BELLA VITA CUSTOM HOMES | B= | C | 06/05/2014 | | CHRISM | CHRISM | | B= | C | 4752110 |
BELLA VITA CUSTOM HOMES | B= | R | 06/04/2014 | at deck need landing at door | DALE | DALE | | B= | R | 4751018 |
BELLA VITA CUSTOM HOMES | BIN | C | 05/29/2014 | attic insulation ok | CHRISM | CHRISM | | BIN | C | 4747964 |
BELLA VITA CUSTOM HOMES | BLA | C | 04/24/2014 | | CHRISM | CHRISM | | BLA | C | 4726491 |
BELLA VITA CUSTOM HOMES | BFR | P | 04/09/2014 | egress windows ok, stairs ok, need to fix headroom not 6'8" | CHRISM | CHRISM | | BFR | P | 4717251 |
BELLA VITA CUSTOM HOMES | BIN | P | 04/09/2014 | insulation ok, clear BFR | CHRISM | CHRISM | | BIN | P | 4717235 |
BELLA VITA CUSTOM HOMES | BFR | P | 04/07/2014 | ok to insulate, stairs not per code, egress sill hieght in basement bedrooms over 44" | CHRISM | CHRISM | | BFR | P | 4715497 |
BELLA VITA CUSTOM HOMES | BFR | R | 04/04/2014 | dont insulate, strongback gables, walls on garage slab need to float, dbl H2.5s at greenhouse trusses, tie off all laterlas, missing laterals EF1 and F12, MST12s at HG girder, repair to truss A sould include top cord and gusset on web, stair configuration not per code, egress windows in basement bedrooms 44" max, float blocks, point load girders | CHRISM | CHRISM | | BFR | R | 4714976 |
BELLA VITA CUSTOM HOMES | BTR | C | 01/16/2014 | | CHRISM | CHRISM | | BTR | C | 4673079 |
BELLA VITA CUSTOM HOMES | BFI | C | 11/09/2013 | R-10 at walkout | CHRISM | CHRISM | | BFI | C | 4638891 |
BELLA VITA CUSTOM HOMES | BFD | C | 11/09/2013 | soils on file drain usable isolate and float | CHRISM | CHRISM | | BFD | C | 4638890 |
BELLA VITA CUSTOM HOMES | BFN | P | 11/09/2013 | eng report on file need clean co[py of foundation design no highlighter | CHRISM | CHRISM | | BFN | P | 4638889 |
BELLA VITA CUSTOM HOMES | BFT | C | 11/09/2013 | eng report on file | CHRISM | CHRISM | | BFT | C | 4638888 |
H&H ELECTRICAL SERVICE | E= | C | 06/03/2014 | | MATTHEW | MATTHEW | | E= | C | 4750337 |
H&H ELECTRICAL SERVICE | E= | R | 06/02/2014 | garage gfci test needs to be readily accessible------ check for brass floor box covers at re-inspect | MATTHEW | MATTHEW | | E= | R | 4749395 |
H&H ELECTRICAL SERVICE | E= | L | 05/30/2014 | locked 4:57 | MATTHEW | MATTHEW | | E= | L | 4748882 |
H&H ELECTRICAL SERVICE | E= | R | 05/29/2014 | vacuum outlet in garage not gfi ------------- afci mech room lights because it feeds the hallway light in front of bed room --------- install blank in panel | CRAIG | CRAIG | | E= | R | 4747982 |
H&H ELECTRICAL SERVICE | E= | R | 05/27/2014 | receptacle in garage needs gfi protection , bad outlet on island , receptacle spacing by walk - out door in dining room , AFCI lower rec room lighting | TOMC | TOMC | | E= | R | 4745884 |
H&H ELECTRICAL SERVICE | EUG | C | 04/08/2014 | service lateral from ped to home | MATTHEW | MATTHEW | | EUG | C | 4716513 |
H&H ELECTRICAL SERVICE | ES | C | 04/08/2014 | Residential Underground: 200 amp 3/w: new res---- meter is set; need seal | MATTHEW | MATTHEW | | ES | C | 4716506 |
H&H ELECTRICAL SERVICE | EUG | R | 04/03/2014 | ditch filled to top with snow | MATTHEW | MATTHEW | | EUG | R | 4714164 |
