MAJESTIC CUSTOM HOMES, INC. | B= | C | 10/11/2013 | All other required Final inspections are complete. (This is a computer generated result) | JOND | JOND | | B= | C | 4620714 |
MAJESTIC CUSTOM HOMES, INC. | B= | P | 10/10/2013 | Additional Inspections Required: External Agency Inspection F= by FIREDEPT is not Completed yet (Contact: 385-5982, x2). finished basement | JOND | JOND | | B= | P | 4620140 |
MAJESTIC CUSTOM HOMES, INC. | BSP | P | 10/07/2013 | deck framing ok | JOND | JOND | | BSP | P | 4617686 |
MAJESTIC CUSTOM HOMES, INC. | BSP | P | 09/30/2013 | deck piers ok | JOND | JOND | | BSP | P | 4613013 |
MAJESTIC CUSTOM HOMES, INC. | BSP | T | 09/23/2013 | PAID (REC#1155397) PLAN SPLICE FEE: $50 by: MICHAEL for Construction: Add deck | MICHAELA | MICHAELA | | BSP | T | 4608614 |
MAJESTIC CUSTOM HOMES, INC. | BIN | C | 08/16/2013 | | JOND | JOND | | BIN | C | 4587384 |
MAJESTIC CUSTOM HOMES, INC. | BIN | R | 08/15/2013 | Fiere block garage door bracket, need 1.5" all the way around / Remove combustables from B-vent chase / Air barrier in kitchen window not adequately fastened | JEREMYA | JEREMYA | | BIN | R | 4586132 |
MAJESTIC CUSTOM HOMES, INC. | BFR | C | 08/15/2013 | Corrections from previous inspection complete | JEREMYA | JEREMYA | | BFR | C | 4586131 |
MAJESTIC CUSTOM HOMES, INC. | BFR | R | 08/13/2013 | need to brace off ends of laterals above living room at a 45 degree / need to firestop vent chase by stairs / ok to insulate | JOND | JOND | | BFR | R | 4584431 |
MAJESTIC CUSTOM HOMES, INC. | BFR | R | 08/09/2013 | 1) strap master bath plumbing wall studs 2) missing 3-2x4 post under master bath 9 1/2" ml center and missing crush block below and posts to foundation and at ends of ml 3) vault master bedroom strap peak and ls40 rake corners 4) restraint ends of lateral bracing over living room entry both ends 5) fire stop "B" vent at attic and 10'up and wood fire place, hole and cannot use celetex 6) missing crush block under living room header at rim 7) need face hangers and fill web at headered off joist under master tub | DANF | DANF | | BFR | R | 4582412 |
MAJESTIC CUSTOM HOMES, INC. | BSP | T | 08/08/2013 | PAID (REC#1147170) ADDITIONAL PLAN REVIEW TIME: $50 From: JIMA ? added larger frieplace cantilever to rear of house
| JIMA | JIMA | | BSP | T | 4581378 |
MAJESTIC CUSTOM HOMES, INC. | BLA | C | 08/05/2013 | | JOND | JOND | | BLA | C | 4578221 |
MAJESTIC CUSTOM HOMES, INC. | BSP | P | 07/23/2013 | shear ok | JOND | JOND | | BSP | P | 4569247 |
MAJESTIC CUSTOM HOMES, INC. | BSP | P | 07/17/2013 | shear ok | JOND | JOND | | BSP | P | 4565694 |
MAJESTIC CUSTOM HOMES, INC. | BSP | P | 07/15/2013 | "shear" inspection- assume windbracing- numerous staples are over-driven and penetrate half way through structural panels | BLAKE | BLAKE | | BSP | P | 4563233 |
