CLANCY BUILDING & DESIGN, LLC | B= | C | 08/16/2013 | All other required Final inspections are complete. (This is a computer generated result) | JOND | JOND | | B= | C | 4586529 |
CLANCY BUILDING & DESIGN, LLC | B= | P | 08/14/2013 | Additional Inspections Required: External Agency Inspection F= by FIREDEPT is not Completed yet (Contact: 385-5982, x2), External Agency Inspection N= by ENGINEERING is not Completed yet (Contact: enijkamp@springsgov.com or 385-5977). | JOND | JOND | | B= | P | 4584969 |
CLANCY BUILDING & DESIGN, LLC | B= | P | 08/13/2013 | Additional Inspections Required: External Agency Inspection F= by FIREDEPT is not Completed yet (Contact: 385-5982, x2), External Agency Inspection N= by ENGINEERING is not Completed yet (Contact: enijkamp@springsgov.com or 385-5977). need handrail at garage to house steps / finished basement -- Schedule a new Building Final when above items are complete. | JOND | JOND | | B= | P | 4583992 |
CLANCY BUILDING & DESIGN, LLC | BFR | C | 05/22/2013 | | JIMP | JIMP | | BFR | C | 4528892 |
CLANCY BUILDING & DESIGN, LLC | BIN | C | 05/22/2013 | | JIMP | JIMP | | BIN | C | 4528891 |
CLANCY BUILDING & DESIGN, LLC | BTR | C | 05/20/2013 | | JOND | JOND | | BTR | C | 4526911 |
CLANCY BUILDING & DESIGN, LLC | BFR | P | 05/17/2013 | item #5 (plans show mts 12 straps at A trusses) still not done, provide eng for double h2.5's that you used/ rec'd eng and truss details for other items/ ok to insulate | BLAKE | BLAKE | | BFR | P | 4526442 |
CLANCY BUILDING & DESIGN, LLC | BFR | R | 05/16/2013 | brace off ends of laterals / need A1 trusses showing furnace on bottom cord / need straps at hinge pt at bearing balloon walls / firestop above fireplace / plans show mts12 straps at A trusses / clip A3 trusses / 4-2x6 and hts20 strap at ml beam in family rm / insulation touching b-vent at fireplace by family rm / clean out b-vent chases / plans show ml beam at back of house by kitchen / 4 ml beams need screwed off per plan note 1 / 6-2x4 under beam / 4-2x4 under ml beam / 2 h2.5 at girder in garage / clip front truss by garage door header / plans don't show header at garage to house door / basement framing not matching plans stopped inspection / give me a call at 327-2973 | JOND | JOND | | BFR | R | 4525064 |
CLANCY BUILDING & DESIGN, LLC | BLA | C | 05/06/2013 | | JOND | JOND | | BLA | C | 4517800 |
CLANCY BUILDING & DESIGN, LLC | BFN | C | 11/02/2012 | engineer's letter scanned in; drain habitable space; eufer ground installed; 10% final grade
| JIMP | JIMP | | BFN | C | 4415093 |
CLANCY BUILDING & DESIGN, LLC | BFT | C | 11/02/2012 | engineer's report scanned in | JIMP | JIMP | | BFT | C | 4415091 |
CLANCY BUILDING & DESIGN, LLC | BFI | C | 11/02/2012 | | JIMP | JIMP | | BFI | C | 4415024 |
CLANCY BUILDING & DESIGN, LLC | BFD | C | 11/02/2012 | | JIMP | JIMP | | BFD | C | 4415021 |
CLANCY BUILDING & DESIGN, LLC | BFN | P | 10/23/2012 | AUTHORIZED INSPECTION BY ENGINEER | NELIDA | NELIDA | NELIDA | BFN | P | 4407144 |
CLANCY BUILDING & DESIGN, LLC | BFT | P | 10/23/2012 | AUTHORIZED INSPECTION BY ENGINEER | NELIDA | NELIDA | NELIDA | BFT | P | 4407143 |
SANCHEZ ELECTRIC, INC. | E= | C | 08/12/2013 | 30 AMP A.C | MIKEC | MIKEC | | E= | C | 4583227 |
SANCHEZ ELECTRIC, INC. | ES | C | 05/08/2013 | Residential Underground: NEW 200 AMP SERVICE | MIKEC | MIKEC | | ES | C | 4519740 |
SANCHEZ ELECTRIC, INC. | ER | C | 05/08/2013 | SUB PANEL OK BUT NOT BREAKERED | MIKEC | MIKEC | | ER | C | 4519712 |
AIR CONCEPTS HEATING & COOLING | H= | C | 08/09/2013 | PRESSURE TEST RECEIVED AND SENT TO SCANNING OK. NOTES: FULL AC x 2 - 6" OSA TO FURNACE - 5 FIREPLACE MANTELS OK | JERRYF | JERRYF | | H= | C | 4582320 |
AIR CONCEPTS HEATING & COOLING | HC | C | 05/15/2013 | RELEASE METER | MICHAELS | MICHAELS | | HC | C | 4524139 |
AIR CONCEPTS HEATING & COOLING | HRR | C | 05/15/2013 | Corrections made. BY FINAL: need duct leakage report for attic, install p-trap on bsmt. coil. need access to attic unit. | MICHAELS | MICHAELS | | HRR | C | 4524138 |
AIR CONCEPTS HEATING & COOLING | HRR | P | 05/14/2013 | Seal wires in return in bsmt, b-vent lacks insulation shield, wire on b-vent on main, nail protect condensate drain from attic on upper level, Rest ok. Note: heat calcs ok, FB, 6" osa, a/c rough (coil and lineset) on both systems, direct vent furnace in bsmt, 90% in attic. | MICHAELS | MICHAELS | | HRR | P | 4523236 |
DAVIS GAS SHOP INC | HI | C | 05/08/2013 | 10# test ok. 2lb. system to furn, 2-w/h, 4-fp, attic furn, c-top. BY FINAL: need 2lb. letter and bonding. | MICHAELS | MICHAELS | | HI | C | 4519597 |
CHEYENNE PLUMBING & HEATING, INC. | P= | C | 08/08/2013 | HAS PVB FOR IRRIGATION | LEE | LEE | | P= | C | 4581480 |
CHEYENNE PLUMBING & HEATING, INC. | PTO | C | 05/02/2013 | | LEE | LEE | | PTO | C | 4516632 |
CHEYENNE PLUMBING & HEATING, INC. | PB | C | 11/13/2012 | COPPER WS | LYNNIE | LYNNIE | | PB | C | 4420398 |