SOLID ROCK CONSTRUCTION, LLC | B= | C | 04/23/2014 | All other required Final inspections are complete. (This is a computer generated result) | JOND | JOND | | B= | C | 4725750 |
SOLID ROCK CONSTRUCTION, LLC | B= | P | 04/22/2014 | Additional Inspections Required: External Agency Inspection F= by FIREDEPT is not Completed yet (Contact: 385-5982, x2), External Agency Inspection N= by ENGINEERING is not Completed yet (Contact: enijkamp@springsgov.com or 385-5977). finished basement | JOND | JOND | | B= | P | 4724483 |
SOLID ROCK CONSTRUCTION, LLC | BLA | C | 02/10/2014 | | JOND | JOND | | BLA | C | 4684937 |
SOLID ROCK CONSTRUCTION, LLC | BFR | C | 10/23/2013 | | JOND | JOND | | BFR | C | 4627910 |
SOLID ROCK CONSTRUCTION, LLC | BIN | C | 10/23/2013 | | JOND | JOND | | BIN | C | 4627901 |
SOLID ROCK CONSTRUCTION, LLC | BFR | R | 10/21/2013 | middle bearing clips at trusses by garage / brace off north gable / hts20 straps at A7 - A4 / need t-post connected to beam / hangers missing at dropped floor / ok to insulate | JOND | JOND | | BFR | R | 4626352 |
SOLID ROCK CONSTRUCTION, LLC | BSP | P | 10/03/2013 | deck piers ok | JOND | JOND | | BSP | P | 4615872 |
SOLID ROCK CONSTRUCTION, LLC | BFD | C | 07/16/2013 | | JOND | JOND | | BFD | C | 4564596 |
SOLID ROCK CONSTRUCTION, LLC | BFI | C | 07/16/2013 | | JOND | JOND | | BFI | C | 4564595 |
SOLID ROCK CONSTRUCTION, LLC | BFT | C | 07/16/2013 | engineer letter on file | JOND | JOND | | BFT | C | 4564594 |
SOLID ROCK CONSTRUCTION, LLC | BFN | C | 07/16/2013 | engineer letter on file / design, open hole on file / drain usable area | JOND | JOND | | BFN | C | 4564593 |
SOLID ROCK CONSTRUCTION, LLC | BFN | P | 07/16/2013 | AUTHORIZED INSPECTION BY ENGINEER | TERRI | TERRI | TERRI | BFN | P | 4563613 |
SOLID ROCK CONSTRUCTION, LLC | BFT | P | 07/16/2013 | AUTHORIZED INSPECTION BY ENGINEER | TERRI | TERRI | TERRI | BFT | P | 4563612 |
D & J QUALITY ELECTRIC INC | E= | C | 03/28/2014 | | MIKEC | MIKEC | | E= | C | 4710917 |
D & J QUALITY ELECTRIC INC | ER | C | 10/10/2013 | | BRIAN | BRIAN | | ER | C | 4620243 |
D & J QUALITY ELECTRIC INC | ES | C | 10/09/2013 | Residential Underground: 200 AMP 3-W NEW RES OK | BRIAN | BRIAN | | ES | C | 4619627 |
D & J QUALITY ELECTRIC INC | ER | R | 10/09/2013 | NEED ISLAND ROUGH IN | BRIAN | BRIAN | | ER | R | 4619625 |
BRUNO'S HEATING & COOLING | H= | C | 04/10/2014 | High/low transfer in wall, full a/c, mantel ok, FB. | MICHAELS | MICHAELS | | H= | C | 4718313 |
UNIQUE RADIANT HTG. & PLBG. | HC | C | 10/04/2013 | RELEASE METER | JERRYF | JERRYF | | HC | C | 4617173 |
UNIQUE RADIANT HTG. & PLBG. | HI | C | 10/04/2013 | 10# OK. | JERRYF | JERRYF | | HI | C | 4617170 |
UNIQUE RADIANT HTG. & PLBG. | HI | P | 10/03/2013 | NEED 10# ON 30# GAUGE - REST OK. NOTES: 11/4" MAIN - 100' DESIGN - FURN - WH - CKT - BBQ - COOKTOP STUB NOT INSTALLED YET WILL NEED AIR TEST BEFORE FINAL | JERRYF | JERRYF | | HI | P | 4616010 |
BRUNO'S HEATING & COOLING | HRR | C | 09/30/2013 | CORRECTION MADE | JERRYF | JERRYF | | HRR | C | 4613469 |
BRUNO'S HEATING & COOLING | HRR | P | 09/27/2013 | Pan R/A in bsmt. bdrm. above soffit, rest ok. Note: duct design, FB, no osa, a/c rough(coil and lineset), direct vent furnace, indirect w/h. | MICHAELS | MICHAELS | | HRR | P | 4612211 |
BRUNO'S HEATING & COOLING | HRR | P | 09/26/2013 | NEED APPROVED PLANS STOPPED INSPECTION | JERRYF | JERRYF | | HRR | P | 4611695 |
UNIQUE RADIANT HTG. & PLBG. | P= | C | 04/11/2014 | correction made | DICK | DICK | | P= | C | 4718766 |
UNIQUE RADIANT HTG. & PLBG. | P= | P | 04/10/2014 | no hot water, master bath not complete. | DICK | DICK | | P= | P | 4717811 |
UNIQUE RADIANT HTG. & PLBG. | PTO | C | 09/20/2013 | RP BACK-FLOW IN BASEMENT. FINISHED BASEMENT. | DICK | DICK | | PTO | C | 4607733 |
UNIQUE RADIANT HTG. & PLBG. | PB | C | 07/25/2013 | | LEE | LEE | | PB | C | 4571849 |