PEAK SIDE PROPERTIES, LLC | B= | C | 07/31/2013 | | JANE | JANE | | B= | C | 4575205 |
PEAK SIDE PROPERTIES, LLC | B= | P | 07/12/2013 | Additional Inspections Required: External Agency Inspection F= by FIREDEPT is not Completed yet (Contact: 385-5982, x2), External Agency Inspection N= by ENGINEERING is not Completed yet (Contact: enijkamp@springsgov.com or 385-5977), Mechanical Final Inspection is not Completed yet. need other finals completed -- Schedule a new Building Final when above items are complete. | BLAKE | BLAKE | | B= | P | 4562454 |
PEAK SIDE PROPERTIES, LLC | BLA | C | 05/22/2013 | | JIMP | JIMP | | BLA | C | 4528907 |
PEAK SIDE PROPERTIES, LLC | BFR | C | 04/08/2013 | | JOND | JOND | | BFR | C | 4501753 |
PEAK SIDE PROPERTIES, LLC | BIN | C | 04/08/2013 | | JOND | JOND | | BIN | C | 4501752 |
PEAK SIDE PROPERTIES, LLC | BFR | R | 04/05/2013 | engineer letter for truss fixes calls for plywood on each face not just one side / tbe's at these trusses need to be used in pairs | JOND | JOND | | BFR | R | 4501019 |
PEAK SIDE PROPERTIES, LLC | BIN | P | 04/05/2013 | insulation ok / need frame signed off | JOND | JOND | | BIN | P | 4501018 |
PEAK SIDE PROPERTIES, LLC | BIN | R | 04/03/2013 | need res check on site / need frame signed off / give me a call in the morning 327-2973 | JOND | JOND | | BIN | R | 4499014 |
PEAK SIDE PROPERTIES, LLC | BFR | R | 04/01/2013 | lateral missing at H12 / trusses sitting on common wall are flipped and middle bearing is not sitting on wall / strap balloon wall / secure firestop above fireplace / need narrow braced wall detail done / ok to insulate | JOND | JOND | | BFR | R | 4497256 |
PEAK SIDE PROPERTIES, LLC | BSP | T | 03/21/2013 | PAID (REC#1118466) PLAN SPLICE FEE: $50 by: DALEH for Mechanical: relocated duct layout | DALEH | DALEH | | BSP | T | 4491578 |
PEAK SIDE PROPERTIES, LLC | BTR | C | 02/05/2013 | | DALE | DALE | | BTR | C | 4467135 |
PEAK SIDE PROPERTIES, LLC | BFD | C | 12/10/2012 | drain usable space below grade; isolate pads; float walls; 5% grade at final; eufer installed | JIMP | JIMP | | BFD | C | 4437261 |
PEAK SIDE PROPERTIES, LLC | BFN | C | 12/10/2012 | engineer observation scanned in | JIMP | JIMP | | BFN | C | 4437260 |
PEAK SIDE PROPERTIES, LLC | BFT | C | 12/10/2012 | engineer observation scanned in | JIMP | JIMP | | BFT | C | 4437259 |
PEAK SIDE PROPERTIES, LLC | BFN | P | 11/28/2012 | AUTHORIZED INSPECTION BY ENGINEER | KIM | KIM | KIM | BFN | P | 4429481 |
PEAK SIDE PROPERTIES, LLC | BFT | P | 11/28/2012 | AUTHORIZED INSPECTION BY ENGINEER | KIM | KIM | KIM | BFT | P | 4429480 |
TRUSTED ELECTRIC | E= | C | 07/11/2013 | 25 AMP A.C | MIKEC | MIKEC | | E= | C | 4561517 |
TRUSTED ELECTRIC | ER | C | 03/11/2013 | 1-15 #6AL----FINISHED BASEMENT--- | TIMA | TIMA | | ER | C | 4484839 |
TRUSTED ELECTRIC | ES | C | 03/07/2013 | Residential Underground: 200 AMP 3/W NEW RES. | TIMA | TIMA | | ES | C | 4482949 |
