STAUFFER AND SONS CONSTRUCTION | B= | C | 11/14/2013 | finished basement | JOND | JOND | | B= | C | 4641645 |
STAUFFER AND SONS CONSTRUCTION | BLA | C | 09/13/2013 | | JOND | JOND | | BLA | C | 4604131 |
STAUFFER AND SONS CONSTRUCTION | BIN | C | 09/11/2013 | | JOND | JOND | | BIN | C | 4602445 |
STAUFFER AND SONS CONSTRUCTION | BIN | R | 09/09/2013 | need air barrier behind tubs and fireplace | JOND | JOND | | BIN | R | 4600544 |
STAUFFER AND SONS CONSTRUCTION | BFR | C | 09/05/2013 | | JOND | JOND | | BFR | C | 4598856 |
STAUFFER AND SONS CONSTRUCTION | BFR | R | 09/04/2013 | laterals missing throughout trusses / pt load down HG01 / cleanout b-vent chase / fireblock garage brackets / nail off dbl ml hanger by front hallway / ok to insulate | JOND | JOND | | BFR | R | 4598040 |
STAUFFER AND SONS CONSTRUCTION | BSP | P | 08/15/2013 | Rear deck piers OK | JEREMYA | JEREMYA | | BSP | P | 4586130 |
STAUFFER AND SONS CONSTRUCTION | BFN | C | 07/11/2013 | received soils letter, open hole letter, fdtn design and copy of eng inspection report/ float any walls on slab a minimum of 1.5 inches/ 5% final grade req'd | BLAKE | BLAKE | | BFN | C | 4561614 |
STAUFFER AND SONS CONSTRUCTION | BFT | C | 07/11/2013 | received copy of eng inspection report | BLAKE | BLAKE | | BFT | C | 4561613 |
STAUFFER AND SONS CONSTRUCTION | BFD | C | 07/11/2013 | | BLAKE | BLAKE | | BFD | C | 4561612 |
STAUFFER AND SONS CONSTRUCTION | BFT | P | 07/01/2013 | footing forms ok / need open hole letter (pour at own risk) | JOND | JOND | | BFT | P | 4554594 |
SPECTRUM, INC. | E= | C | 11/13/2013 | | MIKEC | MIKEC | | E= | C | 4640772 |
SPECTRUM, INC. | E= | R | 11/12/2013 | CHECK BATH GFI CIRCUIT OUTLET SWITCHED WITH LIGHT.----------------A.C PREWIRE | MIKEC | MIKEC | | E= | R | 4639617 |
SPECTRUM, INC. | ER | C | 08/29/2013 | | MIKEC | MIKEC | | ER | C | 4595684 |
SPECTRUM, INC. | ES | C | 08/29/2013 | Residential Underground: NEW 200 AMP SERVICE | MIKEC | MIKEC | | ES | C | 4595676 |
SPECTRUM, INC. | ER | R | 08/28/2013 | NOT READY | MIKEC | MIKEC | | ER | R | 4594524 |
SPECTRUM, INC. | ES | R | 08/28/2013 | NOT READY | MIKEC | MIKEC | | ES | R | 4594500 |
BRUNO'S HEATING & COOLING | H= | C | 11/05/2013 | OK NOTES: ROUGH A/C WITH COIL AND LINE SET, FINISHED BASEMENT | KEITHW | KEITHW | | H= | C | 4635986 |
BRUNO'S HEATING & COOLING | HC | C | 09/03/2013 | RELEASE METER | JERRYF | JERRYF | | HC | C | 4597222 |
BRUNO'S HEATING & COOLING | HRR | C | 09/03/2013 | CORRECTIONS MADE NOTES: READ ALL PREVIOUS NOTES AT FINAL | JERRYF | JERRYF | | HRR | C | 4597204 |
BRUNO'S HEATING & COOLING | HRR | P | 08/29/2013 | DUCT DESIGN SHOWS 12" RD. FOR RETURN HAS 10" INSTALLED - WHERE WILL 2ND FLOOR SUPPLY NEEDS TO BE INSULATED ABOVE SOFFIT - WILL NEED NEED DUCT LEAK TEST BY FINAL - REST OK. NOTES: FURNACE OK - COIL AND LINESET - FINISHED BASEMENT - NO OSA DESIGNED OR INSTALLED - FP FRAMING OK | JERRYF | JERRYF | | HRR | P | 4595531 |
DOUBLE J GAS, INC. | HI | C | 08/26/2013 | 10# OK. NOTES: 11/4" MAIN - 80' DESIGN - FURN-WH- 2 FP - CKT - DRY - TOTAL CONNECTED LOAD 237000 BTU | JERRYF | JERRYF | | HI | C | 4592549 |
DOUBLE J GAS, INC. | HI | R | 08/23/2013 | LOST TEST - STOPPED INSPECTION | JERRYF | JERRYF | | HI | R | 4591715 |
UNIQUE RADIANT HTG. & PLBG. | P= | C | 11/13/2013 | | TIM | TIM | | P= | C | 4640355 |
UNIQUE RADIANT HTG. & PLBG. | PTO | C | 08/28/2013 | correction made. | DICK | DICK | | PTO | C | 4594314 |
UNIQUE RADIANT HTG. & PLBG. | PTO | P | 08/27/2013 | SIX D.F.U.ON 2" WET VENT AT MASTER BATH, MAX. 4 ALLOWED BY CODE -- REST OK | LEE | LEE | | PTO | P | 4593829 |
UNIQUE RADIANT HTG. & PLBG. | PB | C | 07/18/2013 | | LEE | LEE | | PB | C | 4566917 |