MAJESTIC CUSTOM HOMES, INC. | BSP | P | 07/03/2013 | front porch and post ok | JOND | JOND | | BSP | P | 4556538 |
MAJESTIC CUSTOM HOMES, INC. | BFT | C | 05/01/2013 | engineer letter on file | JOND | JOND | | BFT | C | 4515410 |
MAJESTIC CUSTOM HOMES, INC. | BFN | C | 05/01/2013 | engineer letter on file / design, soils and open hole on file / drain usable area | JOND | JOND | | BFN | C | 4515403 |
MAJESTIC CUSTOM HOMES, INC. | BFD | C | 05/01/2013 | | JOND | JOND | | BFD | C | 4515402 |
MAJESTIC CUSTOM HOMES, INC. | BFN | P | 04/12/2013 | AUTHORIZED INSPECTION BY ENGINEER | BPHILLIPS | BPHILLIPS | BPHILLIPS | BFN | P | 4505182 |
MAJESTIC CUSTOM HOMES, INC. | BFT | P | 04/12/2013 | AUTHORIZED INSPECTION BY ENGINEER | BPHILLIPS | BPHILLIPS | BPHILLIPS | BFT | P | 4505181 |
PEAK ELECTRIC INC. | E= | C | 10/09/2013 | CORRECTIONS MADE | BRIAN | BRIAN | | E= | C | 4619659 |
PEAK ELECTRIC INC. | E= | R | 10/08/2013 | BATH LIGHTING BREAKER TRIPPING------ NOTES -- FINISHED BASEMENT-- AC PRE WIRE | BRIAN | BRIAN | | E= | R | 4618611 |
PEAK ELECTRIC INC. | ES | C | 07/15/2013 | Residential Underground: NEW 150 AMP SERVICE | MIKEC | MIKEC | | ES | C | 4562860 |
PEAK ELECTRIC INC. | ER | C | 07/15/2013 | | MIKEC | MIKEC | | ER | C | 4562859 |
PEAK ELECTRIC INC. | ES | L | 07/12/2013 | | MIKEC | MIKEC | | ES | L | 4562449 |
PEAK ELECTRIC INC. | ER | L | 07/12/2013 | | MIKEC | MIKEC | | ER | L | 4562448 |
BRUNO'S HEATING & COOLING | H= | C | 09/30/2013 | CORRECTIONS MADE | JERRYF | JERRYF | | H= | C | 4613403 |
BRUNO'S HEATING & COOLING | H= | P | 09/26/2013 | SEAL HOLE AT EXTERIOR FOR LINE SET - MISSING SUPPLY IN BASEMENT BEDROOM - RECONNECT WATER HEATER FLUE - NEED TO CONFIRM DRYER TRANSFER - REST OK. NOTES: FULL AC - NO FP MANTEL AT THIS TIME - NO CARPET AT THIS TIME | JERRYF | JERRYF | | H= | P | 4611627 |
BRUNO'S HEATING & COOLING | H= | R | 09/25/2013 | ALL LOCKED UP -- TRIP-FEE ?? | LEE | LEE | | H= | R | 4610936 |
DOUBLE J GAS, INC. | HC | C | 07/18/2013 | RELEASE METER | JERRYF | JERRYF | | HC | C | 4566483 |
DOUBLE J GAS, INC. | HI | C | 07/18/2013 | 10# OK . Notes: 11/4" Main - furn -2 wh - ckt - Total load 460000 btu - 60' design | JERRYF | JERRYF | | HI | C | 4566475 |
BRUNO'S HEATING & COOLING | HRR | C | 07/16/2013 | No fireplace installed at this time. Rest OK. Notes: duct and furnace ok - finished basement - coil and lineset - no osa shown on duct design | JERRYF | JERRYF | | HRR | C | 4563859 |
PACIFIC PLUMBING, INCORPORATED | P= | C | 10/09/2013 | PVB INSTALLED. | DICK | DICK | | P= | C | 4619288 |
PACIFIC PLUMBING, INCORPORATED | PTO | C | 07/15/2013 | | LEE | LEE | | PTO | C | 4563476 |
PACIFIC PLUMBING, INCORPORATED | PB | C | 05/09/2013 | | LEE | LEE | | PB | C | 4521036 |