ELITE PROPERTIES OF AMERICA, INC. | B= | C | 09/26/2013 | | DANF | DANF | | B= | C | 4611189 |
ELITE PROPERTIES OF AMERICA, INC. | B= | P | 09/25/2013 | egress ladder not attached -- Schedule a new Building Final when above items are complete. | DANF | DANF | | B= | P | 4610595 |
ELITE PROPERTIES OF AMERICA, INC. | B= | P | 09/23/2013 | Additional Inspections Required: External Agency Inspection N= by ENGINEERING is not Completed yet (Contact: enijkamp@springsgov.com or 385-5977). need ladder to check attic insulation / all egress ladders need to be permanently fastened to window well. -- Schedule a new Building Final when above items are complete. | JEREMYC | JEREMYC | | B= | P | 4608860 |
ELITE PROPERTIES OF AMERICA, INC. | BLA | C | 07/29/2013 | | DANF | DANF | | BLA | C | 4573557 |
ELITE PROPERTIES OF AMERICA, INC. | BIN | C | 07/18/2013 | | DANF | DANF | | BIN | C | 4566853 |
ELITE PROPERTIES OF AMERICA, INC. | BFR | C | 07/16/2013 | | DANF | DANF | | BFR | C | 4564428 |
ELITE PROPERTIES OF AMERICA, INC. | BSP | P | 06/28/2013 | front and rear porch framing OK to cover | DANF | DANF | | BSP | P | 4554029 |
ELITE PROPERTIES OF AMERICA, INC. | BFD | C | 05/23/2013 | | DANF | DANF | | BFD | C | 4529954 |
ELITE PROPERTIES OF AMERICA, INC. | BFN | C | 05/20/2013 | foundation design and compaction tests and open excavation on file; Ufer OK | DANF | DANF | | BFN | C | 4526963 |
ELITE PROPERTIES OF AMERICA, INC. | BFT | C | 05/14/2013 | pads OK; ISO, float, 5% slope from foundation, drain usable; over dig | DANF | DANF | | BFT | C | 4523208 |
FOUNTAIN VALLEY ELECTRICAL, LLC | E= | C | 09/18/2013 | double oven / cook top not installed at time of final | CRAIG | CRAIG | | E= | C | 4606221 |
FOUNTAIN VALLEY ELECTRICAL, LLC | E= | R | 09/12/2013 | missing 2 floor outlet ( hard wood floor and carpet upstairs ) -------------- missing lights front of garage and pendant in kitchen --------------- arc shield for kitchen outlets ----------- no power to kitchen outlets --------------- inside front door light not working ------------ no a/c or rough | CRAIG | CRAIG | | E= | R | 4603284 |
FOUNTAIN VALLEY ELECTRICAL, LLC | ER | C | 07/11/2013 | 150 amp 3/w 1-#6 al 1-15 amp MCC 1-20 amp MCC | TOMC | TOMC | | ER | C | 4561586 |
FOUNTAIN VALLEY ELECTRICAL, LLC | ES | C | 07/11/2013 | Residential Underground: 150 amp 3/w ok 22k main breaker needs meter abnd reseal | TOMC | TOMC | | ES | C | 4561585 |
REGIONAL HEATING AND AIR CONDITIONING, INC. | H= | C | 09/20/2013 | Corrections made. Note: full a/c. | MICHAELS | MICHAELS | | H= | C | 4608119 |
REGIONAL HEATING AND AIR CONDITIONING, INC. | H= | P | 09/06/2013 | B-vent cap missing,Electrical disconnect will be blocked by downdraft duct when installed under cooktop, Rest ok. Note: UB, a/c rough(coil and lineset). | MICHAELS | MICHAELS | | H= | P | 4599934 |
REGIONAL HEATING AND AIR CONDITIONING, INC. | HC | C | 07/12/2013 | RELEASE METER | MICHAELS | MICHAELS | | HC | C | 4562517 |
REGIONAL HEATING AND AIR CONDITIONING, INC. | HRR | C | 07/12/2013 | Rough ok. Note: duct design, 6" osa, UB, a/c rough(coil and lineset), direct vent furnace. | MICHAELS | MICHAELS | | HRR | C | 4562512 |
KAMPP-L ENTERPRISES, INC. | HI | C | 07/08/2013 | 10 LB TEST OK NOTE 1 1/4" 1 FURN,W/H,F/P,CT,AND BBQ | DAVIDH | DAVIDH | | HI | C | 4558106 |
KAMPP-L ENTERPRISES, INC. | P= | C | 09/03/2013 | unfinished basement, 3/4'' pvb installed | TED | TED | | P= | C | 4597308 |
KAMPP-L ENTERPRISES, INC. | PTO | C | 07/09/2013 | | LEE | LEE | | PTO | C | 4559328 |
KAMPP-L ENTERPRISES, INC. | PTO | P | 07/08/2013 | FUTURE BASEMENT BAR SINK LACKS A VENT ? -- REST OK | LEE | LEE | | PTO | P | 4558506 |
KAMPP-L ENTERPRISES, INC. | PB | C | 06/03/2013 | | LEE | LEE | | PB | C | 4535399 |