STAUFFER AND SONS CONSTRUCTION | B= | C | 10/31/2013 | finished basement | JOND | JOND | | B= | C | 4633230 |
STAUFFER AND SONS CONSTRUCTION | BLA | C | 08/29/2013 | | JOND | JOND | | BLA | C | 4595147 |
STAUFFER AND SONS CONSTRUCTION | BIN | C | 08/21/2013 | | DANF | DANF | | BIN | C | 4590115 |
STAUFFER AND SONS CONSTRUCTION | BFR | C | 08/19/2013 | | JOND | JOND | | BFR | C | 4587871 |
STAUFFER AND SONS CONSTRUCTION | BFR | R | 08/08/2013 | No windows or doors installed, DO NOT INSULATE / Add A35 @ corner in kitchen / Fire block garage door brackets / Add bracing to gables, where over 6' bracing should be every 48" / Missing lateral bracing on A1E, B and B1 trusses / Can't see ST22 straps from kings to rim at any location / Missing LSTA straps at each side of garage portal / Anchor bolts to be within 12" of plate breaks / Add 2nd H2.5 @ B and B1 trusses along garage-porch wall / Add 2nd H2.5 at CJ mono truss over window / Fasten heels of J1A and CJ mono trusses for stability / Shim LVL beam pockets and glue all shims / Floating wall spike to be 12" from plate breaks and 32" O.C. | JEREMYA | JEREMYA | | BFR | R | 4581232 |
STAUFFER AND SONS CONSTRUCTION | BSP | P | 07/17/2013 | front porch and piers ok / letter on file | JOND | JOND | | BSP | P | 4565345 |
STAUFFER AND SONS CONSTRUCTION | BSP | R | 07/16/2013 | porch piers already poured | JOND | JOND | | BSP | R | 4564589 |
STAUFFER AND SONS CONSTRUCTION | BFD | C | 06/21/2013 | design, soils and open hole on file / drain usable area | JOND | JOND | | BFD | C | 4547831 |
STAUFFER AND SONS CONSTRUCTION | BFT | C | 06/17/2013 | | JOND | JOND | | BFT | C | 4544255 |
STAUFFER AND SONS CONSTRUCTION | BFN | C | 06/17/2013 | need new design and stamped open hole at drain / soils on file / ufer rod in | JOND | JOND | | BFN | C | 4544252 |
STAUFFER AND SONS CONSTRUCTION | BFT | P | 06/13/2013 | forms ok, need open hole letter (pour at own risk) | JOND | JOND | | BFT | P | 4542671 |
SPECTRUM, INC. | E= | C | 10/30/2013 | 30 AMP A.C | MIKEC | MIKEC | | E= | C | 4632544 |
SPECTRUM, INC. | ES | C | 08/06/2013 | Residential Underground: NEW 200 AMP SERVICE | MIKEC | MIKEC | | ES | C | 4579578 |
SPECTRUM, INC. | ER | C | 08/06/2013 | | MIKEC | MIKEC | | ER | C | 4579577 |
SPECTRUM, INC. | ES | R | 07/30/2013 | TOP CLOSURE MISSING IN METER | MIKEC | MIKEC | | ES | R | 4574095 |
SPECTRUM, INC. | ER | R | 07/30/2013 | CORRECTIONS NOT MADE. BOX NOT MADE UP IN MECH ROOM. ALSO CALL INSPECTION AS ERS NOT TWO INSPECTIONS. THANKS | MIKEC | MIKEC | | ER | R | 4574079 |
SPECTRUM, INC. | ER | R | 07/29/2013 | seal holes where nm runs thru air return , install flex or pan mn in air return from metal box basement bath hall, passing straight thru ok but from box out must be in metal raceway or panned | BRET | BRET | | ER | R | 4573686 |
SPECTRUM, INC. | ES | R | 07/29/2013 | seal nipple, install hub top of meter enclosure. | BRET | BRET | | ES | R | 4573685 |
BRUNO'S HEATING & COOLING | H= | C | 10/24/2013 | OK NOTES: A/C INSTALLED | KEITHW | KEITHW | | H= | C | 4628986 |
BRUNO'S HEATING & COOLING | HC | C | 07/31/2013 | RELEASE METER | JERRYF | JERRYF | | HC | C | 4575544 |
BRUNO'S HEATING & COOLING | HRR | C | 07/31/2013 | All OK. Notes: duct and furnace OK - finished basement - high / low grilles to mech with open stairwell - no osa design drawn or installed | JERRYF | JERRYF | | HRR | C | 4575543 |
DOUBLE J GAS, INC. | HI | C | 07/25/2013 | 10# OK. Notes: furnace not installed at this time - wh - rng - dry - fp - 11/4" main 90' design good for 424000 btu | JERRYF | JERRYF | | HI | C | 4571598 |
UNIQUE RADIANT HTG. & PLBG. | P= | C | 10/17/2013 | NOTE, HOT/COLD CROSSED AT KITCHEN SINK. NO SPRINKLER STUB. | DICK | DICK | | P= | C | 4624252 |
UNIQUE RADIANT HTG. & PLBG. | PTO | C | 07/29/2013 | CHECK EJECTOR PIPING ON FINAL | LEE | LEE | | PTO | C | 4573818 |
UNIQUE RADIANT HTG. & PLBG. | PB | C | 07/02/2013 | | LEE | LEE | | PB | C | 4556205 |