WALLACE CONSTRUCTION SERVICES INC | B= | C | 07/25/2014 | All other required Final inspections are complete. (This is a computer generated result) | DALE | DALE | | B= | C | 4784581 |
WALLACE CONSTRUCTION SERVICES INC | B= | P | 07/24/2014 | Additional Inspections Required: External Agency Inspection F= by FIREDEPT is not Completed yet. finished basement, deck in | DALE | DALE | | B= | P | 4783472 |
WALLACE CONSTRUCTION SERVICES INC | BSP | P | 07/23/2014 | For Building final per Chris M. / Need egress ladders secured in to window wells / Need guard rail for deck and inside stairs installed / Need hand rail for deck stairs / bathroom fan in main level bathroom installed / Need ladder to see insulation in attic / Plumbing final not complete | NICK | NICK | | BSP | P | 4782302 |
WALLACE CONSTRUCTION SERVICES INC | BFR | C | 05/06/2014 | deck and porch posts ok | CHRISM | CHRISM | | BFR | C | 4733349 |
WALLACE CONSTRUCTION SERVICES INC | BIN | C | 03/24/2014 | finished basement | CHRISM | CHRISM | | BIN | C | 4707559 |
WALLACE CONSTRUCTION SERVICES INC | BFR | R | 03/11/2014 | ok to insulate, windbrace gables, dbl H2.5s on hip masters | CHRISM | CHRISM | | BFR | R | 4700460 |
WALLACE CONSTRUCTION SERVICES INC | BLA | C | 02/28/2014 | | CHRISM | CHRISM | | BLA | C | 4694896 |
WALLACE CONSTRUCTION SERVICES INC | BSP | P | 02/14/2014 | move electric panels out of common walls or rock behind | CHRISM | CHRISM | | BSP | P | 4687336 |
WALLACE CONSTRUCTION SERVICES INC | BSP | P | 01/30/2014 | lath on gables ok | CHRISM | CHRISM | | BSP | P | 4680436 |
WALLACE CONSTRUCTION SERVICES INC | BTR | C | 01/21/2014 | | CHRISM | CHRISM | | BTR | C | 4675041 |
WALLACE CONSTRUCTION SERVICES INC | BFD | C | 11/05/2013 | stamped open hole on file | CHRISM | CHRISM | | BFD | C | 4636193 |
WALLACE CONSTRUCTION SERVICES INC | BFI | C | 11/04/2013 | | CHRISM | CHRISM | | BFI | C | 4634983 |
WALLACE CONSTRUCTION SERVICES INC | BFD | R | 11/04/2013 | no stamped open hole on site | CHRISM | CHRISM | | BFD | R | 4634975 |
WALLACE CONSTRUCTION SERVICES INC | BFN | C | 10/29/2013 | design and soils on file, stamped open hole at drain | CHRISM | CHRISM | | BFN | C | 4631338 |
WALLACE CONSTRUCTION SERVICES INC | BFT | C | 10/23/2013 | 5000# bearing pads ok | CHRISM | CHRISM | | BFT | C | 4627563 |
HAMILTON ELECTRIC, LLC | E= | C | 07/14/2014 | | MATTHEW | MATTHEW | | E= | C | 4776389 |
HAMILTON ELECTRIC, LLC | E= | R | 07/11/2014 | Panel blanks at sub panel in garage----------GFCI protection for outlets in mech room ----------- Cage open bulb in mech room (under insulation)-------------- Notes no ac pre rough | JOSEPH | JOSEPH | | E= | R | 4775630 |
HAMILTON ELECTRIC, LLC | EP | C | 07/11/2014 | 200 amp sub panel and 70 amp sub ok | JOSEPH | JOSEPH | | EP | C | 4775622 |
HAMILTON ELECTRIC, LLC | ES | C | 03/03/2014 | Residential Underground: completed 2-26 | MATTHEW | MATTHEW | | ES | C | 4695800 |
