CANAAN COMPANY, LLC | B= | C | 12/24/2013 | | BERTW | BERTW | | B= | C | 4662373 |
CANAAN COMPANY, LLC | B= | P | 12/04/2013 | Temp CO: pending building final ( Expires: 1/3/2014 12:00:00 AM) | BPHILLIPS | BPHILLIPS | | B= | P | 4652001 |
CANAAN COMPANY, LLC | B= | P | 11/26/2013 | Additional Inspections Required: External Agency Inspection N= by ENGINEERING is not Completed yet (Contact: enijkamp@springsgov.com or 385-5977). need egress windows going out front bedroom / egress ladder at south bedroom in basement / need tempered window by deck stair landing / finished basement -- Schedule a new Building Final when above items are complete. | JOND | JOND | | B= | P | 4648355 |
CANAAN COMPANY, LLC | BSP | P | 10/29/2013 | landing piers ok at rear deck | JOND | JOND | | BSP | P | 4631377 |
CANAAN COMPANY, LLC | BLA | C | 09/16/2013 | | JOND | JOND | | BLA | C | 4604899 |
CANAAN COMPANY, LLC | BFR | C | 09/11/2013 | engineer letters on file / new truss calcs on file | JOND | JOND | | BFR | C | 4602640 |
CANAAN COMPANY, LLC | BIN | C | 09/11/2013 | | JOND | JOND | | BIN | C | 4602638 |
CANAAN COMPANY, LLC | BFR | R | 09/10/2013 | cancelled in field | JOND | JOND | | BFR | R | 4601553 |
CANAAN COMPANY, LLC | BFR | R | 09/09/2013 | trusses are not matching / nail off strap at girder in garage / glue shims at ml beam pocket and grout to cover exposed rebar / need engineer letter for broken trusses / need letter for change of size of glue lam at deck beam / ok to insulate | JOND | JOND | | BFR | R | 4600896 |
CANAAN COMPANY, LLC | BSP | P | 08/15/2013 | Front and rear porch lids OK | JEREMYA | JEREMYA | | BSP | P | 4586287 |
CANAAN COMPANY, LLC | BSP | P | 07/22/2013 | 24" pier in back ok | JOND | JOND | | BSP | P | 4568466 |
CANAAN COMPANY, LLC | BFD | C | 07/15/2013 | | BLAKE | BLAKE | | BFD | C | 4563445 |
CANAAN COMPANY, LLC | BFI | C | 07/15/2013 | | BLAKE | BLAKE | | BFI | C | 4563413 |
CANAAN COMPANY, LLC | BFT | C | 07/15/2013 | rec'd copy of eng inspection report | BLAKE | BLAKE | | BFT | C | 4563412 |
CANAAN COMPANY, LLC | BFN | C | 07/15/2013 | received open hole, soils letter, compaction test, fdtn design and eng inspection report/ float all walls on slab a minimum of 1.5 inches/ 10 % final grade req'd | BLAKE | BLAKE | | BFN | C | 4563411 |
CANAAN COMPANY, LLC | BFN | P | 06/28/2013 | AUTHORIZED INSPECTION BY ENGINEER | RITA | RITA | RITA | BFN | P | 4553161 |
CANAAN COMPANY, LLC | BFT | P | 06/28/2013 | AUTHORIZED INSPECTION BY ENGINEER | RITA | RITA | RITA | BFT | P | 4553160 |
POSITIVE ELECTRIC, LLC | E= | C | 11/22/2013 | | MIKEC | MIKEC | | E= | C | 4647208 |
POSITIVE ELECTRIC, LLC | E= | R | 11/21/2013 | WASHER OUTLET IN MECH ROOM NOT GFCI | MIKEC | MIKEC | | E= | R | 4646553 |
POSITIVE ELECTRIC, LLC | ES | C | 09/06/2013 | Residential Underground: 200 amp 3-w new res .. --- ok to set meter | BRIAN | BRIAN | | ES | C | 4599915 |
POSITIVE ELECTRIC, LLC | ER | C | 09/06/2013 | need cold water jumper -- check on final-----notes --- 2-- 20 2--- 6-3 al 1 8-2 copper | BRIAN | BRIAN | | ER | C | 4599911 |
POSITIVE ELECTRIC, LLC | ER | R | 09/05/2013 | NOT READY | MIKEC | MIKEC | | ER | R | 4598959 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | C | 11/21/2013 | OK NOTES: LOUVER DOOR, A/C INSTALLED | KEITHW | KEITHW | | H= | C | 4646151 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HC | C | 09/06/2013 | RELEASE METER | JERRYF | JERRYF | | HC | C | 4600004 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | C | 09/06/2013 | ALL OK. NOTES: DUCT AND FURNACE GOOD - FINISHED BASEMENT - COIL AND LINESET COMPLETE WH FLUE BY FINAL - INSTALL ALL CAPS AND COLLARS BY FINAL - NO OSA DESIGNED OR INSTALLED - 2 FP FRAMING OK | JERRYF | JERRYF | | HRR | C | 4599996 |
UNIQUE RADIANT HTG. & PLBG. | HI | C | 09/06/2013 | 10# OK. NOTES: 11/4" MAIN SEE PREVIOUS NOTES | JERRYF | JERRYF | | HI | C | 4599990 |
UNIQUE RADIANT HTG. & PLBG. | HI | R | 09/04/2013 | NEED 10# ON 30# GAUGE - 1" AT 90' CARRIES 207000 BTU - HAVE 238000 BTU INSTALLED NOTES: FURN - WH - 2 FP - BBQ | JERRYF | JERRYF | | HI | R | 4598165 |
UNIQUE RADIANT HTG. & PLBG. | P= | C | 11/12/2013 | | TIM | TIM | | P= | C | 4639111 |
UNIQUE RADIANT HTG. & PLBG. | P= | P | 11/08/2013 | SCALDING WATER MASTER SHOWER -- NO WAY TO GET PUMP OUT WITH ACCESS THRU CABINET (PULL OUT TO VERIFY ACCESS) -- KITCHEN HIGH LOOP 4" TOO LOW -- LEAKS UNDER LAVS BOTH BASEMENT BATHROOMS | LEE | LEE | | P= | P | 4638736 |
UNIQUE RADIANT HTG. & PLBG. | PTO | C | 09/03/2013 | FINISHED BASEMENT | JOEL | JOEL | | PTO | C | 4597253 |
UNIQUE RADIANT HTG. & PLBG. | PB | C | 07/19/2013 | | LEE | LEE | | PB | C | 4567834 |