PETRA HOMES, INC. | B= | C | 08/15/2014 | finished basement | JOND | JOND | | B= | C | 4797795 | PETRA HOMES, INC. | BSP | R | 04/23/2014 | cancelled in field | JOND | JOND | | BSP | R | 4725950 | PETRA HOMES, INC. | BLA | C | 03/10/2014 | | JOND | JOND | | BLA | C | 4699723 | PETRA HOMES, INC. | BIN | C | 01/31/2014 | | JOND | JOND | | BIN | C | 4681566 | PETRA HOMES, INC. | BFR | C | 01/24/2014 | check firestop at insulation | JOND | JOND | | BFR | C | 4677309 | PETRA HOMES, INC. | BFR | R | 01/21/2014 | brace off laterals at back of house / roll block trusses at back wall / firestop throughout / BG2 straps and bearing ? / roof vents not cut in / deck frame not ready / ok to insulate / engineer letters on file | JOND | JOND | | BFR | R | 4675012 | PETRA HOMES, INC. | BSP | P | 11/19/2013 | back porch ok, deck frame not ready | JOND | JOND | | BSP | P | 4644577 | PETRA HOMES, INC. | BSP | P | 11/12/2013 | front porch ok | JOND | JOND | | BSP | P | 4639689 | PETRA HOMES, INC. | BFD | P | 08/09/2013 | need to know what the requirements are from the open hole ; usable is installed now | DANF | DANF | | BFD | P | 4582459 | PETRA HOMES, INC. | BFI | C | 08/09/2013 | | DANF | DANF | | BFI | C | 4582458 | PETRA HOMES, INC. | BFN | P | 08/09/2013 | foundation design and soils letter on file; need stamped open hole observation; need to know drain requirments; 5% slope from foundation, ISO, flaot ; Ufer OK | DANF | DANF | | BFN | P | 4582455 | PETRA HOMES, INC. | BFT | C | 08/09/2013 | Mibar engineering on file for footer, foundation steel, and Ufer observation | DANF | DANF | | BFT | C | 4582450 | PETRA HOMES, INC. | BFT | P | 07/17/2013 | AUTHORIZED INSPECTION BY ENGINEER | JANE | JANE | JANE | BFT | P | 4565088 | PETRA HOMES, INC. | BFN | P | 07/17/2013 | AUTHORIZED INSPECTION BY ENGINEER | JANE | JANE | JANE | BFN | P | 4565089 | HOMERUN ELECTRONICS, INC. | E= | C | 07/18/2014 | | MIKEC | MIKEC | | E= | C | 4779757 | HOMERUN ELECTRONICS, INC. | E= | R | 07/09/2014 | NEED ARC SHIELD ON SWITCHBOX BY MAIN LEVEL BEDROOM,NO POWER TO OUTLETS LL BEDROOM | MIKEC | MIKEC | | E= | R | 4773929 | HOMERUN ELECTRONICS, INC. | ES | C | 12/30/2013 | Residential Underground: 200 amp 3/w new res OK to energize | CRAIGS | CRAIGS | | ES | C | 4664132 | HOMERUN ELECTRONICS, INC. | ES | R | 12/26/2013 | BOND SCREW STRIPPED | MIKEC | MIKEC | | ES | R | 4662903 | HOMERUN ELECTRONICS, INC. | ER | C | 12/26/2013 | | MIKEC | MIKEC | | ER | C | 4662901 | HOMERUN ELECTRONICS, INC. | ES | R | 12/24/2013 | See rough | SHELBY | SHELBY | | ES | R | 4662509 | HOMERUN ELECTRONICS, INC. | ER | R | 12/24/2013 | Basement temp power requires GFCI protection----Repair SER sheathing two feet from basement in garage wall-----for service 7 215 and 3 220---basement sub panel OK no mutiwire---automation panel and puck light control on wall strait across from sub panel need to be checked on final---finished basement | SHELBY | SHELBY | | ER | R | 4662507 | A & Z MECHANICAL, INC. | H= | C | 06/17/2014 | OK NOTES: A/C INSTALLED ON MAIN UNIT, UNFINISHED MECHANICAL ROOM | KEITHW | KEITHW | | H= | C | 4759761 | A & Z MECHANICAL, INC. | HC | C | 12/30/2013 | RELEASE METER. | NANCY | NANCY | | HC | C | 4664407 | A & Z MECHANICAL, INC. | HRR | C | 12/30/2013 | GAS LINE TO MAIN LAUNDRY ROOM HAS BEEN CAPPED AND COVERED IN WALL. ELECTRIC DRYER TO BE INSTALLED PER DRYER BOOSTER FAN INSTRUCTIONS. NOTE: FINISHED BASEMENT. A/C ROUGH, COIL AND LINESET ON MAIN FURNACE ONLY. | NANCY | NANCY | | HRR | C | 4664404 | A & Z MECHANICAL, INC. | HRR | P | 12/23/2013 | FINISH FRAMING ON MASTER FIREPLACE. BOOSTER FANS FOR DRYERS NOT ALLOWED AND GAS DRYERS. DOES NOT APPEAR TO HAVE USED FACTORY DUCTS ALSO. NEED INSTRUCTIONS FOR DRYER BOOSTER FANS IF GAS LINES ARE REMOVED. ALSO DRYER DUCT IN BASEMENT HAS IMPROPER JOINT THAT IS NOT FULL 1 1/2" JOINT AND IS NOT SEALED UP INSIDE FLOOR JOIST, NEED TO SEE ACCESS OPENING AS WELL. REST OK | JON | JON | | HRR | P | 4662017 | L & L GAS SHOP, LLC. | HI | C | 11/27/2013 | 10 PSI TEST OK NOTES: 1 1/2" GAS LINE, 2-DRYER, 3-FIREPLACE, RANGE, BBQ, UNIT HEATER GARAGE, 2-FURNACE, 2-WATER HEATER | KEITHW | KEITHW | | HI | C | 4649154 | TEAM PLUMBING, INC. | P= | C | 06/05/2014 | | TIM | TIM | | P= | C | 4751793 | TEAM PLUMBING, INC. | P= | P | 05/23/2014 | no hot water. rest ok, finished basement, rp back flow installed. | DICK | DICK | | P= | P | 4744769 | TEAM PLUMBING, INC. | PTO | C | 11/15/2013 | | TIM | TIM | | PTO | C | 4642299 | TEAM PLUMBING, INC. | PB | C | 08/19/2013 | | LEE | LEE | | PB | C | 4588230 | TEAM PLUMBING, INC. | PB | P | 08/16/2013 | 3/4" COPPER THRU WALL LACKS PLASTIC SLEEVE -- REST OK | LEE | LEE | | PB | P | 4587320 |
|
|