SUNSET DREAM HOMES, INC | B= | C | 04/22/2014 | | DALE | DALE | | B= | C | 4724423 |
SUNSET RIDGE DREAM HOMES | B= | P | 04/21/2014 | Temp CO: to occupy ( Expires: 5/21/2014 12:00:00 AM) | REBECCA | REBECCA | | B= | P | 4723468 |
SUNSET DREAM HOMES, INC | B= | P | 04/17/2014 | Additional Inspections Required: External Agency Inspection F= by FIREDEPT is not Completed yet, Electrical Final Inspection is not Completed yet. insulate exposed foundation walls, exposed foam in basement needs at be covered with ignition barrier, address numbers on house -- Schedule a new Building Final when above items are complete. | CHRISM | CHRISM | | B= | P | 4722131 |
SUNSET RIDGE DREAM HOMES | BIN | C | 01/06/2014 | | DALE | DALE | | BIN | C | 4666893 |
SUNSET RIDGE DREAM HOMES | BFR | C | 01/06/2014 | truss eng. on file | DALE | DALE | | BFR | C | 4666892 |
SUNSET RIDGE DREAM HOMES | BFR | P | 12/30/2013 | could not find eng letter for truss repair, spraying foam inside | CHRISM | CHRISM | | BFR | P | 4664276 |
SUNSET RIDGE DREAM HOMES | BTR | C | 12/27/2013 | | DALE | DALE | | BTR | C | 4663113 |
SUNSET RIDGE DREAM HOMES | BFR | R | 12/20/2013 | ok to insulate, missing dbl H2.5s at all locations, eng repair for bottom cord T03, point load H03 girder, firestop above fireplace, | CHRISM | CHRISM | | BFR | R | 4661196 |
SUNSET RIDGE DREAM HOMES | BLA | C | 12/13/2013 | | DALE | DALE | | BLA | C | 4656509 |
SUNSET RIDGE DREAM HOMES | BSP | P | 11/01/2013 | porch frame ok | DALE | DALE | | BSP | P | 4634264 |
SUNSET RIDGE DREAM HOMES | BFI | C | 09/24/2013 | R-10 at walkout walls | CHRISM | CHRISM | | BFI | C | 4610083 |
SUNSET RIDGE DREAM HOMES | BFD | C | 09/24/2013 | soils on file drain usable isolate and float | CHRISM | CHRISM | | BFD | C | 4610082 |
SUNSET RIDGE DREAM HOMES | BFN | C | 09/24/2013 | design and eng report on file | CHRISM | CHRISM | | BFN | C | 4610081 |
SUNSET RIDGE DREAM HOMES | BFT | C | 09/24/2013 | eng report on file | CHRISM | CHRISM | | BFT | C | 4610078 |
SUNSET RIDGE DREAM HOMES | BFN | R | 09/19/2013 | paperwork not complete | CHRISM | CHRISM | | BFN | R | 4607425 |
SUNSET RIDGE DREAM HOMES | BFT | R | 09/19/2013 | paperwork not complete | CHRISM | CHRISM | | BFT | R | 4607424 |
HOMEOWNER | E= | C | 04/18/2014 | | JOSEPH | JOSEPH | | E= | C | 4723311 |
HOMEOWNER | E= | R | 04/17/2014 | Still need AFCI per 2011 nec ----------- spark rings in kitchen | JOSEPH | JOSEPH | | E= | R | 4722627 |
HOMEOWNER | E= | R | 04/16/2014 | Still missing afci breakers (install them where the 2011 code requires).------------- Neutral bonded to case at well disconnect------------ exterior outlets missing gfci protection------------- Install spark rings at outlets in cabinets----------- Reset for gfci for circulation pump can't be in the ceiling because it needs to be accessible. -------- Use TR type receptacles if below 5- 1/2 feet------- Blocking goes ABOVE cables NOT in front of cable.----------------------- note 30 amp breaker for ac unit is ok | JOSEPH | JOSEPH | | E= | R | 4721744 |
HOMEOWNER | E= | R | 04/10/2014 | complete reinspection required--------- too much to list--------- following is a partial list only------- in-use covers----------- WR type outlets -----------remove all panel knock outs in sub panel---------- panel directory---------- GFCI where requried-------------afci where required----------- inter system bonding terminal----------- expose ufer------------ outlet for cir pump---------- blocking---------- seal cables running through return air------ gfci within 6 feet of sink-----------too much to list----------notes ac is pre roughed----- call inspector at 327-2934 to go over inspection before recalling this | JOSEPH | JOSEPH | | E= | R | 4718258 |
HOMEOWNER | ES | C | 12/19/2013 | Residential Underground: 200 amp 3w new res meter in need to reseal | JOSEPH | JOSEPH | | ES | C | 4660637 |
HOMEOWNER | ER | C | 12/19/2013 | | JOSEPH | JOSEPH | | ER | C | 4660636 |
HOMEOWNER | ES | R | 12/18/2013 | Residential Underground: UFER should be # 4 cu | JOSEPH | JOSEPH | | ES | R | 4659736 |
HOMEOWNER | EP | C | 12/18/2013 | 100 amp sub panel ok | JOSEPH | JOSEPH | | EP | C | 4659735 |
HOMEOWNER | ER | R | 12/18/2013 | Add an outlet by the stairway railing. Lights in the stairwell are too low , 6' - 8" min height. Running boards.--------------Cage no ic rated fixtures. notes 2 - 6/3 al | JOSEPH | JOSEPH | | ER | R | 4659734 |
FRONT RANGE HEATING & COOLING | H= | C | 04/14/2014 | Correction made. | JEFFL | JEFFL | | H= | C | 4720030 |
FRONT RANGE HEATING & COOLING | H= | P | 04/11/2014 | Mech room lacks combustion air for two water heaters. Rest ok. | JEFFL | JEFFL | | H= | P | 4719098 |
FRONT RANGE HEATING & COOLING | HC | C | 12/18/2013 | RELEASE METER | JERRYF | JERRYF | | HC | C | 4659551 |
FRONT RANGE HEATING & COOLING | HRR | C | 12/18/2013 | CORRECTION MADE | JERRYF | JERRYF | | HRR | C | 4659550 |
FRONT RANGE HEATING & COOLING | HRR | P | 12/17/2013 | NEED INSULATION SHIELD ON FLUE - IS FIREPLACE FRAMING COMPLETE - NEED CONSULT WITH OTHER INSPECTOR ON HRR COMPLETION | JERRYF | JERRYF | | HRR | P | 4658797 |
FRONT RANGE HEATING & COOLING | HRR | P | 12/16/2013 | FIREPLACE NOT THROUGH ROOF | DAVIDH | DAVIDH | | HRR | P | 4657458 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | HI | C | 12/12/2013 | 10 LB TEST OK NOTE 1 1/4" LINE 1 FURN,F/P,BBQ ,GARAGE HEATER AND 2 W/H | DAVIDH | DAVIDH | | HI | C | 4655742 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | P= | C | 04/16/2014 | | TIM | TIM | | P= | C | 4721790 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | P= | P | 04/15/2014 | no access to kitchen or master bedroom wet floors rest ok r-p installed water cert to scanning | TIM | TIM | | P= | P | 4720872 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | PWO | C | 12/13/2013 | | JOEL | JOEL | | PWO | C | 4656666 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | PTO | C | 12/13/2013 | | JOEL | JOEL | | PTO | C | 4656664 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | PTO | P | 12/12/2013 | low test h2o | JOEL | JOEL | | PTO | P | 4655936 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | PB | C | 09/30/2013 | | TIM | TIM | | PB | C | 4613475 |