HOFFMAN HOMES INC | B= | C | 09/05/2013 | | JOND | JOND | | B= | C | 4598965 |
HOFFMAN HOMES INC | B= | P | 07/30/2013 | Temp CO: all partialled ( Expires: 8/29/2013 12:00:00 AM) | JANE | JANE | | B= | P | 4573945 |
HOFFMAN HOMES INC | B= | P | 07/18/2013 | Additional Inspections Required: External Agency Inspection F= by FIREDEPT is not Completed yet (Contact: 385-5982, x2). ? on CO detectors outside bedroom areas / downspouts need on / finish final grade / need to connect post base brackets at deck / finished basement -- Schedule a new Building Final when above items are complete. | JOND | JOND | | B= | P | 4566338 |
HOFFMAN HOMES INC | BFR | C | 02/19/2013 | | JIMP | JIMP | | BFR | C | 4474359 |
HOFFMAN HOMES INC | BIN | C | 02/19/2013 | | JIMP | JIMP | | BIN | C | 4474357 |
HOFFMAN HOMES INC | BFR | R | 01/17/2013 | OK to insulate; block joist with bearing wall above (garage house wall), firestop; finish south chase at roof to check for B vent clearances. | JIMP | JIMP | | BFR | R | 4456077 |
HOFFMAN HOMES INC | BSP | T | 01/16/2013 | PAID (REC#1105851) PLAN SPLICE FEE: $50 by: MICHAEL for Construction: Revise deck plans. Partially enclose deck. | MICHAELA | MICHAELA | | BSP | T | 4454956 |
HOFFMAN HOMES INC | BFR | R | 01/11/2013 | see framers (too many items, not ready, many plans bust; structural and floor plan | JIMP | JIMP | | BFR | R | 4453112 |
HOFFMAN HOMES INC | BSP | P | 11/13/2012 | piers OK | JIMP | JIMP | | BSP | P | 4420583 |
HOFFMAN HOMES INC | BFI | C | 10/18/2012 | | JIMP | JIMP | | BFI | C | 4404294 |
HOFFMAN HOMES INC | BFN | C | 10/15/2012 | need typed open hole letter; isolate pads and float walls; 5% grade at final; eufer rod installed | JIMP | JIMP | | BFN | C | 4401834 |
HOFFMAN HOMES INC | BFT | C | 10/09/2012 | | JIMP | JIMP | | BFT | C | 4398323 |
LONGHORN ELECTRIC, INC. | E= | C | 07/02/2013 | 40 AMP A.C | MIKEC | MIKEC | | E= | C | 4556126 |
LONGHORN ELECTRIC, INC. | ER+ | C | 02/14/2013 | SUNROOM OK | TIMA | TIMA | | ER+ | C | 4472020 |
LONGHORN ELECTRIC, INC. | ES | C | 01/10/2013 | Residential Underground: 200 amp service new res | BRET | BRET | | ES | C | 4452549 |
LONGHORN ELECTRIC, INC. | ER | C | 01/10/2013 | sun room on separate permit not wired at this time. | BRET | BRET | | ER | C | 4452538 |
FALCON HEATING AND COOLING, INC. | H= | C | 07/17/2013 | Corrections made. Notes: finished basement - louvered door to mech | JERRYF | JERRYF | | H= | C | 4565613 |
FALCON HEATING AND COOLING, INC. | H= | R | 07/02/2013 | Seal coil to furnace as noted at rough, laundry lacks MUA, seal lineset on outside, no mantel installed yet. Note: full a/c. | MICHAELS | MICHAELS | | H= | R | 4555846 |
FALCON HEATING AND COOLING, INC. | HC | C | 01/02/2013 | RELEASE METER | MICHAELS | MICHAELS | | HC | C | 4447712 |
FALCON HEATING AND COOLING, INC. | HRR | C | 01/02/2013 | Correction made. | MICHAELS | MICHAELS | | HRR | C | 4447695 |
FALCON HEATING AND COOLING, INC. | HRR | T | 12/31/2012 | PAID (REC#1103097): NOT READY---DRYER VENT NOW HAS SCREWS IN EXTENSION AT FLOOR PENETRATION AND IS NOT SEALED, ALSO IS NOT SEALED AT WALL CAP CONNECTION, OTHER CORRECTIONS MADE. REINSPECTION FEE IS FOR THIRD TRIP NOW REQUIRED. COULD NOT FIND PERMIT CARD | ROBERTV | ROBERTV | | HRR | T | 4447222 |
FALCON HEATING AND COOLING, INC. | HRR | P | 12/28/2012 | Extend dryer vent into box, secure exhaust to bath fan in bsmt, support bath exhaust to be above ceiling in upper bath, Rest ok. BY FINAL: seal coil to furnace. Note: direct vent furnace and w/h, FB, a/c rough(coil and lineset) NO osa. | MICHAELS | MICHAELS | | HRR | P | 4446689 |
L & L GAS SHOP, LLC. | HI | C | 12/27/2012 | 10# test ok. 1 1/4" main to furn, on-demand w/h, c-top, fp, bbq. | MICHAELS | MICHAELS | | HI | C | 4445972 |
B & L PLUMBING, INC. | P= | C | 06/24/2013 | | JOEL | JOEL | | P= | C | 4549008 |
B & L PLUMBING, INC. | PTO | C | 12/20/2012 | PENDING MIN. W/H REQUIREMENTS (NO PLANS TO VERIFY) | LEE | LEE | | PTO | C | 4444095 |
B & L PLUMBING, INC. | PTO | P | 12/18/2012 | BUTLER SINK ON WET VENTED SECTION AT POWDER BATH, ADD BOCA ON 3" TOP PLATE IN BSMT, | LEE | LEE | | PTO | P | 4442685 |
B & L PLUMBING, INC. | PB | C | 10/22/2012 | | MARTY | MARTY | | PB | C | 4406302 |