CUSTOM DESIGN BUILDERS, INC | B= | C | 04/11/2014 | All other required Final inspections are complete. (This is a computer generated result) | CHRISM | CHRISM | | B= | C | 4719355 |
CUSTOM DESIGN BUILDERS, INC | B= | P | 04/11/2014 | Additional Inspections Required: Electrical Final Inspection is not Completed yet. | CHRISM | CHRISM | | B= | P | 4718980 |
CUSTOM DESIGN BUILDERS, INC | B= | P | 04/10/2014 | Additional Inspections Required: Electrical Final Inspection is not Completed yet, Mechanical Final Inspection is not Completed yet. ok after other finals -- Schedule a new Building Final when above items are complete. | CHRISM | CHRISM | | B= | P | 4717916 |
CUSTOM DESIGN BUILDERS, INC | BSP | T | 04/09/2014 | PAID (REC#1188318) PLAN SPLICE FEE: $50 by: TCRIPPEN for Mechanical: new splice changing heat runs | TCRIPPEN | TCRIPPEN | | BSP | T | 4716978 |
CUSTOM DESIGN BUILDERS, INC | BLA | C | 02/13/2014 | | CHRISM | CHRISM | | BLA | C | 4686616 |
CUSTOM DESIGN BUILDERS, INC | BLA | R | 02/12/2014 | extend all electric boxes to front of stucco not just at popouts | CHRISM | CHRISM | | BLA | R | 4685819 |
CUSTOM DESIGN BUILDERS, INC | BLA | R | 01/29/2014 | extend eletrical boxes to front of stucco | CHRISM | CHRISM | | BLA | R | 4679720 |
CUSTOM DESIGN BUILDERS, INC | BIN | C | 01/21/2014 | | CHRISM | CHRISM | | BIN | C | 4675181 |
CUSTOM DESIGN BUILDERS, INC | BFR | C | 01/21/2014 | | CHRISM | CHRISM | | BFR | C | 4675163 |
CUSTOM DESIGN BUILDERS, INC | BSP | P | 01/15/2014 | did frame walk / pipe jacks for dry in / anchor bolts / fireblock garage door brackets / glue shims under i beams basement / remove float blocks at stair walls | JOHN | JOHN | | BSP | P | 4672410 |
CUSTOM DESIGN BUILDERS, INC | BSP | P | 12/12/2013 | deck and deck cover and posts ok | CHRISM | CHRISM | | BSP | P | 4655858 |
CUSTOM DESIGN BUILDERS, INC | BSP | R | 12/04/2013 | deck piers ok, missing H2.5s at rear porch roof | CHRISM | CHRISM | | BSP | R | 4652447 |
CUSTOM DESIGN BUILDERS, INC | BFI | C | 10/25/2013 | | CHRISM | CHRISM | | BFI | C | 4629324 |
CUSTOM DESIGN BUILDERS, INC | BFD | C | 10/25/2013 | | CHRISM | CHRISM | | BFD | C | 4629323 |
CUSTOM DESIGN BUILDERS, INC | BFN | C | 10/25/2013 | design on file | CHRISM | CHRISM | | BFN | C | 4629316 |
CUSTOM DESIGN BUILDERS, INC | BFN | P | 10/24/2013 | eng letter on file, need foundation design for file | CHRISM | CHRISM | | BFN | P | 4628499 |
CUSTOM DESIGN BUILDERS, INC | BFT | C | 10/24/2013 | eng report on file | CHRISM | CHRISM | | BFT | C | 4628494 |
CUSTOM DESIGN BUILDERS, INC | BFI | P | 10/21/2013 | R-10 at walkout walls ok | CHRISM | CHRISM | | BFI | P | 4626338 |
CUSTOM DESIGN BUILDERS, INC | BFD | P | 10/18/2013 | soils and open hole on file, drain usable isolate and float, need to clear bft and bfn, no insulation at walkkout walls at this time | CHRISM | CHRISM | | BFD | P | 4625544 |
CURTIS ELECTRICAL CONTRACTORS LLC | E= | C | 04/11/2014 | | MATTHEW | MATTHEW | | E= | C | 4719354 |
CURTIS ELECTRICAL CONTRACTORS LLC | E= | R | 04/10/2014 | need gfci protection for ice melt, need permit for detached garage | MATTHEW | MATTHEW | | E= | R | 4717938 |