HAMILTON ELECTRIC, LLC | ER | C | 03/03/2014 | finished basement | MATTHEW | MATTHEW | | ER | C | 4695798 |
HAMILTON ELECTRIC, LLC | ES | C | 02/26/2014 | Residential Underground: 200 amp 3/w: new res--------- no action needed | MATTHEW | MATTHEW | | ES | C | 4693661 |
HAMILTON ELECTRIC, LLC | ER | R | 02/26/2014 | finish framing in basement powder room, lower electrical boxes and staple in basement bedroom closet, ground screws exterior pan boxes, trim attic, make up ex-fan main level | MATTHEW | MATTHEW | | ER | R | 4693658 |
HAMILTON ELECTRIC, LLC | EUG | C | 02/12/2014 | 200 amp feeder from pole to house | MATTHEW | MATTHEW | | EUG | C | 4686001 |
HAMILTON ELECTRIC, LLC | ES | R | 02/12/2014 | not ready--- panel in fire wall | MATTHEW | MATTHEW | | ES | R | 4685995 |
CORNERSTONE PLUMBING INC | H= | C | 07/14/2014 | Note-- direct vent boiler. | JEFFL | JEFFL | | H= | C | 4776101 |
BLACK FOREST HEATING | HC | C | 03/10/2014 | RELEASE METER | MARK | MARK | | HC | C | 4700004 |
BLACK FOREST HEATING | HRR | C | 03/10/2014 | Rough inspection ok. Note: Need make up air to laundry at final, check c/a to mech at final. | MARK | MARK | | HRR | C | 4699971 |
CORNERSTONE PLUMBING INC | HI | C | 02/27/2014 | Hard piped into cabinet. 10lb test ok. | MARK | MARK | | HI | C | 4694167 |
CORNERSTONE PLUMBING INC | HI | R | 02/25/2014 | can not run gas flex connector at fireplace in concealed location, must be hard piped from loose key valve into fireplace cabinet, note: 1 1/4'' boiler, fireplace, bbq | TED | TED | | HI | R | 4692974 |
CORNERSTONE PLUMBING INC | HWP | C | 01/30/2014 | | JOEL | JOEL | | HWP | C | 4680637 |
CORNERSTONE PLUMBING INC | HWP | P | 01/29/2014 | 50# test for upper floor piping only, piping in basement to bath and kitchen area not complete | JOEL | JOEL | | HWP | P | 4680009 |
CORNERSTONE PLUMBING INC | HWP | P | 12/05/2013 | 50# test ok. Basement under slab. | MICHAELS | MICHAELS | | HWP | P | 4653115 |
CORNERSTONE PLUMBING INC | P= | C | 07/14/2014 | NOTE : FINISHED BASEMENT . NO IRRIGATION . POTABLE WATER CERT TO SCANNING | GABE | GABE | | P= | C | 4776077 |
CORNERSTONE PLUMBING INC | P= | P | 07/09/2014 | NO HOT WATER . POTABLE WATER CERT REQUIRED FOR FINAL | GABE | GABE | | P= | P | 4773230 |
CORNERSTONE PLUMBING INC | PTO | C | 01/30/2014 | | JOEL | JOEL | | PTO | C | 4680629 |
CORNERSTONE PLUMBING INC | PTO | R | 01/29/2014 | waive trip fee, h2o service across basement still not tested | JOEL | JOEL | | PTO | R | 4679999 |
CORNERSTONE PLUMBING INC | PTO | P | 01/21/2014 | freeze protect h2o lines in garage wall for hose bibb, test water service thru the house and irrigation line. note: finished basement | JOEL | JOEL | | PTO | P | 4675098 |
HOMEOWNER | PWO | C | 11/15/2013 | need certificate of potable water by final | TED | TED | | PWO | C | 4642594 |
CORNERSTONE PLUMBING INC | PB | C | 11/08/2013 | no h2o | JOEL | JOEL | | PB | C | 4638578 |