TUSCANY HOMES LLC | B= | C | 06/17/2013 | All other required Final inspections are complete. (This is a computer generated result) | JOND | JOND | | B= | C | 4544661 |
TUSCANY HOMES LLC | B= | P | 06/14/2013 | Additional Inspections Required: External Agency Inspection N= by ENGINEERING is not Completed yet (Contact: enijkamp@springsgov.com or 385-5977). | JOND | JOND | | B= | P | 4543347 |
TUSCANY HOMES LLC | B= | R | 06/12/2013 | Additional Inspections Required: External Agency Inspection F= by FIREDEPT is not Completed yet (Contact: 385-5982, x2), External Agency Inspection N= by ENGINEERING is not Completed yet (Contact: enijkamp@springsgov.com or 385-5977). need to drywall under stairs in garage / master shower glass not in / need ladder for attic access / need landing out back deck stairs / finished basement | JOND | JOND | | B= | R | 4541655 |
TUSCANY HOMES LLC | BSP | P | 06/04/2013 | PLAN SPLICE: (No Fee) by: DALEH for Mechanical | DALEH | DALEH | | BSP | P | 4536630 |
TUSCANY HOMES LLC | BSP | R | 05/16/2013 | plans don't show size for deck piers | JOND | JOND | | BSP | R | 4525103 |
TUSCANY HOMES LLC | BSP | P | 04/29/2013 | front porch post ok | JOND | JOND | | BSP | P | 4513566 |
TUSCANY HOMES LLC | BSP | P | 04/05/2013 | front pier ok | JOND | JOND | | BSP | P | 4500901 |
TUSCANY HOMES LLC | BIN | C | 03/26/2013 | | JOND | JOND | | BIN | C | 4493718 |
TUSCANY HOMES LLC | BIN | T | 03/25/2013 | PAID (REC#1118954) ceiling above bedroom not insulated | JOND | JOND | | BIN | T | 4492982 |
TUSCANY HOMES LLC | BIN | R | 03/22/2013 | need to insulate ceiling areas upstairs where they can't get to | JOND | JOND | | BIN | R | 4492238 |
TUSCANY HOMES LLC | BFR | C | 03/22/2013 | | JOND | JOND | | BFR | C | 4492237 |
TUSCANY HOMES LLC | BLA | C | 03/20/2013 | | JOND | JOND | | BLA | C | 4490428 |
TUSCANY HOMES LLC | BFR | R | 03/19/2013 | need T2 truss design showing extra weight of furnace on bottom cord / T1G girder has 916 of uplift one truss clip not enough / firestop gas line and wire hole / need 2-2x4's under T6g / bring down pt loads from upstairs to main level / fireblock garage brackets / need steel shims under beam at pocket / ok to insulate | JOND | JOND | | BFR | R | 4489883 |
TUSCANY HOMES LLC | BSP | P | 03/15/2013 | cantilever insulation OK; front porch fasteners OK | JIMP | JIMP | | BSP | P | 4487832 |
TUSCANY HOMES LLC | BFD | C | 01/23/2013 | | JOND | JOND | | BFD | C | 4458945 |
TUSCANY HOMES LLC | BFT | C | 01/23/2013 | engineer letter on file | JOND | JOND | | BFT | C | 4458944 |
TUSCANY HOMES LLC | BFN | C | 01/23/2013 | engineer letter on file / design, soils and open hole on file / drain usable area | JOND | JOND | | BFN | C | 4458943 |
TUSCANY HOMES LLC | BFN | P | 01/03/2013 | AUTHORIZED INSPECTION BY ENGINEER | KIM | KIM | KIM | BFN | P | 4448559 |
TUSCANY HOMES LLC | BFT | P | 01/03/2013 | AUTHORIZED INSPECTION BY ENGINEER | KIM | KIM | KIM | BFT | P | 4448558 |
PEAK AUDIO VIDEO INC | E= | C | 05/31/2013 | | MIKEC | MIKEC | | E= | C | 4534581 |
PEAK AUDIO VIDEO INC | E= | L | 05/30/2013 | | MIKEC | MIKEC | | E= | L | 4533576 |
PEAK AUDIO VIDEO INC | ES | C | 05/09/2013 | Residential Underground: NEW 200 AMP SERVICE | MIKEC | MIKEC | | ES | C | 4520987 |
PEAK AUDIO VIDEO INC | ER | C | 03/13/2013 | 3-20 1-15 #6AL----FINISHED BASEMENT---- | TIMA | TIMA | | ER | C | 4486411 |
PEAK AUDIO VIDEO INC | ES | R | 03/11/2013 | SEE ROUGH | TIMA | TIMA | | ES | R | 4484989 |
PEAK AUDIO VIDEO INC | ER | R | 03/11/2013 | CAN'T USE AL WIRE FOR RISER BOND,NEED NEUTRAL FOR 3-WAY SWITCH IN GARAGE,WIRE HANGING OUT OF CEILING IN MASTER HALL,INSTALL BASEMENT BATH FAN | TIMA | TIMA | | ER | R | 4484988 |
BRUNO'S HEATING & COOLING | H= | C | 06/06/2013 | Equipment certificate received and sent to scanning. | MICHAELS | MICHAELS | | H= | C | 4537616 |
BRUNO'S HEATING & COOLING | H= | P | 06/03/2013 | Duct leakage report received, need new equipment certificate stamped. Note: high/low in wall and full a/c on both systems. Secondary drain over upper bath window. | MICHAELS | MICHAELS | | H= | P | 4535213 |
WHITE BROS CUSTOM PLUMBING & HEATING | HC | C | 03/13/2013 | RELEASE METER | MICHAELS | MICHAELS | | HC | C | 4486431 |
WHITE BROS CUSTOM PLUMBING & HEATING | HI | C | 03/13/2013 | 10# test ok. 1 1/4" main to furn, w/h, fp, range, attic furnace. | MICHAELS | MICHAELS | | HI | C | 4486403 |
BRUNO'S HEATING & COOLING | HRR | C | 03/13/2013 | Duct design ok. Need equipment cert to match by final, basement furnace shown as 80% on plan and direct vent installed. Need duct leakage report on attic system also. Note: FB, no osa, a/c rough(coil and lineset on both systems) direct vent furnace in bsmt, 80% in attic. | MICHAELS | MICHAELS | | HRR | C | 4486390 |
WHITE BROS CUSTOM PLUMBING & HEATING | P= | C | 05/24/2013 | finished basement, no irrigation. | DICK | DICK | | P= | C | 4530200 |
WHITE BROS CUSTOM PLUMBING & HEATING | PTO | C | 03/04/2013 | | LEE | LEE | | PTO | C | 4481355 |
WHITE BROS CUSTOM PLUMBING & HEATING | PB | C | 01/30/2013 | | LYNNIE | LYNNIE | | PB | C | 4463814 |