ARC VALLEY CONSTRUCTION, INC. | B= | C | 09/13/2013 | | JOND | JOND | | B= | C | 4604086 |
ARC VALLEY CONSTRUCTION, INC. | B= | P | 09/09/2013 | house numbers need to have a 1/2" stroke -- Schedule a new Building Final when above items are complete. | JOND | JOND | | B= | P | 4600519 |
ARC VALLEY CONSTRUCTION, INC. | B= | P | 08/30/2013 | Temp CO: building final partial ( Expires: 9/29/2013 12:00:00 AM) | NELIDA | NELIDA | | B= | P | 4596621 |
ARC VALLEY CONSTRUCTION, INC. | B= | P | 08/30/2013 | Additional Inspections Required: External Agency Inspection F= by FIREDEPT is not Completed yet (Contact: 385-5982, x2), External Agency Inspection N= by ENGINEERING is not Completed yet (Contact: enijkamp@springsgov.com or 385-5977), Electrical Final Inspection is not Completed yet, Mechanical Final Inspection is not Completed yet, Plumbing Final Inspection is not Completed yet. need all other finals signed off / need 5" house numbers with a 1/2" stroke / seal all penetration in garage / fix hole at back of house / can't have exposed foam insulation at west end of house / unfinished basement -- Schedule a new Building Final when above items are complete. | JOND | JOND | | B= | P | 4596061 |
ARC VALLEY CONSTRUCTION, INC. | BLA | C | 08/14/2013 | | JOND | JOND | | BLA | C | 4584931 |
ARC VALLEY CONSTRUCTION, INC. | BLA | R | 08/13/2013 | not done | JOND | JOND | | BLA | R | 4583951 |
ARC VALLEY CONSTRUCTION, INC. | BIN | C | 07/08/2013 | | JOND | JOND | | BIN | C | 4558393 |
ARC VALLEY CONSTRUCTION, INC. | BFR | C | 07/08/2013 | | JOND | JOND | | BFR | C | 4558389 |
ARC VALLEY CONSTRUCTION, INC. | BFR | R | 07/02/2013 | firestop throughout / 615 requires bolts or screws per design / 2 hts20 at 616 / 2 h2.5 at 617 and 618 / 3 hts20 614 / 3 2x12 header at back room / 3 ml header at front room / 4 2x6 under ml beam by stairs / 4 2x6 under beam at east end / shim and grout beam pocket / remove floating blocks / ok to insulate | JOND | JOND | | BFR | R | 4555573 |
ARC VALLEY CONSTRUCTION, INC. | BFD | C | 04/24/2013 | | JOND | JOND | | BFD | C | 4511250 |
ARC VALLEY CONSTRUCTION, INC. | BFD | R | 04/23/2013 | Need to drain around front entry way / Remove wood out of step downs | JOND | JOND | | BFD | R | 4510513 |
ARC VALLEY CONSTRUCTION, INC. | BFN | C | 04/10/2013 | | JOND | JOND | | BFN | C | 4503327 |
ARC VALLEY CONSTRUCTION, INC. | BFT | C | 04/09/2013 | already completed | JOND | JOND | | BFT | C | 4502670 |
ARC VALLEY CONSTRUCTION, INC. | BFT | C | 04/09/2013 | engineer letter on file | JOND | JOND | | BFT | C | 4502653 |
ARC VALLEY CONSTRUCTION, INC. | BFN | R | 04/09/2013 | missing ufer rod / design and soils on file / drain usable area | JOND | JOND | | BFN | R | 4502649 |
ARC VALLEY CONSTRUCTION, INC. | BFT | P | 04/08/2013 | Engineer of Record | TERRI | TERRI | | BFT | P | 4502091 |
