VOLLBRACHT CONSTRUCTION | B= | C | 07/01/2013 | All other required Final inspections are complete. (This is a computer generated result) | JOND | JOND | | B= | C | 4554927 |
VOLLBRACHT CONSTRUCTION | B= | P | 07/01/2013 | Additional Inspections Required: External Agency Inspection F= by FIREDEPT is not Completed yet (Contact: 385-5982, x2). | JOND | JOND | | B= | P | 4554702 |
VOLLBRACHT CONSTRUCTION | B= | R | 05/07/2013 | Additional Inspections Required: External Agency Inspection F= by FIREDEPT is not Completed yet (Contact: 385-5982, x2). seal penetrations in deck ledger / need deck finished stairs and guardrail not installed / need handrail and guardrail at front stairs / finished basement | JOND | JOND | | B= | R | 4519027 |
VOLLBRACHT CONSTRUCTION | BFR | C | 01/30/2013 | | JIMP | JIMP | | BFR | C | 4463891 |
VOLLBRACHT CONSTRUCTION | BIN | C | 01/30/2013 | | JIMP | JIMP | | BIN | C | 4463890 |
VOLLBRACHT CONSTRUCTION | BLA | C | 01/29/2013 | | JIMP | JIMP | | BLA | C | 4463329 |
VOLLBRACHT CONSTRUCTION | BFR | R | 01/25/2013 | lateral missing at E2 / need E6 truss design / need attic vents / fireblock garage brackets / need engineer letter on foundation and pads / ok to insulate | JOND | JOND | | BFR | R | 4461232 |
VOLLBRACHT CONSTRUCTION | BTR | C | 01/22/2013 | metal roofing | JOND | JOND | | BTR | C | 4458008 |
VOLLBRACHT CONSTRUCTION | BTR | R | 01/11/2013 | Due to high winds inspection cancelled. Reschedule for 1-14-2013 | JEREMYA | JEREMYA | | BTR | R | 4453174 |
VOLLBRACHT CONSTRUCTION | BSP | P | 01/07/2013 | front and rear porches OK | JIMP | JIMP | | BSP | P | 4449955 |
VOLLBRACHT CONSTRUCTION | BSP | T | 11/21/2012 | PAID (REC#1097042) PLAN SPLICE FEE: $50 by: SHELLEY for Construction: added basement finish, foundation repair, covered decks, trusses | SHELLEY | SHELLEY | | BSP | T | 4427028 |
SOUTHERN COLORADO ELECTRIC INC. | E= | C | 05/06/2013 | | MIKEC | MIKEC | | E= | C | 4518549 |
SOUTHERN COLORADO ELECTRIC INC. | E= | C | 05/06/2013 | 2-30 AMP A.C'S | MIKEC | MIKEC | | E= | C | 4518276 |
SOUTHERN COLORADO ELECTRIC INC. | ES | C | 01/24/2013 | Residential Underground: new 150 amp service | MIKEC | MIKEC | | ES | C | 4460431 |
SOUTHERN COLORADO ELECTRIC INC. | ER | C | 01/24/2013 | raise garage outlet to 18" to bottom | MIKEC | MIKEC | | ER | C | 4460420 |
O.M.A.G.M., INC. | H= | C | 04/23/2013 | Gas final complete. | MICHAELS | MICHAELS | | H= | C | 4510812 |
KENT SHEET METAL, INC | H= | C | 04/23/2013 | Final complete. Note: full a/c. | MICHAELS | MICHAELS | | H= | C | 4510811 |
WESTERN FIREPLACE SUPPLY, INC. | H= | C | 04/19/2013 | Fireplace final complete. | MICHAELS | MICHAELS | | H= | C | 4508857 |
KENT SHEET METAL, INC | H= | P | 03/05/2013 | Duct leakage report received and sent to scanning. | MICHAELS | MICHAELS | | H= | P | 4481426 |
KENT SHEET METAL, INC | HC | C | 01/18/2013 | RELEASE METER | MICHAELS | MICHAELS | | HC | C | 4456826 |
KENT SHEET METAL, INC | HRR | C | 01/18/2013 | Rough ok. Note: FB, 6"osa, a/c rough(coil and lineset) on both systems. BY FINAL: need duct leakage report on attic system. | MICHAELS | MICHAELS | | HRR | C | 4456813 |
O.M.A.G.M., INC. | HI | C | 01/11/2013 | 10# test ok. 1 1/2" main to 2-furn, 2-w/h, c-top, 3-fp, dryer, bbq. Note: need to plug dryer line before meter can be released. | MICHAELS | MICHAELS | | HI | C | 4453222 |
WESTERN FIREPLACE SUPPLY, INC. | HV | C | 01/11/2013 | Fireplace vents ok. | MICHAELS | MICHAELS | | HV | C | 4453218 |
J D PLUMBING AND HEATING LLC | P= | C | 04/17/2013 | | LEE | LEE | | P= | C | 4507843 |
J D PLUMBING AND HEATING LLC | P= | P | 04/12/2013 | UPPER TUB PUMP ACCESS TOO SMALL -- PEX LACKS 6" TO SINGLE WALL VENT -- WATER TOO HOT LOWER SHOWER | LEE | LEE | | P= | P | 4505302 |
J D PLUMBING AND HEATING LLC | PTO | C | 01/24/2013 | | LEE | LEE | | PTO | C | 4460607 |
J D PLUMBING AND HEATING LLC | PTO | P | 12/27/2012 | NEED TO COMPLETE FRAMING IN GARAGE TO VERIFY FREEZE PROTECTION UNDER TRAPS AND PEX, COMPLETE NAIL PROTECTION 1-1/2" DWV IN BEDROOM AND SHOWER, NO CARD --- NOTES FOR FINAL --- AAV REQUIRED AT SINK UNDER STAIRS | LEE | LEE | | PTO | P | 4446295 |