ROBERT SCOTT GENERAL CONTRACTORS, INC. | B= | C | 10/16/2013 | unfinished basement | JOND | JOND | | B= | C | 4623478 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BFR | C | 08/19/2013 | | JOND | JOND | | BFR | C | 4587870 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BIN | C | 08/19/2013 | | JOND | JOND | | BIN | C | 4587865 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BSP | T | 08/16/2013 | PAID (REC#1148672) ADDITIONAL PLAN REVIEW TIME: $50 From: DALEH splice | DALEH | DALEH | | BSP | T | 4587165 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BFR | P | 08/15/2013 | Missing lateral brace on A6 / Add gable bracing at gable ends over 6' @ 48" O.C. / Missing all roll blocking / Add A35 at inside corner of master bedroom and add strap at peak of South wall / Shim header in NE bedroom upstairs / Add 2x6 under LVL at fireplace for full bearing / Missing LSU 26's @ fireplace / Add (3) 2x6 post under LVL at stair landing / Need nails at corner bracket @ basement stairs / Missing blocking above common wall / Missing point loads under fireplace and at garage wall / Attach column to lvl at bottom of stairs / Cross brace steel beam in open beam pocket / OK to insulate, DO NOT COVER POINT LOADS! / Engineering on file for roof truss changes and for post change in basement. | JEREMYA | JEREMYA | | BFR | P | 4585955 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BLA | C | 08/15/2013 | | JEREMYA | JEREMYA | | BLA | C | 4585944 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BFD | C | 06/17/2013 | | JOND | JOND | | BFD | C | 4544213 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BFN | C | 06/12/2013 | design and soils on file / drain usable area / ufer rod in | JOND | JOND | | BFN | C | 4541690 |
ROBERT SCOTT GENERAL CONTRACTORS, INC. | BFT | C | 06/03/2013 | footer and pads are good. | BLAKE | BLAKE | | BFT | C | 4535497 |
SERVICE FIRST ELECTRIC | E= | C | 10/09/2013 | `CORRECTIONS MADE | BRIAN | BRIAN | | E= | C | 4619658 |
SERVICE FIRST ELECTRIC | E= | R | 10/08/2013 | NEED AFCI BREAKER ON KITCHEN CIRCUIT THAT FEEDS DINING ROOM---- 30 AMP AC OK--- | BRIAN | BRIAN | | E= | R | 4618598 |
SERVICE FIRST ELECTRIC | ES | C | 08/12/2013 | Residential Underground: NEW 150 AMP SERVICE | MIKEC | MIKEC | | ES | C | 4583342 |
SERVICE FIRST ELECTRIC | ER | C | 08/12/2013 | UNFINISHED BASEMENT. PLEASE CALL IN AS ERS NOT TWO INSPECTIONS | MIKEC | MIKEC | | ER | C | 4583210 |
GENE'S HEATING AND AIR LLC | H= | C | 10/08/2013 | ALL OK. NOTES: FP NO MANTEL - FULL AC - UNFINISHED BASEMENT - EQUIPMENT OK | JERRYF | JERRYF | | H= | C | 4618761 |
GENE'S HEATING AND AIR LLC | HC | C | 08/14/2013 | RELEASE METER | JERRYF | JERRYF | | HC | C | 4584951 |
GENE'S HEATING AND AIR LLC | HRR | C | 08/14/2013 | CORRECTIONS MADE - BY FINAL REVISE EQUIPMENT SHEETS TO MATCH WHAT IS INSTALLED | JERRYF | JERRYF | | HRR | C | 4584942 |
GENE'S HEATING AND AIR LLC | HRR | P | 08/12/2013 | MISSING SUPPLY IN LIVING ROOM AND DINING PER DUCT DESIGN - DESIGN SHOWS 4 TON FURNACE, 31/2 TON COIL HAS 5 TON FURNACE AND 4 TON COIL - REST OK NOTES: UNFINISHED BASEMENT - FIREPLACE FRAMING OK | JERRYF | JERRYF | | HRR | P | 4583159 |
KAMPP-L ENTERPRISES, INC. | HI | C | 08/09/2013 | 10# OK. NOTES: 1" MAIN - 50' DESIGN - FURN - WH - RNG- FP | JERRYF | JERRYF | | HI | C | 4582340 |
KAMPP-L ENTERPRISES, INC. | P= | C | 10/14/2013 | U/F BASEMENT | LEE | LEE | | P= | C | 4622373 |
KAMPP-L ENTERPRISES, INC. | PTO | C | 08/08/2013 | | LEE | LEE | | PTO | C | 4581612 |
KAMPP-L ENTERPRISES, INC. | PB | C | 06/19/2013 | no permit card found on site. | DICK | DICK | | PB | C | 4545860 |