BUILTRITE BUILDERS | B= | C | 08/13/2013 | | CHRISM | CHRISM | | B= | C | 4584197 |
BUILTRITE BUILDERS | BIN | C | 08/09/2013 | | CHRISM | CHRISM | | BIN | C | 4582147 |
BUILTRITE BUILDERS | BFR | P | 08/09/2013 | need stamped copy of eng letter for porch beam connections | CHRISM | CHRISM | | BFR | P | 4582107 |
BUILTRITE BUILDERS | BLA | C | 07/10/2013 | | CHRISM | CHRISM | | BLA | C | 4560005 |
BUILTRITE BUILDERS | BIN | P | 06/24/2013 | insulation ok, doors to decks not installed ok to start rock | CHRISM | CHRISM | | BIN | P | 4549257 |
BUILTRITE BUILDERS | BFR | P | 06/24/2013 | need eng letter for deck cover beam connetions | CHRISM | CHRISM | | BFR | P | 4549255 |
BUILTRITE BUILDERS | BFR | R | 06/11/2013 | ok to insulate, eng letter on file for framing changes and revisions, H2.5s at midbearing all three point trusses, roll block trusses above stairs and garage wall, bolt saddle at G05 girder, need eng connections for deck roof beams | CHRISM | CHRISM | | BFR | R | 4541040 |
BUILTRITE BUILDERS | BTR | C | 06/07/2013 | | CHRISM | CHRISM | | BTR | C | 4539083 |
BUILTRITE BUILDERS | BSP | P | 06/04/2013 | roof trusses, went over issues with framers missing hardware and laterals, need eng for truss bearing at garage front wall and header change at office window | CHRISM | CHRISM | | BSP | P | 4536549 |
BUILTRITE BUILDERS | BSP | P | 06/03/2013 | rear deck cover ok | CHRISM | CHRISM | | BSP | P | 4535418 |
BUILTRITE BUILDERS | BSP | P | 05/20/2013 | front porch framing ok | BLAKE | BLAKE | | BSP | P | 4527136 |
BUILTRITE BUILDERS | BSP | P | 05/20/2013 | front porch framing ok | BLAKE | BLAKE | | BSP | P | 4527135 |
BUILTRITE BUILDERS | BFI | C | 03/25/2013 | R-10 at walkout walls ok | CHRISM | CHRISM | | BFI | C | 4492980 |
BUILTRITE BUILDERS | BFD | P | 03/25/2013 | drain usable ok, need stamped copy of open hole | CHRISM | CHRISM | | BFD | P | 4492974 |
BUILTRITE BUILDERS | BFN | C | 03/25/2013 | design and eng report on file | CHRISM | CHRISM | | BFN | C | 4492961 |
BUILTRITE BUILDERS | BFT | C | 03/25/2013 | eng report on file | CHRISM | CHRISM | | BFT | C | 4492958 |
BUILTRITE BUILDERS | BFN | P | 03/14/2013 | AUTHORIZED INSPECTION BY ENGINEER | BPHILLIPS | BPHILLIPS | BPHILLIPS | BFN | P | 4487673 |
BUILTRITE BUILDERS | BFT | P | 03/14/2013 | AUTHORIZED INSPECTION BY ENGINEER | BPHILLIPS | BPHILLIPS | BPHILLIPS | BFT | P | 4487672 |
POSITIVE ELECTRIC, LLC | E= | C | 08/12/2013 | | MATTHEW | MATTHEW | | E= | C | 4583441 |
POSITIVE ELECTRIC, LLC | E= | R | 08/09/2013 | master porch outlet not gci protected ----------- master closet light needs to be enclosed ( center light ) -------------- double oven and sub panel needs to have lock able breakers ---------- both a/c 's ok 30 amp 40 amp | CRAIG | CRAIG | | E= | R | 4582251 |
POSITIVE ELECTRIC, LLC | ES | C | 06/10/2013 | Residential Underground: 200 amp 3/w: new res--------- meter is set; need seal | MATTHEW | MATTHEW | | ES | C | 4540155 |
POSITIVE ELECTRIC, LLC | ER | C | 06/10/2013 | finished basement, 100 amp sub-panel ok; check breakers at time of final------------ outlet in theater room still buried in bump out by raised floor; talked to contractor who will move outlet before final | MATTHEW | MATTHEW | | ER | C | 4540150 |
POSITIVE ELECTRIC, LLC | ES | R | 06/07/2013 | see rough | MATTHEW | MATTHEW | | ES | R | 4539231 |
POSITIVE ELECTRIC, LLC | ER | R | 06/07/2013 | where's the gas bond?, install ground screws for exterior lights, ground metal extension boxes at basement fireplace, outlet buried in theater room, outlet spacing in theater room, land nm at front outlet, 2/0 al on 200 amp feed thru to sub-panel----------- cabinets left of basement stairs per contractor----------- finished basement | MATTHEW | MATTHEW | | ER | R | 4539224 |
POSITIVE ELECTRIC, LLC | EUG | C | 04/01/2013 | 3/w 4/0 al | CRAIG | CRAIG | | EUG | C | 4497822 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | C | 08/09/2013 | OK NOTE A/C X 2 HI/LO TRANSFER AIR | DAVIDH | DAVIDH | | H= | C | 4582272 |
RIDGEVIEW PLUMBING | HC | C | 06/07/2013 | RELEASE METER | DAVIDH | DAVIDH | | HC | C | 4539124 |
RIDGEVIEW PLUMBING | HI | C | 06/07/2013 | CORRECTIONS MADE 10 LB TEST OK | DAVIDH | DAVIDH | | HI | C | 4539123 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | C | 06/07/2013 | OK NOTE EQUIP CHECK OK FINISHED BASEMENT 6" OSA FROM ATTIC | DAVIDH | DAVIDH | | HRR | C | 4539116 |
RIDGEVIEW PLUMBING | HI | P | 06/03/2013 | FIREPLACE MAIN FLOOR LIVING ROOM AREA INCOMPLETE --- USE PROPER GAUGE FOR TESTING -- FURNACE X-2, W/H X-2, F/P X-4, RANGE, BBQ, GARAGE HEATER | LEE | LEE | | HI | P | 4535270 |
RIDGEVIEW PLUMBING | P= | C | 08/09/2013 | TYPICAL PARADE HOME ? HAS TO HAVE INSPECTION TO MEET DEADLINE -- COMPLETED WITH THAT IN MIND -- HAS PVB FOR IRRIGATION | LEE | LEE | | P= | C | 4581912 |
RIDGEVIEW PLUMBING | PWO | C | 06/28/2013 | NO CARD | LEE | LEE | | PWO | C | 4553515 |
RIDGEVIEW PLUMBING | PTO | C | 06/03/2013 | 3" C/O ACCESS NEAR MEDIA ROOM IN COLUMN -- POT FILLER AND WALL MT. LAV ISOLATION VALVES AT FINAL | LEE | LEE | | PTO | C | 4535254 |
UNIQUE RADIANT HTG. & PLBG. | PB | C | 03/28/2013 | HDPE FROM WALL TO MECH. ROOM OK -- SERVICE THRU WALL LATER | LEE | LEE | | PB | C | 4495338 |