HOMES BY MICHAEL HALL, LLC. | B= | C | 07/31/2013 | All other required Final inspections are complete. (This is a computer generated result) | JOND | JOND | | B= | C | 4574925 |
HOMES BY MICHAEL HALL, LLC. | B= | P | 07/30/2013 | Additional Inspections Required: External Agency Inspection F= by FIREDEPT is not Completed yet (Contact: 385-5982, x2). | JOND | JOND | | B= | P | 4574164 |
HOMES BY MICHAEL HALL, LLC. | B= | P | 07/26/2013 | Additional Inspections Required: External Agency Inspection F= by FIREDEPT is not Completed yet (Contact: 385-5982, x2), External Agency Inspection N= by ENGINEERING is not Completed yet (Contact: enijkamp@springsgov.com or 385-5977). need 1 1/2" clearance at handrail going downstairs / finished basement -- Schedule a new Building Final when above items are complete. | JOND | JOND | | B= | P | 4572354 |
HOMES BY MICHAEL HALL, LLC. | BFR | C | 05/20/2013 | engineer letter on file | JOND | JOND | | BFR | C | 4526877 |
HOMES BY MICHAEL HALL, LLC. | BIN | C | 05/20/2013 | | JOND | JOND | | BIN | C | 4526876 |
HOMES BY MICHAEL HALL, LLC. | BLA | C | 05/20/2013 | | JOND | JOND | | BLA | C | 4526870 |
HOMES BY MICHAEL HALL, LLC. | BFR | R | 05/15/2013 | brace off ends of laterals / need letter for header change at front / plans call for lsta 24 at trimmers at garage header / ok to insulate | JOND | JOND | | BFR | R | 4524087 |
HOMES BY MICHAEL HALL, LLC. | BSP | P | 04/24/2013 | PLAN SPLICE: (No Fee) by: DALEH for Mechanical: splice to add two heat runs in master | DALEH | DALEH | | BSP | P | 4511438 |
HOMES BY MICHAEL HALL, LLC. | BSP | P | 04/23/2013 | PLAN SPLICE: (No Fee) by: DALEH for Mechanical: splice to add two furnaces | DALEH | DALEH | | BSP | P | 4510600 |
HOMES BY MICHAEL HALL, LLC. | BSP | P | 04/22/2013 | narrow brace wall at garage ok | JOND | JOND | | BSP | P | 4509647 |
HOMES BY MICHAEL HALL, LLC. | BSP | P | 04/17/2013 | front porch ok | JOND | JOND | | BSP | P | 4507351 |
HOMES BY MICHAEL HALL, LLC. | BFI | C | 03/13/2013 | | JIMP | JIMP | | BFI | C | 4486524 |
HOMES BY MICHAEL HALL, LLC. | BFD | C | 03/13/2013 | drain usable space; isolate pads; float walls; 5% grade at final | JIMP | JIMP | | BFD | C | 4486522 |
HOMES BY MICHAEL HALL, LLC. | BFN | C | 03/13/2013 | engineers observation scanned in | JIMP | JIMP | | BFN | C | 4486519 |
HOMES BY MICHAEL HALL, LLC. | BFT | C | 03/13/2013 | engineers letter scanned in | JIMP | JIMP | | BFT | C | 4486512 |
WINTERS ELECTRIC, INC. | E= | C | 07/23/2013 | correction complete | CRAIGS | CRAIGS | | E= | C | 4569712 |
WINTERS ELECTRIC, INC. | E= | R | 07/22/2013 | receptacle in garage too low need 18" to bottom of box. 30 amp a/c wired | BRET | BRET | | E= | R | 4568914 |
WINTERS ELECTRIC, INC. | ES | C | 05/13/2013 | Residential Underground: new 200 amp service | MIKEC | MIKEC | | ES | C | 4522385 |
WINTERS ELECTRIC, INC. | ER | C | 05/13/2013 | sub panel rough in ok | MIKEC | MIKEC | | ER | C | 4522384 |
GENE'S HEATING AND AIR LLC | H= | C | 07/22/2013 | NOTES-- AC COMPLETE | JEFFL | JEFFL | | H= | C | 4568849 |
DOUBLE J GAS, INC. | HC | C | 05/14/2013 | RELEASE METER | MICHAELS | MICHAELS | | HC | C | 4523152 |
DOUBLE J GAS, INC. | HI | C | 05/14/2013 | 10# test ok. 1" main to 2- furn, w/h, fp. | MICHAELS | MICHAELS | | HI | C | 4523149 |
GENE'S HEATING AND AIR LLC | HRR | C | 05/14/2013 | Rough ok. Note:Duct design, FB, 6" osa on lower, a/c rough (coil and lineset) on upper, Direct vent furnace x2. | MICHAELS | MICHAELS | | HRR | C | 4523148 |
GENE'S HEATING AND AIR LLC | HRR | P | 05/13/2013 | Need new approved duct design on site, Re-inspect all. | MICHAELS | MICHAELS | | HRR | P | 4522278 |
UNIQUE RADIANT HTG. & PLBG. | P= | C | 07/18/2013 | HAS TWO PVB FOR IRRIGATION | LEE | LEE | | P= | C | 4566912 |
UNIQUE RADIANT HTG. & PLBG. | PTO | C | 05/13/2013 | | LEE | LEE | | PTO | C | 4522822 |
UNIQUE RADIANT HTG. & PLBG. | PB | C | 03/18/2013 | | MARTY | MARTY | | PB | C | 4488797 |