C. R. SHEA HOMES, INC. | B= | C | 07/01/2013 | finished basement | JOND | JOND | | B= | C | 4554737 |
C. R. SHEA HOMES, INC. | BLA | C | 05/03/2013 | | JOND | JOND | | BLA | C | 4517080 |
C. R. SHEA HOMES, INC. | BIN | C | 04/08/2013 | | JOND | JOND | | BIN | C | 4501896 |
C. R. SHEA HOMES, INC. | BFR | C | 04/04/2013 | | JOND | JOND | | BFR | C | 4500290 |
C. R. SHEA HOMES, INC. | BSP | T | 04/03/2013 | PAID (REC#1121058): PLAN SPLICE FEE: $50 by: DALEH for Mechanical: splice to re configure duct layout | DALEH | DALEH | | BSP | T | 4499035 |
C. R. SHEA HOMES, INC. | BSP | P | 03/20/2013 | piers depth ok, will need to see rebar | JOND | JOND | | BSP | P | 4490598 |
C. R. SHEA HOMES, INC. | BSP | R | 03/19/2013 | no plans on site for deck piers | JOND | JOND | | BSP | R | 4489946 |
C. R. SHEA HOMES, INC. | BFI | C | 01/24/2013 | | JOND | JOND | | BFI | C | 4460208 |
C. R. SHEA HOMES, INC. | BFT | C | 01/24/2013 | engineer letter on file / full soils on file | JOND | JOND | | BFT | C | 4460207 |
C. R. SHEA HOMES, INC. | BFI | R | 01/23/2013 | need res check on site | JOND | JOND | | BFI | R | 4459186 |
C. R. SHEA HOMES, INC. | BFN | C | 01/23/2013 | engineer letter on file / design and open hole on file / need full soils | JOND | JOND | | BFN | C | 4459185 |
C. R. SHEA HOMES, INC. | BFT | P | 01/23/2013 | need engineer letter for footing inspection | JOND | JOND | | BFT | P | 4459182 |
C. R. SHEA HOMES, INC. | BFD | C | 01/23/2013 | | JOND | JOND | | BFD | C | 4459181 |
C. R. SHEA HOMES, INC. | BFN | P | 01/11/2013 | AUTHORIZED INSPECTION BY ENGINEER | MINDY | MINDY | MINDY | BFN | P | 4453177 |
C. R. SHEA HOMES, INC. | BFT | P | 01/11/2013 | AUTHORIZED INSPECTION BY ENGINEER | MINDY | MINDY | MINDY | BFT | P | 4453176 |
D & J QUALITY ELECTRIC INC | E= | C | 06/24/2013 | 20 AMP A.C | MIKEC | MIKEC | | E= | C | 4549425 |
D & J QUALITY ELECTRIC INC | ER | C | 04/02/2013 | | MIKEC | MIKEC | | ER | C | 4498413 |
D & J QUALITY ELECTRIC INC | ES | C | 04/01/2013 | Residential Underground: 200 amp service new res. | BRET | BRET | | ES | C | 4497728 |
D & J QUALITY ELECTRIC INC | ER | R | 04/01/2013 | seal holes where nm runs thru air return. note 8 cu to ovens, cooktop, hot tub 1/o to sub panel all in contact with insulation.. | BRET | BRET | | ER | R | 4497714 |
BRUNO'S HEATING & COOLING | H= | C | 06/28/2013 | Final complete. Note: mantel clearance ok, 6" osa to return added, full a/c. | MICHAELS | MICHAELS | | H= | C | 4553583 |
BRUNO'S HEATING & COOLING | HC | C | 04/04/2013 | RELEASE METER | MICHAELS | MICHAELS | | HC | C | 4500002 |
BRUNO'S HEATING & COOLING | HRR | C | 04/04/2013 | Duct design ok. Note: FB, no osa, a/c rough(coil and lineset), direct vent furnace. BY FINAL: install osa or change plan. | MICHAELS | MICHAELS | | HRR | C | 4500001 |
BRUNO'S HEATING & COOLING | HRR | T | 04/03/2013 | PAID (REC#1121186): Still no duct layout on site, will require 3rd trip. | MICHAELS | MICHAELS | | HRR | T | 4499136 |
BRUNO'S HEATING & COOLING | HRR | P | 04/02/2013 | No duct layout found, equipment cert ok. | MICHAELS | MICHAELS | | HRR | P | 4498424 |
ALPINE CREST PLBG. & HEATING INC. | HI | C | 04/01/2013 | 10# test ok. 1 1/4" main to furn, w/h, 2-fp, c-top, bbq. | MICHAELS | MICHAELS | | HI | C | 4497426 |
ALPINE CREST PLBG. & HEATING INC. | P= | C | 06/26/2013 | PLEASE INSTALL DOME STRAINER IN FLOOR SINK AND USE APPROVED PIPE FOR T&P (PVC NOT ALLOWED) --- NOTES FOR RBD --- HAS R.P. BACKFLOW FOR IRRIGATION | LEE | LEE | | P= | C | 4551782 |
ALPINE CREST PLBG. & HEATING INC. | PTO | C | 04/02/2013 | | LEE | LEE | | PTO | C | 4498589 |
ALPINE CREST PLBG. & HEATING INC. | PTO | P | 04/01/2013 | LOST / LOW TEST ON DWV -- NO TEST ON IRRIGATION -- BOCA / NAIL PLATES MISSING AT ICE-BOX, W/C H20, POWDER BATH AND BAR SINK STACK | LEE | LEE | | PTO | P | 4497731 |
ALPINE CREST PLBG. & HEATING INC. | PB | C | 01/30/2013 | | LYNNIE | LYNNIE | | PB | C | 4463819 |