H&H ELECTRICAL SERVICE | ES | R | 04/03/2014 | not ready | MATTHEW | MATTHEW | | ES | R | 4714157 |
H&H ELECTRICAL SERVICE | ER | C | 03/10/2014 | whips for under counter lights and bath room lights and over door lights ---------------------- no mcc 3 - 10 3 to oven / dryer / outlet 6/3 al to range 4/w # 2al to sub panel in finished basement | CRAIG | CRAIG | | ER | C | 4699749 |
ATLANTIC HEATING & A/C INC | H= | C | 06/02/2014 | 2LB LETTER RECEIVED - ALL OK | JERRYF | JERRYF | | H= | C | 4748933 |
ATLANTIC HEATING & A/C INC | H= | L | 05/30/2014 | LOCKED AT 4:15 - REG. AT HOUSE - NEED 2LB APPROVAL LETTER FROM GAS PURVEYOR - 2/10 OF A MILE TO HOUSE FROM METER - GAS STUB FOR FUTURE FREE STANDING STOVE IN BASEMENT IS OK - FREE STANDING STOVE WILL NEED PERMITS AND INSPECTIONS WHEN INSTALLED -ALL OK PENDING GAS LETTER | JERRYF | JERRYF | | H= | L | 4748837 |
ATLANTIC HEATING & A/C INC | H= | P | 05/29/2014 | Vent terminations are completed, but per email regarding stove vent needing to be added, and inspected, I will leave this as a partial until the vent is ready for inspection. Not there at time of today's final. | MARK | MARK | | H= | P | 4747511 |
ATLANTIC HEATING & A/C INC | H= | R | 05/27/2014 | Vent not completed. Still working on roof. | MARK | MARK | | H= | R | 4745716 |
ATLANTIC HEATING & A/C INC | H= | R | 05/14/2014 | not ready, need to complete roof so vents can be completed, complete inside flooring for access, reinspect all | TED | TED | | H= | R | 4738568 |
ATLANTIC HEATING & A/C INC | HC | C | 04/02/2014 | RELEASE METER | JEFFL | JEFFL | | HC | C | 4713278 |
ATLANTIC HEATING & A/C INC | HRR | C | 04/02/2014 | Corrections made. | JEFFL | JEFFL | | HRR | C | 4713273 |
FOREST PLUMBING | HWP | P | 03/21/2014 | Test is good, ok to cover. | MARK | MARK | | HWP | P | 4706613 |
ATLANTIC HEATING & A/C INC | HRR | P | 03/20/2014 | Need a nail plate for dryer vent and main level bath vents need to be insulated all the way to the box. Vent for free standing f/p will need to be inspected before rough inspection can be completed. Rest ok. | MARK | MARK | | HRR | P | 4705948 |
KAMPP-L ENTERPRISES, INC. | HI | C | 03/20/2014 | 10lb test ok. Note: 1 1/2" main. Boiler, f/p, rng, bbq. | MARK | MARK | | HI | C | 4705940 |
KAMPP-L ENTERPRISES, INC. | HO | C | 03/11/2014 | 10 lb test is good. Note: 2" PE to riser @ house. | MARK | MARK | | HO | C | 4700303 |
FOREST PLUMBING | HWP | P | 02/18/2014 | ok to cover garage and sun room | TED | TED | | HWP | P | 4688338 |
FOREST PLUMBING | HWP | P | 01/15/2014 | 60 LB TEST OK NOTE OK TO POUR | DAVIDH | DAVIDH | | HWP | P | 4672539 |
B & L PLUMBING, INC. | P= | C | 05/23/2014 | NOTE : RP IN BASEMENT FOR HYDRANT , NO IRRIGATION . FINISHED BASEMENT | GABE | GABE | | P= | C | 4744600 |
BELLA VITA CUSTOM HOMES | PWO | C | 03/17/2014 | certificate of potable water sent to scanning. | DICK | DICK | | PWO | C | 4703914 |
B & L PLUMBING, INC. | PTO | C | 02/03/2014 | finished basement | JOEL | JOEL | | PTO | C | 4682051 |
FOREST PLUMBING | PB+ | C | 01/22/2014 | | JOEL | JOEL | | PB+ | C | 4675885 |
FOREST PLUMBING | PB | C | 12/27/2013 | | TED | TED | | PB | C | 4663080 |