012 | LOST TEST MASTER DWV --- NOTES FOR RBD --- BAR SINK REQUIRES AAV, FINISHED BASEMENT | LEE | LEE | | PTO | P | 4436660 |
MD SERVICE PLUMBING, INC. | PB | C | 10/16/2012 | | LEE | LEE | | PB | C | 4402874 |