CURTIS ELECTRICAL CONTRACTORS LLC | E= | R | 04/08/2014 | provide means to check outlets at soffits, need in-use cover under soffit, need oven disconnect, provide working clearance at water heater disconnect, a/c breaker too small, gfci outlet in master toilet area, ground dining room light, afci mud room and sun room, remove low volt xfmr and low volt wiring from sub-panel, staple nm above sub-panel, guard crawler lights-------------- need separate permit for garage (i did not inspect garage or underground to garage) | MATTHEW | MATTHEW | | E= | R | 4716311 |
CURTIS ELECTRICAL CONTRACTORS LLC | ER | C | 01/16/2014 | no mcc's----------- cabinets and headboards being installed---- contractor needs to verify outlet location by final | MATTHEW | MATTHEW | | ER | C | 4672940 |
CURTIS ELECTRICAL CONTRACTORS LLC | ER | R | 01/15/2014 | add outlets (bedrooms, bottom of stairs), nail plate at master toilet and land nm in outlet box same area, staple nm above panel, install running boards, what are the 12-2 stubs at exterior?, trim attic, land branch circuits and make up sub-panels ------------------- finished basement----- check mcc's at re-inspect when panels are made up | MATTHEW | MATTHEW | | ER | R | 4672418 |
CURTIS ELECTRICAL CONTRACTORS LLC | EUG | C | 11/21/2013 | ok from pole to house | BRIAN | BRIAN | | EUG | C | 4646335 |
CURTIS ELECTRICAL CONTRACTORS LLC | ES | C | 10/30/2013 | Residential Overhead: 200 amp 3/w: new res------------ need meter set------------------------- inspector note: inspection is for panel on pole only: no outlets installed at this time and no underground | MATTHEW | MATTHEW | | ES | C | 4632587 |
ADVANTAGE HEATING AND COOLING | H= | C | 04/10/2014 | Notes-- direct furnace x 2.. direct vent water heater. Equipment cert to scan. | JEFFL | JEFFL | | H= | C | 4718096 |
ADVANTAGE HEATING AND COOLING | HC | C | 12/24/2013 | RELEASE METER | MARK | MARK | | HC | C | 4662557 |
ADVANTAGE HEATING AND COOLING | HRR | C | 12/24/2013 | Rough is ok. Duct design does not match prints. Note: The following need to be changed with regional regarding duct design, by final: Added heat run in b/r#2. Change from 5" h/r to 7" by stairs at main level. Removal of 5" h/r above b/r#3 for room off of garage. Will need a duct leakage report by final and termination of direct vent furnaces and powered vent w/h. Will also need equipment docs by final. | MARK | MARK | | HRR | C | 4662555 |
ADVANTAGE HEATING AND COOLING | HRR | R | 12/20/2013 | NOT READY WAIVED TRIP FEE | DAVIDH | DAVIDH | | HRR | R | 4660898 |
HODGES PLUMBING INC | HI | C | 12/19/2013 | 10 LB TEST OK NOTE 1 1/2" LINE 2 FURN,1 F/P,W/H,C/T,PATIO HEATER AND FUTURE GARAGE HEATER | DAVIDH | DAVIDH | | HI | C | 4659945 |
G & L PLUMBING | P= | C | 04/03/2014 | | GABE | GABE | | P= | C | 4714110 |
G & L PLUMBING | PTO | C | 12/18/2013 | | TIM | TIM | | PTO | C | 4659589 |
CUSTOM DESIGN BUILDERS, INC | PWO | C | 11/07/2013 | | JOEL | JOEL | | PWO | C | 4637544 |
CUSTOM DESIGN BUILDERS, INC | PWO | P | 10/29/2013 | need backflow for yard hydrant | TIM | TIM | | PWO | P | 4631101 |
G & L PLUMBING | PB | C | 10/25/2013 | basement ok, note: check crawlspace at pto | TED | TED | | PB | C | 4629618 |