CANAAN COMPANY, LLC | B= | C | 04/30/2013 | finished basement | JOND | JOND | | B= | C | 4514769 |
CANAAN COMPANY, LLC | BLA | C | 02/26/2013 | | JIMP | JIMP | | BLA | C | 4477719 |
CANAAN COMPANY, LLC | BIN | C | 02/06/2013 | | JIMP | JIMP | | BIN | C | 4467934 |
CANAAN COMPANY, LLC | BFR | C | 02/04/2013 | | JIMP | JIMP | | BFR | C | 4466427 |
CANAAN COMPANY, LLC | BIN | P | 02/01/2013 | Qualified third party energy inspection documentation must be presented at time of final building (B=) inspection | INTERNET | INTERNET | | BIN | P | 4465678 |
CANAAN COMPANY, LLC | BSP | P | 01/25/2013 | front and rear porches ok | JOND | JOND | | BSP | P | 4461275 |
CANAAN COMPANY, LLC | BSP | P | 12/21/2012 | deck piers ok | JOND | JOND | | BSP | P | 4444664 |
CANAAN COMPANY, LLC | BFN | C | 12/11/2012 | engineers observation on file | JIMP | JIMP | | BFN | C | 4438262 |
CANAAN COMPANY, LLC | BFT | C | 12/11/2012 | engineers observation on file | JIMP | JIMP | | BFT | C | 4438257 |
CANAAN COMPANY, LLC | BFD | C | 12/11/2012 | drain usable space; isolate pads; float walls; eufer ground installed; 5% grade at final | JIMP | JIMP | | BFD | C | 4438256 |
CANAAN COMPANY, LLC | BFI | C | 12/11/2012 | | JIMP | JIMP | | BFI | C | 4438252 |
CANAAN COMPANY, LLC | BFN | P | 11/28/2012 | AUTHORIZED INSPECTION BY ENGINEER | NELIDA | NELIDA | NELIDA | BFN | P | 4430029 |
CANAAN COMPANY, LLC | BFT | P | 11/28/2012 | AUTHORIZED INSPECTION BY ENGINEER | NELIDA | NELIDA | NELIDA | BFT | P | 4430028 |
POSITIVE ELECTRIC, LLC | E= | C | 04/19/2013 | 40 AMP A.C | MIKEC | MIKEC | | E= | C | 4509153 |
POSITIVE ELECTRIC, LLC | ES | C | 01/31/2013 | Residential Underground: 200 amp service new res. | BRET | BRET | | ES | C | 4464735 |
POSITIVE ELECTRIC, LLC | ER | C | 01/31/2013 | #6 cu to hot tub, 6 al to a/c and oven unit, sub panel ok no branch circuits made to breakers, no mcc | BRET | BRET | | ER | C | 4464722 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | C | 04/19/2013 | Corrections made. | MICHAELS | MICHAELS | | H= | C | 4508876 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | P | 04/11/2013 | Mech room lacks combustion air, need T&P installed on w/h, furnace intake full of stucco. Note: mantel clearance ok and full a/c. | MICHAELS | MICHAELS | | H= | P | 4504372 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HC | C | 02/04/2013 | OK TO SET METER. | NANCY | NANCY | | HC | C | 4466135 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | C | 02/04/2013 | CORRECTIONS MADE. NOTE: FINISHED BASEMENT. OUTSIDE AIR TIED TO FURNACE RETURN. A/C ROUGH, COIL AND LINESET. DIRECT VENT FURNACE. | NANCY | NANCY | | HRR | C | 4466134 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | P | 02/01/2013 | Need 6" osa installed per plan, pan return on main with open cavity behind. Rest ok. | MICHAELS | MICHAELS | | HRR | P | 4465427 |
DOUBLE J GAS, INC. | HI | C | 01/25/2013 | 10# test ok. 1 1/4" main to furn, w/h, c-top, fp, bbq. | MICHAELS | MICHAELS | | HI | C | 4461079 |
UNIQUE RADIANT HTG. & PLBG. | P= | C | 04/16/2013 | | LEE | LEE | | P= | C | 4507171 |
UNIQUE RADIANT HTG. & PLBG. | P= | P | 04/15/2013 | COULD NOT LOCATE 12 X 12 ACCESS PANEL FOR MASTER BATH C/O (SEE CARD) --- NOTES FOR RBD --- HAS PVB FOR IRRIGATION | LEE | LEE | | P= | P | 4506265 |
UNIQUE RADIANT HTG. & PLBG. | PTO | C | 02/01/2013 | | LEE | LEE | | PTO | C | 4465568 |
UNIQUE RADIANT HTG. & PLBG. | PTO | P | 01/31/2013 | NAIL PROTECTION INCOMPLETE -- USE BOCA PLATES AT GARAGE SILLCOCK -- LACKS 3.5" BEHIND WATER LINES AT W-BOX -- NO 3" C/O ACCESS AT CHASE --- NOTES FOR RBD --- BAR SINK REQUIRES AAV -- TWO TRAPS NOT ALLOWED AT KITCHEN SINK ON FINAL | LEE | LEE | | PTO | P | 4464864 |
UNIQUE RADIANT HTG. & PLBG. | PB | C | 12/17/2012 | | LEE | LEE | | PB | C | 4441736 |