SADDLETREE INC. | B= | C | 12/31/2013 | insulation certificate on file | JOND | JOND | | B= | C | 4664558 |
SADDLETREE INC. | B= | P | 12/30/2013 | need insulation certificate / finished basement -- Schedule a new Building Final when above items are complete. | JOND | JOND | | B= | P | 4664181 |
SADDLETREE INC. | BLA | C | 10/08/2013 | | JOND | JOND | | BLA | C | 4618724 |
SADDLETREE INC. | BFR | C | 09/12/2013 | | JOND | JOND | | BFR | C | 4603396 |
SADDLETREE INC. | BFR | R | 09/10/2013 | laterals missing at A8, L5 / nail gusset plate on L5 / 2-h2.5's at E1 / 3 kings at window in back of garage / shoot down t-posts / remove floating blocks in movie room / ok to insulate | JOND | JOND | | BFR | R | 4602053 |
SADDLETREE INC. | BIN | P | 09/10/2013 | Qualified third party energy inspection documentation must be presented at time of final building (B=) inspection | INTERNET | INTERNET | | BIN | P | 4601320 |
SADDLETREE INC. | BSP | P | 09/04/2013 | front and rear porch posts ok | JOND | JOND | | BSP | P | 4598176 |
SADDLETREE INC. | BTR | C | 08/19/2013 | | JOND | JOND | | BTR | C | 4587979 |
SADDLETREE INC. | BSP | T | 08/01/2013 | PAID (REC#1145920) PLAN SPLICE FEE: $50 by: TCRIPPEN for Mechanical: Changed insulation values for theater room | TCRIPPEN | TCRIPPEN | | BSP | T | 4576880 |
SADDLETREE INC. | BTR | R | 07/31/2013 | need to finish ridge boards and need to be wrapped | JOND | JOND | | BTR | R | 4575234 |
SADDLETREE INC. | BFD | C | 05/07/2013 | | JOND | JOND | | BFD | C | 4519000 |
SADDLETREE INC. | BFI | C | 05/07/2013 | | JOND | JOND | | BFI | C | 4518994 |
SADDLETREE INC. | BFN | C | 05/07/2013 | engineer letter on file / design and soils on file / drain usable area | JOND | JOND | | BFN | C | 4518993 |
SADDLETREE INC. | BFT | C | 05/07/2013 | engineer letter on file | JOND | JOND | | BFT | C | 4518989 |
SADDLETREE INC. | BFD | P | 05/06/2013 | drains ok, need footer and foundation signed off / soils on file / usable drain | JOND | JOND | | BFD | P | 4518029 |
SADDLETREE INC. | BFI | R | 05/06/2013 | no res check on site | JOND | JOND | | BFI | R | 4518026 |
SADDLETREE INC. | BFN | P | 04/11/2013 | AUTHORIZED INSPECTION BY ENGINEER | KIM | KIM | KIM | BFN | P | 4504605 |
SADDLETREE INC. | BFT | P | 04/11/2013 | AUTHORIZED INSPECTION BY ENGINEER | KIM | KIM | KIM | BFT | P | 4504604 |
D & J QUALITY ELECTRIC INC | E= | C | 12/26/2013 | 1-30 1-40 AMP A.C'S | MIKEC | MIKEC | | E= | C | 4662851 |
D & J QUALITY ELECTRIC INC | ES | C | 09/03/2013 | Residential Underground: NEW 150 AMP SERVICE | MIKEC | MIKEC | | ES | C | 4597352 |
D & J QUALITY ELECTRIC INC | ER | C | 09/03/2013 | CEILING FAN BOX MISSING IN GREAT ROOM, OUTLET BOX MISSING DOWNSTAIRS BY FIREPLACE. PARTIAL BASEMENT FINISH | MIKEC | MIKEC | | ER | C | 4597342 |
OLYMPIA HEATING & COOLING INC. | H= | C | 12/12/2013 | OK NOTES: A/C INSTALLED ON BOTH UNITS | KEITHW | KEITHW | | H= | C | 4655909 |
OLYMPIA HEATING & COOLING INC. | HC | C | 09/09/2013 | RELEASE METER | JERRYF | JERRYF | | HC | C | 4600863 |
OLYMPIA HEATING & COOLING INC. | HRR | C | 09/09/2013 | CHECK VENTILATION DAMPER IN CEILING OF BATH #4 AT BEDROOM 3$ AT FINAL - REST OK. NOTES: FINISHED BASEMENT - HIGH / LOW GRILLES TO MECH / LOW WALL GRILLE IS BY STAIRS | JERRYF | JERRYF | | HRR | C | 4600841 |
OLYMPIA HEATING & COOLING INC. | HRR | P | 09/06/2013 | SEAL DUCT AT BEDROOM 4 CLOSET - NEED DAMPER AND ACCESS PANEL AT VENTILATION AIR - WHAT IS METAL PANNING IN JOIST SPACE IN RECROOM BY MECH - REST OK. NOTES: FURNACE OK - FINISHED BASEMENT - 2 FP FRAMING OK - 2 AC ROUGHS | JERRYF | JERRYF | | HRR | P | 4599939 |
KAMPP-L ENTERPRISES, INC. | HI | C | 07/29/2013 | 10# OK. Notes: 2" main - 2 furn - 2 wh - 2 fp - 2 future unit heaters - firepit - bbq - ckt Total design 150' good for 928000 btu | JERRYF | JERRYF | | HI | C | 4573541 |
KAMPP-L ENTERPRISES, INC. | P= | C | 11/26/2013 | pvb installed | TIM | TIM | | P= | C | 4648037 |
KAMPP-L ENTERPRISES, INC. | P= | T | 11/25/2013 | PAID (REC#1168322): not ready no water | TIM | TIM | | P= | T | 4647254 |
KAMPP-L ENTERPRISES, INC. | PTO | C | 08/07/2013 | | LEE | LEE | | PTO | C | 4580725 |
KAMPP-L ENTERPRISES, INC. | PTO | R | 08/05/2013 | not ready, waived trip fee. | DICK | DICK | | PTO | R | 4578059 |
KAMPP-L ENTERPRISES, INC. | PB | C | 05/14/2013 | | LEE | LEE | | PB | C | 4523676 |