GC LUXURY HOMES, LLC | B= | C | 07/01/2013 | All other required Final inspections are complete. (This is a computer generated result) | JOND | JOND | | B= | C | 4554780 |
GC LUXURY HOMES, LLC | B= | P | 06/28/2013 | Additional Inspections Required: External Agency Inspection F= by FIREDEPT is not Completed yet (Contact: 385-5982, x2), Mechanical Final Inspection is not Completed yet. need mechanical final signed off / finished basement | JOND | JOND | | B= | P | 4553597 |
GC LUXURY HOMES, LLC | BLA | C | 04/24/2013 | | JOND | JOND | | BLA | C | 4511414 |
GC LUXURY HOMES, LLC | BFR | C | 04/10/2013 | | JOND | JOND | | BFR | C | 4503519 |
GC LUXURY HOMES, LLC | BIN | C | 04/10/2013 | | JOND | JOND | | BIN | C | 4503518 |
GC LUXURY HOMES, LLC | BFR | R | 04/05/2013 | hts20 straps at 3 ml's / hts20 at GG1 / strap corner and peak at front wall / hts20 at glue lam above front entry / lags at ledger per plan / ml hanger not nailed off in master br / need tbe's at A trusses at common wall / need narrow brace wall detail / ok to insulate | JOND | JOND | | BFR | R | 4501103 |
GC LUXURY HOMES, LLC | BSP | P | 04/04/2013 | front and rear porches ok | JOND | JOND | | BSP | P | 4500099 |
GC LUXURY HOMES, LLC | BSP | T | 04/03/2013 | PAID (REC#1121066): no plans on site at 10:58 | JOND | JOND | | BSP | T | 4498981 |
GC LUXURY HOMES, LLC | BSP | P | 03/22/2013 | insulation in wall in mechanical room ok | JOND | JOND | | BSP | P | 4492437 |
GC LUXURY HOMES, LLC | BFD | C | 01/11/2013 | | JIMP | JIMP | | BFD | C | 4453108 |
GC LUXURY HOMES, LLC | BFN | C | 01/07/2013 | drain usable space; eufer installed; need full soils and typed open hole at drain | JIMP | JIMP | | BFN | C | 4449964 |
GC LUXURY HOMES, LLC | BFT | C | 01/02/2013 | | JIMP | JIMP | | BFT | C | 4447861 |
BLUE MOUNTAIN ELECTRIC, INC. | E= | C | 06/19/2013 | 30 AMP A.C | MIKEC | MIKEC | | E= | C | 4546047 |
BLUE MOUNTAIN ELECTRIC, INC. | E= | C | 06/19/2013 | | MIKEC | MIKEC | | E= | C | 4546010 |
BLUE MOUNTAIN ELECTRIC, INC. | ER | C | 04/01/2013 | 1-20mcc #6al to range | BRET | BRET | | ER | C | 4497616 |
BLUE MOUNTAIN ELECTRIC, INC. | ES | C | 03/28/2013 | Residential Underground: 200 amp service new res. | BRET | BRET | | ES | C | 4495790 |
BLUE MOUNTAIN ELECTRIC, INC. | ER | R | 03/28/2013 | install gec to water copper entering structure. 1-20 amp mcc, #6 al to range. | BRET | BRET | | ER | R | 4495786 |
CLANTON HEATING & AIR, INC. | H= | C | 07/01/2013 | Corrections made. | MICHAELS | MICHAELS | | H= | C | 4554779 |
CLANTON HEATING & AIR, INC. | H= | P | 06/27/2013 | Laundry lacks MUA, extend suction line insulation to face of coil, Rest ok. Note: mantel clearance ok and full a/c installed. | MICHAELS | MICHAELS | | H= | P | 4552591 |
BURNS RITE GAS | H= | C | 06/26/2013 | This is new construction, gas will be finaled when heating final is called in. | MICHAELS | MICHAELS | | H= | C | 4551346 |
BURNS RITE GAS | HWP | C | 04/11/2013 | 80# test ok. Staple down on main and upper levels. | MICHAELS | MICHAELS | | HWP | C | 4504297 |
BURNS RITE GAS | HC | C | 04/04/2013 | RELEASE METER | MICHAELS | MICHAELS | | HC | C | 4499975 |
BURNS RITE GAS | HI | C | 04/04/2013 | 10# test ok. 1 1/4" main to boiler, 2-fp, c-top. | MICHAELS | MICHAELS | | HI | C | 4499974 |
CLANTON HEATING & AIR, INC. | HRR | C | 04/02/2013 | Rough ok. Note: air handler for a/c, FB, direct vent boiler. | MICHAELS | MICHAELS | | HRR | C | 4498422 |
CLANTON HEATING & AIR, INC. | HWP | P | 01/22/2013 | 80# test ok. 2-basement zones ok. | MICHAELS | MICHAELS | | HWP | P | 4458136 |
C & T PLUMBING, LLC. | P= | C | 06/24/2013 | PVB INSTALLED | JOEL | JOEL | | P= | C | 4548933 |
C & T PLUMBING, LLC. | P= | C | 06/24/2013 | PVB INSTALLED | JOEL | JOEL | | P= | C | 4548924 |
C & T PLUMBING, LLC. | PTO | C | 03/29/2013 | | LEE | LEE | | PTO | C | 4496853 |
C & T PLUMBING, LLC. | PTO | P | 03/22/2013 | SUPPORT DWV AT CHANGES OF DIRECTION THRU-OUT -- SUPPORT VENT IN ATTIC -- COMPLETE -- INSTALL PERMANENT CAP ON 3" IN WALL -- COMPLETE NAIL PROTECTION THERE AND AT ICE MAKER BOX -- BASEMENT BAR SINK ON BATHROOM WET VENT -- REROUTE SILL COCK - NEED 3.5" BEHIND FOR FREEZE PROTECTION -- PROVIDE FREEZE PROTECTION AT W-BOX P-TRAP -- INSTALL SAN-TEE AT FUTURE LAV | LEE | LEE | | PTO | P | 4492729 |
C & T PLUMBING, LLC. | PB | C | 01/18/2013 | | LEE | LEE | | PB | C | 4457282 |