TRUSTED ELECTRIC | ER | R | 03/07/2013 | NEED OUTLET ON 3' WALL IN FOYER,SEAL AIR RETURN BASEMENT,WIRE HANGING OUT OF CEILING IN ENTRY HALL | TIMA | TIMA | | ER | R | 4482948 |
ADVANTAGE HEATING AND COOLING | H= | C | 07/16/2013 | Corrections made - all OK | JERRYF | JERRYF | | H= | C | 4563930 |
ADVANTAGE HEATING AND COOLING | H= | P | 07/15/2013 | Single increaser not anchored to vent outlet at unit heater - Need paperwork to verify condenser sizing. Rest OK - no permit visible - Full AC | JERRYF | JERRYF | | H= | P | 4562954 |
ADVANTAGE HEATING AND COOLING | H= | L | 07/12/2013 | Locked - no key in lock box - tried garage door also locked. | JERRYF | JERRYF | | H= | L | 4562120 |
ADVANTAGE HEATING AND COOLING | H= | P | 07/11/2013 | Remove foil tape from garage heater vent as noted at rough, sheetrock against vent in garage, need condensate drains on both waterheaters. | MICHAELS | MICHAELS | | H= | P | 4561107 |
ADVANTAGE HEATING AND COOLING | HC | C | 03/29/2013 | RELEASE METER | MICHAELS | MICHAELS | | HC | C | 4496277 |
ADVANTAGE HEATING AND COOLING | HRR | C | 03/29/2013 | Correction made. | MICHAELS | MICHAELS | | HRR | C | 4496276 |
BEST YET PLUMBING | HI+ | C | 03/28/2013 | 10# test ok. 1" stub out for future pit and dryer line ok. | MICHAELS | MICHAELS | | HI+ | C | 4495505 |
ADVANTAGE HEATING AND COOLING | HRR | P | 03/28/2013 | Correction made, w/h vents in place but exhaust is within 3' of operable window. BY FINAL: remove foil tape from vent on garage heater. | MICHAELS | MICHAELS | | HRR | P | 4495483 |
ADVANTAGE HEATING AND COOLING | HRR | P | 03/22/2013 | Nail protect dryer vent, w/h vents? Duct design and equipment ok. Note: FB, NO osa, a/c rough(coil only), direct vent furnace. | MICHAELS | MICHAELS | | HRR | P | 4492326 |
BEST YET PLUMBING | HI | C | 03/01/2013 | 10# test ok. 1 1/2" main to furn, 2-w/h, 2-range, dryer, fp, bbq, garage heater. | MICHAELS | MICHAELS | | HI | C | 4479966 |
ADVANTAGE HEATING AND COOLING | HRR | R | 02/14/2013 | Need approved plans on site, dryer vent lacks nail protection, Re-inspect all. | MICHAELS | MICHAELS | | HRR | R | 4472013 |
BEST YET PLUMBING | P= | C | 07/01/2013 | | LEE | LEE | | P= | C | 4555169 |
BEST YET PLUMBING | P= | R | 06/24/2013 | WAIVE TRIP FEE, NOT READY | JOEL | JOEL | | P= | R | 4548879 |
BEST YET PLUMBING | PTO+ | C | 03/29/2013 | RE-ROUTED W-BOX | LEE | LEE | | PTO+ | C | 4496832 |
BEST YET PLUMBING | PTO+ | P | 03/28/2013 | NO AIR ON GAUGE | LEE | LEE | | PTO+ | P | 4496080 |
BEST YET PLUMBING | PTO | C | 02/20/2013 | | LEE | LEE | | PTO | C | 4475218 |
BEST YET PLUMBING | PTO | P | 02/19/2013 | NO CARD -- W-BOX STANDPIPE TOO LONG -- NAIL PROTECTION INCOMPLETE AT URINAL AND BASEMENT BATH | LEE | LEE | | PTO | P | 4474219 |
BEST YET PLUMBING | PB | C | 12/14/2012 | | LEE | LEE | | PB | C | 4440898 |
BEST YET PLUMBING | PB | P | 12/13/2012 | INDIRECT WASTE RECEPTOR IS S-TRAPPED, PIPE NOT LAYING ON A FIRM BED | LEE | LEE | | PB | P | 4440095 |