HOMEOWNER | B= | C | 10/15/2013 | All other required Final inspections are complete. (This is a computer generated result) | JOND | JOND | | B= | C | 4622960 |
HOMEOWNER | B= | P | 09/30/2013 | Additional Inspections Required: External Agency Inspection F= by FIREDEPT is not Completed yet (Contact: 385-5982, x2), External Agency Inspection PWO by CSUREVIEW is not Completed yet (Contact: 668-3524), External Agency Inspection PBS by CSUREVIEW is not Completed yet (Contact: 668-3524). finished basement | JOND | JOND | | B= | P | 4613035 |
HOMEOWNER | BFR | C | 07/15/2013 | | BLAKE | BLAKE | | BFR | C | 4563090 |
HOMEOWNER | BIN | C | 07/15/2013 | | BLAKE | BLAKE | | BIN | C | 4563089 |
HOMEOWNER | BIN | P | 07/10/2013 | insulation missing at bsmt west plumbing chase wall (same area as missing firestop) | BLAKE | BLAKE | | BIN | P | 4560434 |
HOMEOWNER | BFR | P | 07/10/2013 | 1- firestop missing at west bsmt furred plumbing wall and bsmt furred wall above shower pan area 2- west garage door overhead door bracket still needs solid block above and behind it (2 x 4 or 2 x 6 will do) 3- bsmt stair landing beam still presently supported at both ends by a floating wall 4- doesn't appear additional deck ledger lags have been installed | BLAKE | BLAKE | | BFR | P | 4560429 |
HOMEOWNER | BFR | R | 07/02/2013 | firestop throughout / fireblock garage brackets / need to support stair landing beam / deck ledger calls for 3 lags / ok to insulate | JOND | JOND | | BFR | R | 4555666 |
HOMEOWNER | BSP | P | 06/05/2013 | deck piers ok | JOND | JOND | | BSP | P | 4537127 |
HOMEOWNER | BFD | C | 04/26/2013 | | JOND | JOND | | BFD | C | 4512703 |
HOMEOWNER | BFI | C | 04/26/2013 | | JOND | JOND | | BFI | C | 4512702 |
HOMEOWNER | BFD | P | 04/23/2013 | Drain ok / Need walk out insulation / Soils on file | JOND | JOND | | BFD | P | 4510550 |
HOMEOWNER | BFN | C | 04/10/2013 | design and open hole letter on file / usable drain / ufer rod in / need full soils at drain | JOND | JOND | | BFN | C | 4503375 |
HOMEOWNER | BFT | C | 04/05/2013 | | JOND | JOND | | BFT | C | 4500945 |
D & J QUALITY ELECTRIC INC | E= | C | 09/25/2013 | 20 AMP A.C | MIKEC | MIKEC | | E= | C | 4610397 |
D & J QUALITY ELECTRIC INC | E= | R | 09/24/2013 | a.c not breakered in panel | MIKEC | MIKEC | | E= | R | 4609766 |
D & J QUALITY ELECTRIC INC | E= | R | 06/26/2013 | CANCELLED BY CONTRACTOR | MIKEC | MIKEC | | E= | R | 4551476 |
D & J QUALITY ELECTRIC INC | ES | C | 06/25/2013 | Residential Underground: NEW 200 AMP SERVICE | MIKEC | MIKEC | | ES | C | 4549973 |
D & J QUALITY ELECTRIC INC | ES | R | 06/24/2013 | I THINK THE WATER ENTRY POINT IS ON THE WEST EXTERIOR WALL NOT IN MECH ROOM | MIKEC | MIKEC | | ES | R | 4549502 |
D & J QUALITY ELECTRIC INC | ES | R | 06/21/2013 | NEED GROUND TO WATER SERVICE | MIKEC | MIKEC | | ES | R | 4548410 |
D & J QUALITY ELECTRIC INC | ER | C | 06/21/2013 | | MIKEC | MIKEC | | ER | C | 4548401 |
ARROW HAWK HEATING, LLC | H= | C | 09/24/2013 | ALL OK. NOTES: FULL AC - FP NO MANTEL AT THIS TIME - LOUVERED DOOR TO MECH WITH OPEN STAIRWELL | JERRYF | JERRYF | | H= | C | 4610015 |
ARROW HAWK HEATING, LLC | HC | C | 06/25/2013 | RELEASE METER | MICHAELS | MICHAELS | | HC | C | 4550031 |
ARROW HAWK HEATING, LLC | HRR | C | 06/25/2013 | Rough ok. Note: duct design, FB, 6" osa to return, a/c rough (coil and lineset), direct vent furnace, indirect w/h. | MICHAELS | MICHAELS | | HRR | C | 4550030 |
O.M.A.G.M., INC. | HI | C | 06/13/2013 | 10# test ok. 1" main to furn, w/h, range, fp. | MICHAELS | MICHAELS | | HI | C | 4542682 |
HOGAN MECHANICAL, INC. | P= | C | 09/26/2013 | | LEE | LEE | | P= | C | 4611844 |
HOGAN MECHANICAL, INC. | PTO | C | 06/26/2013 | | LEE | LEE | | PTO | C | 4551900 |
HOGAN MECHANICAL, INC. | PTO | P | 06/25/2013 | PEX NOT ALLOWED FOR WATER SERVICE PIPING PER CSU -- WATER SERVICE LACKS SLEEVE THRU FOUNDATION WALL (SEE 305.5 IPC) -- ICE MAKER BOX IN 2X4 EXTERIOR WALL | LEE | LEE | | PTO | P | 4550756 |
HOGAN MECHANICAL, INC. | PTO | R | 06/24/2013 | MASTER TUB AND SHOWER DRAIN NOT TIED IN | JOEL | JOEL | | PTO | R | 4548958 |
HOGAN MECHANICAL, INC. | PB | C | 05/03/2013 | | LEE | LEE | | PB | C | 4517427 |