CARPENTER'S SON CONSTRUCTION | B= | C | 05/08/2014 | | CHRISM | CHRISM | | B= | C | 4735166 |
CARPENTER'S SON CONSTRUCTION | BIN | C | 02/10/2014 | | JOHNP | JOHNP | | BIN | C | 4684972 |
CARPENTER'S SON CONSTRUCTION | BFR | C | 02/10/2014 | | JOHNP | JOHNP | | BFR | C | 4684971 |
CARPENTER'S SON CONSTRUCTION | BFR | R | 02/04/2014 | ok to insulate missing H2.5s at interior bearing trusses | CHRISM | CHRISM | | BFR | R | 4682769 |
CARPENTER'S SON CONSTRUCTION | BLA | C | 01/21/2014 | | CHRISM | CHRISM | | BLA | C | 4674870 |
CARPENTER'S SON CONSTRUCTION | BSP | P | 01/07/2014 | front porch and posts ok | CHRISM | CHRISM | | BSP | P | 4667612 |
CARPENTER'S SON CONSTRUCTION | BSP | R | 12/23/2013 | missing LS30's at J1 truss, post connections not per plan detail, need engineering for (2)lag bolted connections at post to beam | ED | ED | | BSP | R | 4662131 |
CARPENTER'S SON CONSTRUCTION | BFD | C | 12/23/2013 | | ED | ED | | BFD | C | 4662107 |
CARPENTER'S SON CONSTRUCTION | BFN | C | 12/23/2013 | design on file | ED | ED | | BFN | C | 4662106 |
CARPENTER'S SON CONSTRUCTION | BFD | P | 10/25/2013 | drain ok, soils on file, clear bfn, drain usable isolate and float | CHRISM | CHRISM | | BFD | P | 4629481 |
CARPENTER'S SON CONSTRUCTION | BFN | P | 10/25/2013 | eng report on file, need copy of foundation design for file | CHRISM | CHRISM | | BFN | P | 4629476 |
CARPENTER'S SON CONSTRUCTION | BFT | C | 10/25/2013 | eng report on file | CHRISM | CHRISM | | BFT | C | 4629472 |
BLUE MOUNTAIN ELECTRIC, INC. | E= | C | 04/17/2014 | a/c ok 30 amp | CRAIG | CRAIG | | E= | C | 4722628 |
BLUE MOUNTAIN ELECTRIC, INC. | E= | R | 04/15/2014 | trim kitchen sink light and master bath light, gfci master toilet outlet, turn spa outlet toward opening (crawler), enclose master closet light, gfci all outlets within 6' of laundry sink, mixed travellers at entry and living room lights, over hang at island too far, afci low volt closet by bedrooms, strap riser at pole, install inter-system bond terminal, wire a/c, missing cover in mech room, wire pumps and water heater correctly (connectors and protect nm), verify hall outlet not buried | MATTHEW | MATTHEW | | E= | R | 4720862 |
BLUE MOUNTAIN ELECTRIC, INC. | ES | C | 04/15/2014 | Residential Overhead: 200 amp 3/w: new res---- meter is set: need seal | MATTHEW | MATTHEW | | ES | C | 4720858 |
BLUE MOUNTAIN ELECTRIC, INC. | ER | C | 01/28/2014 | | MIKEC | MIKEC | | ER | C | 4678491 |
BLUE MOUNTAIN ELECTRIC, INC. | EUG | C | 01/22/2014 | 4/0 urd from pole to house # 2 urd + #6 eg to garage | TOMC | TOMC | | EUG | C | 4676299 |
FOREST PLUMBING | H= | C | 05/02/2014 | OK. NOTES: DIRECT VENT BOILER - REST OK - FP MANTEL OK | JERRYF | JERRYF | | H= | C | 4731997 |
BRUNO'S HEATING & COOLING | H= | C | 05/02/2014 | OK. NOTES: FP MANTEL OK | JERRYF | JERRYF | | H= | C | 4731996 |
FOREST PLUMBING | H= | L | 05/01/2014 | UNABLE TO ACCESS DUE TO ROAD REPAIR | JERRYF | JERRYF | | H= | L | 4731055 |
BRUNO'S HEATING & COOLING | H= | P | 04/15/2014 | Mantle not complete at fireplace. Boiler not complete. Unable to enter laundry room - fresh grout. Reinspect all. | JEFFL | JEFFL | | H= | P | 4720722 |
FOREST PLUMBING | HWP | C | 02/20/2014 | ok to cover in floor piping | TED | TED | | HWP | C | 4690353 |
BRUNO'S HEATING & COOLING | HRR | C | 02/03/2014 | OK NOTE AIR HANDLER ,EXHAUST VENTS,BOILER VENT , DRYER VENT , F/P VENT AND A/C DUCT WORK | DAVIDH | DAVIDH | | HRR | C | 4681916 |
BRUNO'S HEATING & COOLING | HRR | R | 01/29/2014 | DUCT DESIGN PLANS ARE NOT BY FIREPLACE NO EQUIP SET | DAVIDH | DAVIDH | | HRR | R | 4679973 |
FOREST PLUMBING | HC | C | 01/22/2014 | RELEASE METER REQUESTING 2 LB | DAVIDH | DAVIDH | | HC | C | 4675900 |
FOREST PLUMBING | HO | C | 01/22/2014 | 10 LB TEST OK NOTE OK TO COVER | DAVIDH | DAVIDH | | HO | C | 4675899 |
FOREST PLUMBING | HI | C | 01/22/2014 | 10 LB TEST OK NOTE 1 BOILER,BBQ,AND F/P | DAVIDH | DAVIDH | | HI | C | 4675893 |
FOREST PLUMBING | P= | C | 04/22/2014 | CORRECTIONS MADE | GABE | GABE | | P= | C | 4724790 |
FOREST PLUMBING | P= | P | 04/21/2014 | CHANGE WATER LINES ON MASTER TUB , LEAK AT SHOWER HEAD IN GUEST , NOTE: CERTIFICATE OF POTABLE WATER TO SCANNING | GABE | GABE | | P= | P | 4723613 |
FOREST PLUMBING | PTO | C | 01/28/2014 | | JOEL | JOEL | | PTO | C | 4678836 |
CARPENTER'S SON CONSTRUCTION | PWO | C | 01/09/2014 | | JOEL | JOEL | | PWO | C | 4669069 |
FOREST PLUMBING | PB | C | 10/30/2013 | | TIM | TIM | | PB | C | 4632597 |