VANTAGE HOMES CORP. | B= | C | 02/07/2014 | All other required Final inspections are complete. (This is a computer generated result) | CHRISM | CHRISM | | B= | C | 4684029 |
VANTAGE HOMES CORP. | B= | P | 01/29/2014 | Additional Inspections Required: External Agency Inspection HD= by HEALTHDEPT is not Completed yet. finished basement | CHRISM | CHRISM | | B= | P | 4679819 |
VANTAGE HOMES CORP. | BLA | C | 11/18/2013 | | CHRISM | CHRISM | | BLA | C | 4643546 |
VANTAGE HOMES CORP. | BLA | C | 11/15/2013 | | CHRISM | CHRISM | | BLA | C | 4642606 |
VANTAGE HOMES CORP. | BIN | C | 11/15/2013 | finished basement | CHRISM | CHRISM | | BIN | C | 4642605 |
VANTAGE HOMES CORP. | BFR | C | 11/15/2013 | | CHRISM | CHRISM | | BFR | C | 4642604 |
VANTAGE HOMES CORP. | BFR | R | 11/14/2013 | ok to insulate, missed lateral brace and H2.5s on C2 trusses | CHRISM | CHRISM | | BFR | R | 4641835 |
VANTAGE HOMES CORP. | BSP | P | 10/29/2013 | narrow braced walls framing ok, rear porch roof ok, front porch and posts ok | CHRISM | CHRISM | | BSP | P | 4631399 |
VANTAGE HOMES CORP. | BFD | C | 10/15/2013 | soils on file drain usable isolate and float | CHRISM | CHRISM | | BFD | C | 4622797 |
VANTAGE HOMES CORP. | BFN | C | 10/15/2013 | design and eng report on file | CHRISM | CHRISM | | BFN | C | 4622796 |
VANTAGE HOMES CORP. | BFT | C | 10/15/2013 | eng report on file | CHRISM | CHRISM | | BFT | C | 4622794 |
VANTAGE HOMES CORP. | BFN | P | 10/15/2013 | AUTHORIZED INSPECTION BY ENGINEER | JESSICA | JESSICA | JESSICA | BFN | P | 4622438 |
VANTAGE HOMES CORP. | BFT | P | 10/15/2013 | AUTHORIZED INSPECTION BY ENGINEER | JESSICA | JESSICA | JESSICA | BFT | P | 4622437 |
D & J QUALITY ELECTRIC INC | E= | C | 01/21/2014 | 20 amp a/c ok------- hot tub pre-wire | MATTHEW | MATTHEW | | E= | C | 4675093 |
D & J QUALITY ELECTRIC INC | E= | R | 01/16/2014 | afci outlet outside laundry room, neutral rebonded to ground at a/c disconnect (attach ground to ground bar), no power to basement CO detector, need #2 grounding electrode conductor as requested at time of service inspection------------------ 20 amp a/c ok | MATTHEW | MATTHEW | | E= | R | 4672999 |
D & J QUALITY ELECTRIC INC | ES | C | 11/12/2013 | Residential Underground: 200 amp 3/w: new res: meter is set; need seal --------------------------------------------- need #2cu grounding electrode conductor by final; 350 kcmil service conductors -------------------------------------- | MATTHEW | MATTHEW | | ES | C | 4639665 |
D & J QUALITY ELECTRIC INC | ER | C | 11/12/2013 | finished basement, 6-3 nm to hot tub, 8-3 to cooking equipment | MATTHEW | MATTHEW | | ER | C | 4639657 |
D & J QUALITY ELECTRIC INC | EUG | C | 10/25/2013 | service lateral | MATTHEW | MATTHEW | | EUG | C | 4629840 |
ATLANTIC HEATING & A/C INC | H= | C | 01/14/2014 | OK NOTE A/C | DAVIDH | DAVIDH | | H= | C | 4671212 |
ATLANTIC HEATING & A/C INC | HC | C | 11/13/2013 | RELEASE METER | DAVIDH | DAVIDH | | HC | C | 4640408 |
ATLANTIC HEATING & A/C INC | HRR | C | 11/13/2013 | CORRECTIONS MADE | DAVIDH | DAVIDH | | HRR | C | 4640407 |
ATLANTIC HEATING & A/C INC | HRR | P | 11/12/2013 | DOWNSTAIRS BEDROOM S/A UP NEEDS SEALED REST OK NOTE 6" OSA FINISHED BASEMENT SCANNED PERFORMANCE REPORT | DAVIDH | DAVIDH | | HRR | P | 4639436 |
L & L GAS SHOP, LLC. | HI | C | 11/07/2013 | 1 1/4'' furnace, w/h, fireplace, range | TED | TED | | HI | C | 4637627 |
TEAM PLUMBING, INC. | P= | C | 01/15/2014 | | JOEL | JOEL | | P= | C | 4672388 |
TEAM PLUMBING, INC. | P= | P | 01/14/2014 | leak under bar sink | JOEL | JOEL | | P= | P | 4671429 |
HOMEOWNER | PWO | C | 12/16/2013 | | TIM | TIM | | PWO | C | 4657779 |
TEAM PLUMBING, INC. | PTO | C | 11/13/2013 | | JOEL | JOEL | | PTO | C | 4640998 |
TEAM PLUMBING, INC. | PTO | P | 11/12/2013 | low test dwv laundry | JOEL | JOEL | | PTO | P | 4639819 |
TEAM PLUMBING, INC. | PB | C | 10/21/2013 | | TED | TED | | PB | C | 4626087 |