HOMEOWNER | B= | C | 06/26/2014 | | CHRISM | CHRISM | | B= | C | 4765928 |
HOMEOWNER | BLA | C | 02/26/2014 | | ED | ED | | BLA | C | 4693651 |
HOMEOWNER | BIN | C | 02/26/2014 | | ED | ED | | BIN | C | 4693650 |
HOMEOWNER | BFR | C | 02/26/2014 | engineer repair on file, items completed | ED | ED | | BFR | C | 4693648 |
HOMEOWNER | BFR | R | 02/18/2014 | ok to insulate, hanger missing F1, HTS20 missing C4A, TJI top cord notched need eng repair | CHRISM | CHRISM | | BFR | R | 4688861 |
HOMEOWNER | BSP | P | 02/07/2014 | porch roofs and posts ok, clearance at wood fireplaces ok | CHRISM | CHRISM | | BSP | P | 4684124 |
HOMEOWNER | BSP | R | 02/05/2014 | porch roofs, front porch missing H2.5s at rafters, rear porch nail off H2.5s | CHRISM | CHRISM | | BSP | R | 4683283 |
HOMEOWNER | BSP | P | 12/30/2013 | deck piers ok | CHRISM | CHRISM | | BSP | P | 4664282 |
HOMEOWNER | BSP | T | 11/18/2013 | PAID (REC#1171901) ADDITIONAL PLAN REVIEW TIME: $50 From: DANM Splice: Plan changes | DANM | DANM | | BSP | T | 4643512 |
HOMEOWNER | BFI | C | 10/22/2013 | R-10 at walkout walls ok | CHRISM | CHRISM | | BFI | C | 4626937 |
HOMEOWNER | BFD | C | 10/22/2013 | soils on file drain usable isolate and float | CHRISM | CHRISM | | BFD | C | 4626924 |
HOMEOWNER | BFN | C | 10/22/2013 | design and eng report on file | CHRISM | CHRISM | | BFN | C | 4626923 |
HOMEOWNER | BFT | C | 10/22/2013 | eng report on file | CHRISM | CHRISM | | BFT | C | 4626920 |
HOMEOWNER | BFN | P | 10/21/2013 | AUTHORIZED INSPECTION BY ENGINEER | TERRI | TERRI | TERRI | BFN | P | 4626280 |
HOMEOWNER | BFT | P | 10/21/2013 | AUTHORIZED INSPECTION BY ENGINEER | TERRI | TERRI | TERRI | BFT | P | 4626279 |
SOUTHERN COLORADO ELECTRIC INC. | E= | C | 06/16/2014 | no a/c | MATTHEW | MATTHEW | | E= | C | 4759055 |
SOUTHERN COLORADO ELECTRIC INC. | E= | R | 06/13/2014 | no power to master bedroom outlets, no power to outlets in garage room and by vent in garage, no power to disposal, lamp island lights, install correct cover at vacuum, #8nm on 50 amp breaker at steamer, missing dryer cover plate, install test light at OH door and x-mas light outlets | MATTHEW | MATTHEW | | E= | R | 4757928 |
SOUTHERN COLORADO ELECTRIC INC. | ES | C | 02/14/2014 | Residential Underground: 200 amp 3/w: new res----------- meter is set--- need seal | MATTHEW | MATTHEW | | ES | C | 4687760 |
SOUTHERN COLORADO ELECTRIC INC. | ER | C | 02/14/2014 | partial basement finish, #6al cooking equipment | MATTHEW | MATTHEW | | ER | C | 4687759 |
J D PLUMBING AND HEATING LLC | H= | C | 06/19/2014 | Final ok. direct vent boiler. | MARK | MARK | | H= | C | 4761506 |
J D PLUMBING AND HEATING LLC | HWP | C | 02/19/2014 | ok to cover 1st floor | TED | TED | | HWP | C | 4689421 |
J D PLUMBING AND HEATING LLC | HC | C | 01/28/2014 | RELEASE METER | MICHAELS | MICHAELS | | HC | C | 4678708 |
J D PLUMBING AND HEATING LLC | HI | C | 01/28/2014 | 10# test ok. 2lb. 1 1/4" main to boiler, 2-dryers, fp, bbq, c-top, future pit. | MICHAELS | MICHAELS | | HI | C | 4678707 |
HOMEOWNER | HRR | C | 01/28/2014 | Rough ok. Note: FB, radiant heat. | MICHAELS | MICHAELS | | HRR | C | 4678703 |
HOMEOWNER | HWP | P | 10/28/2013 | ok to cover basement | TED | TED | | HWP | P | 4630211 |
HOMEOWNER | P= | C | 06/18/2014 | NOTE : FINISHED BASEMENT . NO IRRIGATION . POTABLE WATER CERT TO SCANNING | GABE | GABE | | P= | C | 4760280 |
J D PLUMBING AND HEATING LLC | PTO | C | 01/28/2014 | finished basement | JOEL | JOEL | | PTO | C | 4678789 |
HOMEOWNER | PWO | C | 10/24/2013 | need certificate of potable water by final | TED | TED | | PWO | C | 4629052 |
J D PLUMBING AND HEATING LLC | PB | C | 10/24/2013 | | TED | TED | | PB | C | 4629050 |
HOMEOWNER | PWO | R | 10/22/2013 | no tracer wire run along new line | TED | TED | | PWO | R | 4626941 |