MCDOWELL ELECTRIC COMPANY | E= | C | 08/30/2013 | | MIKEC | MIKEC | | E= | C | 4596534 |
MCDOWELL ELECTRIC COMPANY | E= | R | 08/29/2013 | WHIRLPOOL ACCESS, PROTECT FURNACE WIRE | MIKEC | MIKEC | | E= | R | 4595500 |
MCDOWELL ELECTRIC COMPANY | ES | C | 07/01/2013 | Residential Underground: NEW 200 AMP SERVICE | MIKEC | MIKEC | | ES | C | 4555167 |
MCDOWELL ELECTRIC COMPANY | ER | C | 06/26/2013 | | MIKEC | MIKEC | | ER | C | 4551642 |
MCDOWELL ELECTRIC COMPANY | ES | R | 06/26/2013 | NO GRC RISER OVER 10K | MIKEC | MIKEC | | ES | R | 4551640 |
R & R HEATING & AIR CONDITIONING, INC. | H= | C | 08/30/2013 | CORRECTION MADE | JERRYF | JERRYF | | H= | C | 4596204 |
R & R HEATING & AIR CONDITIONING, INC. | H= | P | 08/29/2013 | COMPLETE WATER HEATER FLUE TERMINATIONS - FURNACE FLUE TERMINATION INTAKE ONLY 4" ABOVE GRADE , REQUIRES 12" - REST OK. NOTES: FP NO MANTEL x 2 - FULL AC - UNFINISHED BASEMENT | JERRYF | JERRYF | | H= | P | 4595398 |
R & R HEATING & AIR CONDITIONING, INC. | HC | C | 07/01/2013 | RELEASE METER | MICHAELS | MICHAELS | | HC | C | 4554725 |
R & R HEATING & AIR CONDITIONING, INC. | HRR | C | 07/01/2013 | Fireplace and vent ok. | MICHAELS | MICHAELS | | HRR | C | 4554724 |
JOHNNY'S PLUMBING & HYDRONICS COMPANY | HI | C | 06/20/2013 | 10# test ok. 1 1/4" main to furn, on-demand w/h, c-top, bbq, fp. | MICHAELS | MICHAELS | | HI | C | 4547105 |
R & R HEATING & AIR CONDITIONING, INC. | HRR | P | 06/20/2013 | Rough ok pending fp install. Note: duct design, 6" osa to return, UB, a/c rough (coil and lineset), direct vent furnace. BY FINAL: splice osa onto plans. | MICHAELS | MICHAELS | | HRR | P | 4547104 |
R & R HEATING & AIR CONDITIONING, INC. | HRR | R | 06/18/2013 | NEED DUCT LAYOUT!! trip fee? | MICHAELS | MICHAELS | | HRR | R | 4545100 |
R & R HEATING & AIR CONDITIONING, INC. | HRR | P | 06/17/2013 | Need duct design on site for inspection. | MICHAELS | MICHAELS | | HRR | P | 4544177 |
JOHNNY'S PLUMBING & HYDRONICS COMPANY | P= | C | 09/06/2013 | ON DEMAND TANK-LESS W/H SET ON 120 DEGREES -- NO IRRIGATION WILL BE INSTALLED BLOCK WALL IN BACK YARD -- HAS PVB | LEE | LEE | | P= | C | 4600183 |
JOHNNY'S PLUMBING & HYDRONICS COMPANY | P= | R | 09/04/2013 | HOUSE OCCUPIED, NO ONE ANSWERED THE DOOR | LEE | LEE | | P= | R | 4598471 |
JOHNNY'S PLUMBING & HYDRONICS COMPANY | P= | P | 08/30/2013 | Need PVB installed and shower temperatures set. | JACK | JACK | | P= | P | 4596127 |
JOHNNY'S PLUMBING & HYDRONICS COMPANY | PTO | C | 06/21/2013 | | DICK | DICK | | PTO | C | 4547803 |
JOHNNY'S PLUMBING & HYDRONICS COMPANY | PTO | R | 06/20/2013 | not on test. | DICK | DICK | | PTO | R | 4546675 |
JOHNNY'S PLUMBING & HYDRONICS COMPANY | PB | P | 04/24/2013 | NO WATER SERVICE -- IF COMING THRU WALL HOLE NEEDS TO BE "SLEEVED" TWO PIPE SIZES LARGER THAN WATER SERVICE PER CODE -- NO CARD -- DWV OK | LEE | LEE | | PB | P | 4511734 |