C. R. SHEA HOMES, INC. | B= | C | 10/15/2013 | All other required Final inspections are complete. (This is a computer generated result) | JOND | JOND | | B= | C | 4622704 |
C. R. SHEA HOMES, INC. | B= | P | 10/15/2013 | Additional Inspections Required: External Agency Inspection N= by ENGINEERING is not Completed yet (Contact: enijkamp@springsgov.com or 385-5977). finished basement | JOND | JOND | | B= | P | 4622686 |
C. R. SHEA HOMES, INC. | BLA | C | 04/26/2013 | | JOND | JOND | | BLA | C | 4512721 |
C. R. SHEA HOMES, INC. | BFR | C | 04/24/2013 | | JOND | JOND | | BFR | C | 4511379 |
C. R. SHEA HOMES, INC. | BIN | C | 04/24/2013 | | JOND | JOND | | BIN | C | 4511378 |
C. R. SHEA HOMES, INC. | BFR | R | 04/22/2013 | missing hangers at 2x10 joists in basement at far east end / ok to insulate | JOND | JOND | | BFR | R | 4509740 |
C. R. SHEA HOMES, INC. | BFR | R | 04/19/2013 | plans and trusses are not matching up, stopped inspection | JOND | JOND | | BFR | R | 4508945 |
C. R. SHEA HOMES, INC. | BTR | C | 03/22/2013 | | JOND | JOND | | BTR | C | 4492303 |
C. R. SHEA HOMES, INC. | BFD | C | 12/17/2012 | Drain day lights at SE corner. | ROGER | ROGER | | BFD | C | 4440993 |
C. R. SHEA HOMES, INC. | BFN | C | 12/10/2012 | need full soils and typed open hole at drain; drain usable space; isolate pads; float walls; eufer ground installed | JIMP | JIMP | | BFN | C | 4437272 |
C. R. SHEA HOMES, INC. | BFT | C | 12/06/2012 | | JIMP | JIMP | | BFT | C | 4435251 |
D & J QUALITY ELECTRIC INC | E= | C | 10/08/2013 | corrections made | BRIAN | BRIAN | | E= | C | 4618704 |
D & J QUALITY ELECTRIC INC | E= | R | 10/07/2013 | GFCI to the left of the sink still will not reset | CRAIGS | CRAIGS | | E= | R | 4617777 |
D & J QUALITY ELECTRIC INC | E= | R | 10/03/2013 | GFI OUTLETS IN LAUNDRY ROOM, KITCHEN GFI WON'T RESET------------------ 30 AMP A.C | MIKEC | MIKEC | | E= | R | 4616191 |
D & J QUALITY ELECTRIC INC | ER | C | 04/18/2013 | DID NOT SEE PERMIT | MIKEC | MIKEC | | ER | C | 4508416 |
D & J QUALITY ELECTRIC INC | ES | C | 04/18/2013 | Residential Underground: NEW 200 AMP SERVICE | MIKEC | MIKEC | | ES | C | 4508415 |
BRUNO'S HEATING & COOLING | H= | C | 10/14/2013 | hi/lo grills added, all good | MARK | MARK | | H= | C | 4622218 |
BRUNO'S HEATING & COOLING | H= | P | 10/11/2013 | NEED TRANSFER TO MECH FOR WATER HEATERS - REST OK. NOTES: FULL AC - MAIN FP MANTEL OK - BASEMENT FP NO MANTEL | JERRYF | JERRYF | | H= | P | 4621239 |
ALPINE CREST PLBG. & HEATING INC. | HC | C | 04/18/2013 | RELEASE METER | LEE | LEE | | HC | C | 4508595 |
ALPINE CREST PLBG. & HEATING INC. | HI | C | 04/18/2013 | FURNACE -- W/H X-2 -- F/P X-2 -- C-TOP -- BBQ | LEE | LEE | | HI | C | 4508594 |
BRUNO'S HEATING & COOLING | HRR | C | 04/12/2013 | Corrections made. | MICHAELS | MICHAELS | | HRR | C | 4504983 |
BRUNO'S HEATING & COOLING | HRR | P | 04/11/2013 | POST ADDRESS AND CARD, seal 8x8 R/A jumper in soffit, add bath fan in bath area in bsmt bath next to mech. Note: FB, no osa, a/c rough(coil and lineset), direct vent furnace. | MICHAELS | MICHAELS | | HRR | P | 4504298 |
ALPINE CREST PLBG. & HEATING INC. | P= | C | 10/02/2013 | | LEE | LEE | | P= | C | 4615356 |
ALPINE CREST PLBG. & HEATING INC. | PTO | C | 04/18/2013 | | LEE | LEE | | PTO | C | 4508596 |
ALPINE CREST PLBG. & HEATING INC. | PB | C | 01/17/2013 | | LEE | LEE | | PB | C | 4456388 |