TIFFANY HOMES, LLC. | B= | C | 11/21/2013 | All other required Final inspections are complete. (This is a computer generated result) | JOND | JOND | | B= | C | 4645927 |
TIFFANY HOMES, LLC. | B= | P | 11/20/2013 | Additional Inspections Required: External Agency Inspection F= by FIREDEPT is not Completed yet (Contact: 385-5982, x2). | JOND | JOND | | B= | P | 4645597 |
TIFFANY HOMES, LLC. | B= | P | 11/13/2013 | Additional Inspections Required: External Agency Inspection F= by FIREDEPT is not Completed yet (Contact: 385-5982, x2). need to finish stone fireplace on the outside or atleast get it brown coated / finished basement -- Schedule a new Building Final when above items are complete. | JOND | JOND | | B= | P | 4640965 |
TIFFANY HOMES, LLC. | BLA | C | 09/06/2013 | | JOND | JOND | | BLA | C | 4599705 |
TIFFANY HOMES, LLC. | BFR | C | 08/12/2013 | Engineer letters on file | JOND | JOND | | BFR | C | 4583075 |
TIFFANY HOMES, LLC. | BIN | C | 08/12/2013 | | JOND | JOND | | BIN | C | 4583074 |
TIFFANY HOMES, LLC. | BFR | P | 08/08/2013 | Engineering for truss web repairs on file / Missing doors and windows throughout, house not dried in / Fire block garage door brackets / Engineer letter for gusset repair on L1 truss, letters provided do not address / Add roll blocks at the tops of mono trusses / Add bracing on G1E, bracing to be 48" O.C. where gable is taller than 6' / Web 5-10 on Truss G7 appears to be damaged / Missing lateral bracing on G10 / Add straps on top plates in upstairs bathroom and A35's at corners / Add (2) 2x6 post under D1 truss / Plans call out both a 3" AND a 4" non adjustable post at fireplace in basement / Missing ST18 straps on paralam post / The letter provided for moving paralam post is for moving 6", post has been moved 3', provide new letter / Insulate at own risk, due to missing doors and windows | JEREMYA | JEREMYA | | BFR | P | 4581393 |
TIFFANY HOMES, LLC. | BSP | P | 07/18/2013 | front and rear porches ok | JOND | JOND | | BSP | P | 4566294 |
TIFFANY HOMES, LLC. | BSP | P | 07/10/2013 | deck footer holes (4) ok | BLAKE | BLAKE | | BSP | P | 4560671 |
TIFFANY HOMES, LLC. | BFT | C | 05/24/2013 | engineer letter on file | JOND | JOND | | BFT | C | 4530544 |
TIFFANY HOMES, LLC. | BFD | C | 05/24/2013 | | JOND | JOND | | BFD | C | 4530543 |
TIFFANY HOMES, LLC. | BFN | C | 05/24/2013 | engineer letter on file / design, soils and open hole on file / drain usable area | JOND | JOND | | BFN | C | 4530542 |
D & J QUALITY ELECTRIC INC | E= | C | 11/07/2013 | | MIKEC | MIKEC | | E= | C | 4637344 |
D & J QUALITY ELECTRIC INC | E= | R | 11/06/2013 | NO WHIRLPOOL ACCESS----------------- 1-20 AMP, 1-40 AMP A.C'S | MIKEC | MIKEC | | E= | R | 4636780 |
D & J QUALITY ELECTRIC INC | ES | C | 08/05/2013 | Residential Underground: NEW 200 AMP SERVICE | MIKEC | MIKEC | | ES | C | 4578788 |
D & J QUALITY ELECTRIC INC | ER | C | 08/05/2013 | | MIKEC | MIKEC | | ER | C | 4578787 |
BRUNO'S HEATING & COOLING | H= | C | 11/08/2013 | OK NOTES: WILL SCAN DUCT LEAKAGE REPORT, 3-DIRECT VENT FURNACES, LOUVER DOOR, ONE UNIT LOCATED IN ATTIC, A/C INSTALLED ON TWO UNITS | KEITHW | KEITHW | | H= | C | 4638495 |
BRUNO'S HEATING & COOLING | H= | P | 11/07/2013 | NEED LADDER TO ACCESS ATTIC, NEED DUCT LEAKAGE REPORTS NOTES: A/C INSTALLED ON BOTH UNITS | KEITHW | KEITHW | | H= | P | 4637473 |
BRUNO'S HEATING & COOLING | HRR | C | 08/07/2013 | CORRECTIONS MADE | JERRYF | JERRYF | | HRR | C | 4580478 |
BRUNO'S HEATING & COOLING | HC | C | 08/06/2013 | RELEASE METER | JERRYF | JERRYF | | HC | C | 4579434 |
BRUNO'S HEATING & COOLING | HRR | P | 08/06/2013 | OPEN FRAMING AT DINING ROOM FIREPLACE TO VERIFY FLUE CLEARANCE - LEAK TEST BY FINAL - REST OK. NOTES: DUCT AND FURNACES GOOD - 2 AC COIL AND LINESETS - FINISHED BASEMENT - 6" OSA TO ATTIC FURNACE | JERRYF | JERRYF | | HRR | P | 4579424 |
BRUNO'S HEATING & COOLING | HRR | P | 08/05/2013 | STOPPED INSPECTION, REINSPECT ALL. ITEMS FOUND: MAIN FLOOR: FRAME AROUND DRYER VENT. DURA VENT TOUCHING THERMOPLY IN CEILING. NEED 1 INCH CLEARANCE FROM B-VENT TO WOOD. SEAL RETURN AIR HEADER IN DINING ROOM. UPPER FLOOR: FRAME AROUND DURAVENT. LEAKAGE TEST FOR ATTIC DUCTS? REMOVE SAGS FROM FLEX DUCTS. SORRY BUT NEED LADDER TO VERIFY OUTSIDE AIR AND FURNACE SIZING. BASEMENT: COMPLETELY FRAME FIREPLACE. ALTHOUGH DUCT DESIGN IS ALLOWED TO BE SUBMITTED ON 8 1/2 X 11 PAPER, DESIGN IS TO BE LARGE ENOUGH TO FILL PAPER, NOT TO BE 1/2 THE SIZE OF THE PAGE. | NANCY | NANCY | | HRR | P | 4578614 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | HI | C | 08/01/2013 | 10# OK. NOTES: 11/4" MAIN - 3 FURNACES - 2 FP - CKT - WH | JERRYF | JERRYF | | HI | C | 4576427 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | P= | C | 11/12/2013 | | TIM | TIM | | P= | C | 4639101 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | PTO | C | 08/01/2013 | | LEE | LEE | | PTO | C | 4576869 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | PB | C | 06/03/2013 | | LEE | LEE | | PB | C | 4535754 |