VANTAGE HOMES CORP. | B= | C | 05/21/2013 | All other required Final inspections are complete. (This is a computer generated result) | JOND | JOND | | B= | C | 4528196 |
VANTAGE HOMES CORP. | B= | P | 05/21/2013 | Additional Inspections Required: External Agency Inspection N= by ENGINEERING is not Completed yet (Contact: enijkamp@springsgov.com or 385-5977). finished basement | JOND | JOND | | B= | P | 4527707 |
VANTAGE HOMES CORP. | BSP | R | 04/03/2013 | deck piers ok / deck frame no approved plans or structural pages on site | JOND | JOND | | BSP | R | 4499093 |
VANTAGE HOMES CORP. | BLA | C | 03/29/2013 | | JOND | JOND | | BLA | C | 4496859 |
VANTAGE HOMES CORP. | BIN | C | 03/12/2013 | | JIMP | JIMP | | BIN | C | 4485865 |
VANTAGE HOMES CORP. | BFR | C | 03/12/2013 | | JIMP | JIMP | | BFR | C | 4485864 |
VANTAGE HOMES CORP. | BFR | P | 03/08/2013 | bearing walls above basement beams; joist need blocked | JIMP | JIMP | | BFR | P | 4483890 |
VANTAGE HOMES CORP. | BFD | C | 01/10/2013 | drain habitable space; isolate pads'; float walls; 10% grade at final; eufer OK | JIMP | JIMP | | BFD | C | 4452389 |
VANTAGE HOMES CORP. | BFN | C | 01/10/2013 | engineer's observation on file | JIMP | JIMP | | BFN | C | 4452385 |
VANTAGE HOMES CORP. | BFT | C | 01/10/2013 | engineers observation on file | JIMP | JIMP | | BFT | C | 4452384 |
VANTAGE HOMES CORP. | BFI | C | 01/10/2013 | | JIMP | JIMP | | BFI | C | 4452382 |
D & J QUALITY ELECTRIC INC | E= | C | 05/10/2013 | 20 AMP A.C | MIKEC | MIKEC | | E= | C | 4521593 |
D & J QUALITY ELECTRIC INC | E= | R | 05/09/2013 | NO POWER TO LAUNDRY CIRCUIT, LABEL A.C IN PANEL | MIKEC | MIKEC | | E= | R | 4520780 |
D & J QUALITY ELECTRIC INC | ES | C | 03/04/2013 | Residential Underground: 200 AMP 3/W NEW RES. | TIMA | TIMA | | ES | C | 4481035 |
D & J QUALITY ELECTRIC INC | ES | R | 03/01/2013 | NEED LISTED LUG FOR SUB PANEL FEEDER NEUTRAL | TIMA | TIMA | | ES | R | 4480306 |
D & J QUALITY ELECTRIC INC | ER | C | 03/01/2013 | NO MULTI WIRE #8 CU -------SUB PANEL OK----FINISHED BASEMENT--- | TIMA | TIMA | | ER | C | 4480300 |
ATLANTIC HEATING & A/C INC | H= | C | 05/13/2013 | Mantel clearances ok. | MICHAELS | MICHAELS | | H= | C | 4522370 |
ATLANTIC HEATING & A/C INC | H= | P | 05/10/2013 | B-vent cap installed, still need mantels installed. | MICHAELS | MICHAELS | | H= | P | 4521720 |
ATLANTIC HEATING & A/C INC | H= | P | 05/09/2013 | Need b-vent cap installed, install mantels to check clearance, Rest ok. Note: high/low transfer in wall and full a/c. | MICHAELS | MICHAELS | | H= | P | 4520676 |
ATLANTIC HEATING & A/C INC | HC | C | 02/28/2013 | RELEASE METER | MICHAELS | MICHAELS | | HC | C | 4479290 |
ATLANTIC HEATING & A/C INC | HRR | C | 02/28/2013 | Performance test received and sent to scanning, rough ok. Note: FB, 6" osa, a/c rough(coil and lineset), direct vent furnace. | MICHAELS | MICHAELS | | HRR | C | 4479289 |
L & L GAS SHOP, LLC. | HI | C | 02/20/2013 | 10# test ok. 1 1/4" main to furn, w/h, 2-fp, c-top, 2-bbq. | MICHAELS | MICHAELS | | HI | C | 4475058 |
TEAM PLUMBING, INC. | P= | C | 05/14/2013 | PVB INSTALLED FOR IRRIGATION | LEE | LEE | | P= | C | 4523649 |
TEAM PLUMBING, INC. | PTO | C | 02/22/2013 | STILL MISSING NAIL PLATE ON SILL-COCK IN LAUNDRY ROOM | LEE | LEE | | PTO | C | 4476320 |
TEAM PLUMBING, INC. | PTO | P | 02/20/2013 | LOW TEST ON H20 -- ADD NAIL PLATE AT SILLCOCK -- REST OK | LEE | LEE | | PTO | P | 4475169 |
TEAM PLUMBING, INC. | PB | C | 01/22/2013 | | LEE | LEE | | PB | C | 4458522 |