SCOTT BUILDING, INC | B= | C | 07/12/2013 | | BLAKE | BLAKE | | B= | C | 4562478 |
SCOTT BUILDING, INC | B= | P | 07/10/2013 | Additional Inspections Required: External Agency Inspection N= by ENGINEERING is not Completed yet (Contact: enijkamp@springsgov.com or 385-5977). 1- adjust final grade 2- address #'s 3- need handrail at garage/house stairs 4- remove all smoke detector dust covers 5- need solid core or fire rated garage/house door installed -- Schedule a new Building Final when above items are complete. | BLAKE | BLAKE | | B= | P | 4560678 |
SCOTT BUILDING, INC | BTR | C | 05/22/2013 | | JEREMYC | JEREMYC | | BTR | C | 4529024 |
SCOTT BUILDING, INC | BLA | C | 04/25/2013 | | JOND | JOND | | BLA | C | 4512039 |
SCOTT BUILDING, INC | BSP | P | 04/15/2013 | rear porch posts ok | JOND | JOND | | BSP | P | 4506013 |
SCOTT BUILDING, INC | BSP | P | 04/08/2013 | back porch piers ok | JOND | JOND | | BSP | P | 4501754 |
SCOTT BUILDING, INC | BIN | C | 03/26/2013 | | JOND | JOND | | BIN | C | 4493935 |
SCOTT BUILDING, INC | BFR | C | 03/26/2013 | | JOND | JOND | | BFR | C | 4493929 |
SCOTT BUILDING, INC | BFR | R | 03/22/2013 | pt load down GG in garage / tbe missing at GG1 in garage / lateral missing at B14, B9 / block ridge board at overframe at front of house / plans show hts16 straps at back porch / need roof vents / ok to insulate | JOND | JOND | | BFR | R | 4492406 |
SCOTT BUILDING, INC | BSP | T | 03/19/2013 | PAID (REC#1118105) PLAN SPLICE FEE: $50 by: DALEH for Mechanical: splice to change duct design from offset to straight layout | DALEH | DALEH | | BSP | T | 4489873 |
SCOTT BUILDING, INC | BFD | C | 02/04/2013 | engineers observation on file | JIMP | JIMP | | BFD | C | 4466128 |
SCOTT BUILDING, INC | BFN | C | 02/04/2013 | engineers observation on file; eufer OK; drain; isolate pads; float walls; 5% grade at final | JIMP | JIMP | | BFN | C | 4466127 |
SCOTT BUILDING, INC | BFT | C | 02/04/2013 | engineers observation on file | JIMP | JIMP | | BFT | C | 4466123 |
SCOTT BUILDING, INC | BFD | R | 01/17/2013 | provide engineering letter on drain (already backfilled), provide department with all paper work with drain letter (engineering observation of footing, foundation, soils, open hole, foundation design) | JIMP | JIMP | | BFD | R | 4456085 |
SCOTT BUILDING, INC | BFD | T | 01/11/2013 | PAID (REC#1106049) no plans; permit; engineers observations on site at 10;15. | JIMP | JIMP | | BFD | T | 4453105 |
SCOTT BUILDING, INC | BFN | P | 12/21/2012 | AUTHORIZED INSPECTION BY ENGINEER | KIM | KIM | KIM | BFN | P | 4444331 |
SCOTT BUILDING, INC | BFT | P | 12/21/2012 | AUTHORIZED INSPECTION BY ENGINEER | KIM | KIM | KIM | BFT | P | 4444330 |
D & J QUALITY ELECTRIC INC | E= | C | 07/09/2013 | 30 AMP A.C | MIKEC | MIKEC | | E= | C | 4559460 |
D & J QUALITY ELECTRIC INC | ES | C | 03/19/2013 | Residential Underground: new 200 amp service | MIKEC | MIKEC | | ES | C | 4490065 |
D & J QUALITY ELECTRIC INC | ER | C | 03/19/2013 | 10 | MIKEC | MIKEC | | ER | C | 4490064 |
REGIONAL HEATING AND AIR CONDITIONING, INC. | H= | C | 07/10/2013 | Correction made. | MICHAELS | MICHAELS | | H= | C | 4559828 |
J.J. BROOME PLUMBING AND HEATING LLC | H= | P | 07/09/2013 | Will final when heating contractor is complete. | MICHAELS | MICHAELS | | H= | P | 4559365 |
REGIONAL HEATING AND AIR CONDITIONING, INC. | H= | P | 07/09/2013 | Concentric vent termination is buried in stucco, Rest ok. Note: direct vent appliances and full a/c. | MICHAELS | MICHAELS | | H= | P | 4559363 |
L & L GAS SHOP, LLC. | HI+ | C | 06/17/2013 | 10# test ok. 3/4" poly from house stub to firepit. Note: pit cannot exceed 100k BTU. | MICHAELS | MICHAELS | | HI+ | C | 4544198 |
REGIONAL HEATING AND AIR CONDITIONING, INC. | HRR | C | 03/21/2013 | OK NOTE FINISHED BASEMENT 6" OSA | DAVIDH | DAVIDH | | HRR | C | 4491761 |
L & L GAS SHOP, LLC. | HC | C | 03/21/2013 | RELEASE METER | DAVIDH | DAVIDH | | HC | C | 4491762 |
L & L GAS SHOP, LLC. | HI | C | 03/21/2013 | 10 LB TEST OK NOTE 1 FURN,BOILER,F/P C/T DRYER,BBQ,FUTURE OSFIREPLACE | DAVIDH | DAVIDH | | HI | C | 4491743 |
J.J. BROOME PLUMBING AND HEATING LLC | HV | C | 03/19/2013 | Boiler vent ok. | MICHAELS | MICHAELS | | HV | C | 4489975 |
J.J. BROOME PLUMBING AND HEATING LLC | HWP | C | 03/14/2013 | 55# test ok. Staple up for master and guest bath only. | MICHAELS | MICHAELS | | HWP | C | 4487098 |
J.J. BROOME PLUMBING AND HEATING LLC | HWP | P | 01/22/2013 | 65# test ok. 3-basement zones ok. | MICHAELS | MICHAELS | | HWP | P | 4458168 |
J.J. BROOME PLUMBING AND HEATING LLC | P= | C | 06/24/2013 | RPBFP INTALLED | JOEL | JOEL | | P= | C | 4548913 |
J.J. BROOME PLUMBING AND HEATING LLC | PTO | C | 03/12/2013 | | MARTY | MARTY | | PTO | C | 4485530 |
J.J. BROOME PLUMBING AND HEATING LLC | PB+ | C | 01/16/2013 | ADDED SHOWER | LEE | LEE | | PB+ | C | 4455646 |
J.J. BROOME PLUMBING AND HEATING LLC | PB | C | 01/09/2013 | | LEE | LEE | | PB | C | 4451959 |
J.J. BROOME PLUMBING AND HEATING LLC | PB | P | 01/08/2013 | NO H20 SERVICE, DWV OK | LEE | LEE | | PB | P | 4451119 |