THE NEWPORT COMPANY | B= | C | 08/07/2013 | All other required Final inspections are complete. (This is a computer generated result) | JOND | JOND | | B= | C | 4580392 |
THE NEWPORT COMPANY | B= | P | 08/06/2013 | Additional Inspections Required: External Agency Inspection N= by ENGINEERING is not Completed yet (Contact: enijkamp@springsgov.com or 385-5977). | JOND | JOND | | B= | P | 4579321 |
THE NEWPORT COMPANY | B= | P | 08/02/2013 | Additional Inspections Required: External Agency Inspection F= by FIREDEPT is not Completed yet (Contact: 385-5982, x2), External Agency Inspection N= by ENGINEERING is not Completed yet (Contact: enijkamp@springsgov.com or 385-5977). need 5" house numbers / need handrail at front steps / need guardrail finished at deck / finished basement -- Schedule a new Building Final when above items are complete. | JOND | JOND | | B= | P | 4577730 |
THE NEWPORT COMPANY | BSP | P | 06/27/2013 | fireplace framing ok | JOND | JOND | | BSP | P | 4552535 |
THE NEWPORT COMPANY | BSP | R | 06/14/2013 | fireplace framing at back porch --- need 1" clearance to the back of fireplace / need to firestop at ceiling / need electrical inspected | JOND | JOND | | BSP | R | 4543542 |
THE NEWPORT COMPANY | BLA | C | 05/15/2013 | | JOND | JOND | | BLA | C | 4524520 |
THE NEWPORT COMPANY | BIN | C | 04/17/2013 | | JOND | JOND | | BIN | C | 4507793 |
THE NEWPORT COMPANY | BFR | C | 04/17/2013 | | JOND | JOND | | BFR | C | 4507792 |
THE NEWPORT COMPANY | BFR | R | 04/15/2013 | 3 ml header in garage / clip corner mono in garage / firestop chase in garage / ok to insulate | JOND | JOND | | BFR | R | 4506235 |
THE NEWPORT COMPANY | BTR | C | 04/03/2013 | | JOND | JOND | | BTR | C | 4499226 |
THE NEWPORT COMPANY | BSP | P | 03/18/2013 | deck piers ok | JOND | JOND | | BSP | P | 4489174 |
THE NEWPORT COMPANY | BSP | P | 02/25/2013 | rear deck ceiling OK to cover | JIMP | JIMP | | BSP | P | 4477081 |
THE NEWPORT COMPANY | BFI | C | 12/17/2012 | | JOND | JOND | | BFI | C | 4440990 |
THE NEWPORT COMPANY | BFN | C | 12/17/2012 | engineer letter on file / design and soils on file / ok per Jim P. | JOND | JOND | | BFN | C | 4440989 |
THE NEWPORT COMPANY | BFD | C | 12/17/2012 | usable drain per Jim P. | JOND | JOND | | BFD | C | 4440988 |
THE NEWPORT COMPANY | BFN | P | 12/14/2012 | AUTHORIZED INSPECTION BY ENGINEER | REBECCA | REBECCA | REBECCA | BFN | P | 4440132 |
THE NEWPORT COMPANY | BFN | T | 12/11/2012 | PAID (REC#1100688) not even close at 9:35; steel missing in garage and tall walls | JIMP | JIMP | | BFN | T | 4437988 |
THE NEWPORT COMPANY | BFT | C | 12/05/2012 | | JIMP | JIMP | | BFT | C | 4434548 |
MEYER ELECTRIC | E= | C | 07/31/2013 | 2- 30 AMP A.C'S | MIKEC | MIKEC | | E= | C | 4575458 |
MEYER ELECTRIC | ES | C | 04/04/2013 | Residential Underground: new 200 amp service | MIKEC | MIKEC | | ES | C | 4500089 |
MEYER ELECTRIC | ER | C | 04/04/2013 | | MIKEC | MIKEC | | ER | C | 4500075 |
GENE'S HEATING AND AIR LLC | H= | C | 08/01/2013 | NOTES REVISED 8/2/2013 OK NOTES: HIGH / LOW GRILLES TO MECH | JERRYF | JERRYF | | H= | C | 4576497 |
GENE'S HEATING AND AIR LLC | H= | P | 07/31/2013 | Notes revised 8/1/2012 Need to label all drains from 2nd floor in basement mech room - need transfer air from mech to common area in basement - main floor fireplace install manual on pg. 2 shows 8" deep mantel 14" above opening has 12" deep mantel at 9" above need paper from the manufacture stating that non combustible mantel is OK- all other mantels are OK - Rest OK. NOTES: FULL AC x 2 | JERRYF | JERRYF | | H= | P | 4575677 |
GENE'S HEATING AND AIR LLC | H= | P | 07/17/2013 | Duct leakage report received and sent to scanning. | MICHAELS | MICHAELS | | H= | P | 4564849 |
WESTERN FIREPLACE SUPPLY, INC. | HRR+ | P | 06/26/2013 | Need to re-call building inspector for this. | MICHAELS | MICHAELS | | HRR+ | P | 4551439 |
GENE'S HEATING AND AIR LLC | HV | P | 05/10/2013 | Vent for fp on patio needs to be inspected by building. | MICHAELS | MICHAELS | | HV | P | 4521767 |
GENE'S HEATING AND AIR LLC | HC | C | 04/12/2013 | RELEASE METER | MICHAELS | MICHAELS | | HC | C | 4505009 |
GENE'S HEATING AND AIR LLC | HRR | C | 04/12/2013 | Correction made. AT FINAL: check R/A in walls of mech. Need duct leakage report for attic system. Note: FB, no osa, a/c rough(coil and lineset) on main and upper level, no a/c on basement system, direct vent furnace x3. | MICHAELS | MICHAELS | | HRR | C | 4505008 |
GENE'S HEATING AND AIR LLC | HRR | R | 04/10/2013 | Garage heater vent corrected, still have issue with 5" b-vent for waterheaters. Panning for returns in mech room? | MICHAELS | MICHAELS | | HRR | R | 4503433 |
GENE'S HEATING AND AIR LLC | HRR | P | 04/05/2013 | B-vent and garage heater vent horizontal length far exceed vertical length, upper fp vent lacks clearance to framing. If mech room is unfinished low returns in walls need to be fully panned. | MICHAELS | MICHAELS | | HRR | P | 4500877 |
PLATINUM PLUMBING INC | HI | C | 04/01/2013 | 10# test ok. 1 1/2" main to 3-furn, 2-w/h, c-top, bbq, 5-fp, garage htr. | MICHAELS | MICHAELS | | HI | C | 4497368 |
UNIQUE RADIANT HTG. & PLBG. | P= | C | 08/01/2013 | | LEE | LEE | | P= | C | 4576807 |
UNIQUE RADIANT HTG. & PLBG. | P= | P | 07/31/2013 | MISSING AIR GAPS / DRAIN CONNECTIONS AT BOTH DISHWASHERS -- STEAM GEN. REQUIRES 6" CLEARANCE ALL AROUND -- LEAK UNDER BAR SINK -- GARAGE SINK NOT INSTALLED | LEE | LEE | | P= | P | 4575869 |
UNIQUE RADIANT HTG. & PLBG. | PTO | C | 04/09/2013 | | LEE | LEE | | PTO | C | 4502942 |
UNIQUE RADIANT HTG. & PLBG. | PB | C | 12/21/2012 | | LEE | LEE | | PB | C | 4445044 |