SOLOMONS CONSTRUCTION, LLC | B= | C | 12/20/2013 | | JOND | JOND | | B= | C | 4661259 |
SOLOMONS CONSTRUCTION, LLC | B= | P | 12/18/2013 | Temp CO: building final items and electrical final ( Expires: 1/17/2014 12:00:00 AM) | MINDY | MINDY | | B= | P | 4659418 |
SOLOMONS CONSTRUCTION, LLC | B= | P | 12/13/2013 | Additional Inspections Required: External Agency Inspection N= by ENGINEERING is not Completed yet (Contact: enijkamp@springsgov.com or 385-5977), Electrical Final Inspection is not Completed yet. need 5" house numbers / need electrical final signed off / doors blocked out to balcony (missing guardrail) / need egress ladder in basement / touch up final grade / pipe all downspouts away from house / touch up final grade / finish outside columns / unfinished basement -- Schedule a new Building Final when above items are complete. | JOND | JOND | | B= | P | 4656793 |
SOLOMONS CONSTRUCTION, LLC | BIN | C | 10/17/2013 | | JOND | JOND | | BIN | C | 4624365 |
SOLOMONS CONSTRUCTION, LLC | BFR | C | 10/17/2013 | | JOND | JOND | | BFR | C | 4624349 |
SOLOMONS CONSTRUCTION, LLC | BFR | R | 10/16/2013 | cancelled in field | JOND | JOND | | BFR | R | 4623509 |
SOLOMONS CONSTRUCTION, LLC | BLA | C | 10/16/2013 | | JOND | JOND | | BLA | C | 4623508 |
SOLOMONS CONSTRUCTION, LLC | BFR | R | 10/14/2013 | need truss calcs, no truss inspection / 16" oc framing at dropped soffit in garage / fireblock b-vent chase in garage / bring down pt loads in basment / basement is framed but not finishing / ok to insulate | JOND | JOND | | BFR | R | 4622381 |
SOLOMONS CONSTRUCTION, LLC | BFR | R | 10/11/2013 | 1- no approved plans and truss details on site, called contractor at 337-8124 no answer 2- fireblocking missing 3- recall inspection | BLAKE | BLAKE | | BFR | R | 4621175 |
SOLOMONS CONSTRUCTION, LLC | BSP | P | 09/17/2013 | front porch ok | JOND | JOND | | BSP | P | 4605538 |
SOLOMONS CONSTRUCTION, LLC | BFD | C | 08/09/2013 | drain usable | DANF | DANF | | BFD | C | 4582329 |
SOLOMONS CONSTRUCTION, LLC | BFN | P | 08/09/2013 | foundation design and soil letter on file; need stamped copy of open hole observation; ISO, float, drain usable, 5% slope from foundation; Ufer OK | DANF | DANF | | BFN | P | 4582325 |
SOLOMONS CONSTRUCTION, LLC | BFT | C | 08/09/2013 | Mibar engineering letter of observation on file for footer, foundation steel and Ufer | DANF | DANF | | BFT | C | 4582322 |
SOLOMONS CONSTRUCTION, LLC | BFT | P | 07/24/2013 | AUTHORIZED INSPECTION BY ENGINEER | NELIDA | NELIDA | NELIDA | BFT | P | 4570830 |
SOLOMONS CONSTRUCTION, LLC | BFN | P | 07/24/2013 | AUTHORIZED INSPECTION BY ENGINEER | NELIDA | NELIDA | NELIDA | BFN | P | 4570831 |
CL SHARPER ELECTRIC | E= | C | 12/19/2013 | | MIKEC | MIKEC | | E= | C | 4660561 |
HOMEOWNER | E= | P | 12/13/2013 | SWITCHES NOT GROUNDED | MIKEC | MIKEC | | E= | P | 4656831 |
CL SHARPER ELECTRIC | E= | P | 12/13/2013 | SWITCHES NOT GROUNDED | MIKEC | MIKEC | | E= | P | 4656790 |
CL SHARPER ELECTRIC | E= | R | 12/12/2013 | GROUND ALL SWITCHES,HOMELINE HANDLE TIE,TROUBLE SHOOT ARC FAULT CIRCUIT CHANGE CLOSET FIXTURE (BUILDER SAID HE WOULD SUPPLY ) | MIKEC | MIKEC | | E= | R | 4656008 |
