CUSTOM DESIGN BUILDERS, INC | B= | C | 01/10/2014 | finished basement | CHRISM | CHRISM | | B= | C | 4669914 |
CUSTOM DESIGN BUILDERS, INC | B= | R | 01/09/2014 | Additional Inspections Required: Plumbing Final Inspection is not Completed yet. finished basement, address numbers on house, gutters and downspouts | CHRISM | CHRISM | | B= | R | 4669032 |
CUSTOM DESIGN BUILDERS, INC | BLA | C | 11/19/2013 | | CHRISM | CHRISM | | BLA | C | 4644514 |
CUSTOM DESIGN BUILDERS, INC | BIN | C | 11/15/2013 | | CHRISM | CHRISM | | BIN | C | 4642698 |
CUSTOM DESIGN BUILDERS, INC | BFR | C | 11/15/2013 | | CHRISM | CHRISM | | BFR | C | 4642693 |
CUSTOM DESIGN BUILDERS, INC | BIN | P | 11/01/2013 | insulation ok, clear bfr, shim beam pocket at stairs, backrock electric panel | CHRISM | CHRISM | | BIN | P | 4634272 |
CUSTOM DESIGN BUILDERS, INC | BFR | R | 10/30/2013 | ok to insulate after ER, shim beam in pockets, strap top plates of rake wall, rock behind electric panel in house to garage wall | CHRISM | CHRISM | | BFR | R | 4632291 |
CUSTOM DESIGN BUILDERS, INC | BSP | P | 10/10/2013 | front porch and posts ok | CHRISM | CHRISM | | BSP | P | 4620494 |
CUSTOM DESIGN BUILDERS, INC | BFD | C | 09/16/2013 | | CHRISM | CHRISM | | BFD | C | 4604886 |
CUSTOM DESIGN BUILDERS, INC | BFN | C | 09/16/2013 | | CHRISM | CHRISM | | BFN | C | 4604885 |
CUSTOM DESIGN BUILDERS, INC | BFT | C | 09/16/2013 | eng report on file | CHRISM | CHRISM | | BFT | C | 4604881 |
CUSTOM DESIGN BUILDERS, INC | BFD | P | 09/12/2013 | drain usable ok, need stamped open hole | CHRISM | CHRISM | | BFD | P | 4603876 |
CUSTOM DESIGN BUILDERS, INC | BFN | P | 09/12/2013 | design and eng report on file, clear bft | CHRISM | CHRISM | | BFN | P | 4603863 |
CUSTOM DESIGN BUILDERS, INC | BFT | R | 09/12/2013 | need eng inspection report for footer | CHRISM | CHRISM | | BFT | R | 4603861 |
CURTIS ELECTRICAL CONTRACTORS LLC | EUG | C | 01/06/2014 | | BRIAN | BRIAN | | EUG | C | 4667063 |
CURTIS ELECTRICAL CONTRACTORS LLC | ES | C | 01/06/2014 | Residential Underground: 200 AMP 3-W OK NEW RES------OK TO RE SEAL METER----- | BRIAN | BRIAN | | ES | C | 4667062 |
CURTIS ELECTRICAL CONTRACTORS LLC | E= | C | 01/06/2014 | CORRECTIONS MADE | BRIAN | BRIAN | | E= | C | 4667061 |
CURTIS ELECTRICAL CONTRACTORS LLC | E= | R | 01/03/2014 | afci stairs, gfci single outlets in garage and at sump, gfci wet bar micro, need disconnect for mr. steam, 20 amp max for a/c, re-label panel (use white out not white tape), gfci washer (not behind appliance), 40 amp max for oven--------------- underground not complete------------- need service inspection | MATTHEW | MATTHEW | | E= | R | 4666441 |
CURTIS ELECTRICAL CONTRACTORS LLC | EUG | P | 11/05/2013 | ditch ok but no wire installed | BRIAN | BRIAN | | EUG | P | 4635897 |
CURTIS ELECTRICAL CONTRACTORS LLC | ER | C | 10/30/2013 | panel location approved by chris morin---------check mcc's at time of service | MATTHEW | MATTHEW | | ER | C | 4632699 |
CURTIS ELECTRICAL CONTRACTORS LLC | ER | R | 10/28/2013 | need to land home runs into panel---need outlet for jet tub----strap # 10 nm in guest bath-- | BRIAN | BRIAN | | ER | R | 4630745 |
ADVANTAGE HEATING AND COOLING | H= | C | 01/07/2014 | high low t-grills a/c complete | TIM | TIM | | H= | C | 4667592 |
HODGES PLUMBING INC | HI | C | 10/25/2013 | 10 LB TEST OK NOTE 1 FURN,F/P | DAVIDH | DAVIDH | | HI | C | 4629533 |
ADVANTAGE HEATING AND COOLING | HRR | C | 10/18/2013 | OK NOTE 6" OSA FINISHED BASEMENT EQUIP CHECK OK | DAVIDH | DAVIDH | | HRR | C | 4625521 |
G & L PLUMBING | P= | C | 01/09/2014 | no irrigation | JOEL | JOEL | | P= | C | 4669049 |
G & L PLUMBING | P= | P | 01/08/2014 | need potable cert., complete irrigation bfp, seperate drains from steamer unit, leak under master lav | JOEL | JOEL | | P= | P | 4668520 |
HOMEOWNER | PWO | C | 11/01/2013 | | TIM | TIM | | PWO | C | 4634380 |
HOMEOWNER | PWO | P | 10/31/2013 | need tracer wire | TIM | TIM | | PWO | P | 4633137 |
G & L PLUMBING | PTO | C | 10/23/2013 | at final check clearance on steam line from flex duct in mech. room ceiling, note: finished basement, | TED | TED | | PTO | C | 4627781 |
G & L PLUMBING | PB | C | 09/19/2013 | no outside water piping or water piping under slab at this time | TED | TED | | PB | C | 4607352 |