ABETA ENTERPRISES & ELECTRIC, LLC | E= | R | 12/11/2013 | NOT READY CHANGE FAULT CURRENT RETING | MIKEC | MIKEC | | E= | R | 4655160 |
ABETA ENTERPRISES & ELECTRIC, LLC | ES | C | 10/21/2013 | Residential Underground: NEW 200 AMP SERVICE | MIKEC | MIKEC | | ES | C | 4626060 |
ABETA ENTERPRISES & ELECTRIC, LLC | ES | T | 10/17/2013 | PAID (REC#1161272) STILL NOT READY | MIKEC | MIKEC | | ES | T | 4624812 |
ABETA ENTERPRISES & ELECTRIC, LLC | ES | T | 10/15/2013 | PAID (REC#1160621) NOT READY | MIKEC | MIKEC | | ES | T | 4623032 |
ABETA ENTERPRISES & ELECTRIC, LLC | ER | C | 10/10/2013 | NOTES ----- BASEMENT FRAMED BUT NOT GOING TO FINISH AT THIS TIME | BRIAN | BRIAN | | ER | C | 4620383 |
ABETA ENTERPRISES & ELECTRIC, LLC | ES | R | 10/10/2013 | NOT READY | BRIAN | BRIAN | | ES | R | 4620382 |
ABETA ENTERPRISES & ELECTRIC, LLC | ES | R | 10/08/2013 | not ready | BRIAN | BRIAN | | ES | R | 4618722 |
ABETA ENTERPRISES & ELECTRIC, LLC | ER | R | 10/08/2013 | not ready | BRIAN | BRIAN | | ER | R | 4618721 |
ABETA ENTERPRISES & ELECTRIC, LLC | ER | R | 10/07/2013 | far from ready!!!!!!!!!!!!! | CRAIGS | CRAIGS | | ER | R | 4617805 |
ABETA ENTERPRISES & ELECTRIC, LLC | ES | R | 10/07/2013 | far from ready !!!!!!!!!!!!! | CRAIGS | CRAIGS | | ES | R | 4617791 |
ABETA ENTERPRISES & ELECTRIC, LLC | ER | R | 10/03/2013 | NOT READY | MIKEC | MIKEC | | ER | R | 4616218 |
JOHNSON HEATING AND PLUMBING, INC. | H= | C | 12/09/2013 | OK NOTES: UNFINISHED BASEMENT, ROUGH A/C | KEITHW | KEITHW | | H= | C | 4653927 |
JOHNSON HEATING AND PLUMBING, INC. | HC | C | 10/04/2013 | RELEASE METER | JERRYF | JERRYF | | HC | C | 4617169 |
JOHNSON HEATING AND PLUMBING, INC. | HRR | C | 10/04/2013 | CORRECTION MADE | JERRYF | JERRYF | | HRR | C | 4617166 |
JOHNSON HEATING AND PLUMBING, INC. | HRR | P | 10/03/2013 | COMPLETE FIREPLACE FRAMING - REST OK | JERRYF | JERRYF | | HRR | P | 4615956 |
JOHNSON HEATING AND PLUMBING, INC. | HI | C | 09/25/2013 | 10# test ok. 1" main to furn, w/h, fp, range. | MICHAELS | MICHAELS | | HI | C | 4610302 |
JOHNSON HEATING AND PLUMBING, INC. | HRR | P | 09/25/2013 | Drop ceilings in bath rooms, frame b-vent in garage, install fp. Performance test by final. Note: FB, 6" osa, a/c rough(coil only), direct vent furnace. | MICHAELS | MICHAELS | | HRR | P | 4610294 |
JOHNSON HEATING AND PLUMBING, INC. | P= | C | 12/12/2013 | drain completed | JACK | JACK | | P= | C | 4656021 |
JOHNSON HEATING AND PLUMBING, INC. | P= | P | 12/12/2013 | additional trip required finish dishwasher drain as noted | TIM | TIM | | P= | P | 4655546 |
JOHNSON HEATING AND PLUMBING, INC. | P= | R | 12/10/2013 | cap open drains, finish dishwasher drain, master toilet lacks required side clearance | TIM | TIM | | P= | R | 4654271 |
JOHNSON HEATING AND PLUMBING, INC. | P= | P | 12/09/2013 | field cancel | TIM | TIM | | P= | P | 4653785 |
JOHNSON HEATING AND PLUMBING, INC. | PTO | C | 10/01/2013 | BY FINAL SUPPORT PEX TO CODE IN UNFINISHED BASEMENT -- FIX GRADE ON FUTURE LAV FIXTURE DRAIN -- ISOLATE PEX FROM EDGES OF DUCT | LEE | LEE | | PTO | C | 4614483 |
JOHNSON HEATING AND PLUMBING, INC. | PB | C | 08/16/2013 | LACKS 6" SLEEVE IN FOUNDATION WALL FOR BUILDING DRAIN -- WILL CHECK ON PTO | LEE | LEE | | PB | C | 4587322 |