HAMMER HOMES, INC. | B= | C | 06/24/2014 | | CHRISM | CHRISM | | B= | C | 4764532 |
HAMMER HOMES, INC. | B= | P | 06/23/2014 | install address numbers on house -- Schedule a new Building Final when above items are complete. | CHRISM | CHRISM | | B= | P | 4763207 |
HAMMER HOMES, INC. | BLA | C | 03/24/2014 | | CHRISM | CHRISM | | BLA | C | 4707343 |
HAMMER HOMES, INC. | BIN | C | 03/11/2014 | | CHRISM | CHRISM | | BIN | C | 4700348 |
HAMMER HOMES, INC. | BFR | C | 03/11/2014 | | CHRISM | CHRISM | | BFR | C | 4700338 |
HAMMER HOMES, INC. | BFR | R | 03/05/2014 | ok to insulate, missing TBE6s at G01, bearing block HG01, H2,5 at H01, windbrace top of T02B, clean combustibles around fireplace flue and top of firebox | CHRISM | CHRISM | | BFR | R | 4697291 |
HAMMER HOMES, INC. | BFI | C | 10/30/2013 | R-10 at walkout walls | CHRISM | CHRISM | | BFI | C | 4632193 |
HAMMER HOMES, INC. | BFD | C | 10/30/2013 | soils on file drain usable isolate and float | CHRISM | CHRISM | | BFD | C | 4632190 |
HAMMER HOMES, INC. | BFN | C | 10/30/2013 | design and eng report on file | CHRISM | CHRISM | | BFN | C | 4632188 |
HAMMER HOMES, INC. | BFT | C | 10/30/2013 | eng report on file | CHRISM | CHRISM | | BFT | C | 4632185 |
HAMMER HOMES, INC. | BFN | P | 10/18/2013 | AUTHORIZED INSPECTION BY ENGINEER | REBECCA | REBECCA | REBECCA | BFN | P | 4625418 |
HAMMER HOMES, INC. | BFT | P | 10/18/2013 | AUTHORIZED INSPECTION BY ENGINEER | REBECCA | REBECCA | REBECCA | BFT | P | 4625417 |
FOUNTAIN VALLEY ELECTRICAL, LLC | E= | C | 06/11/2014 | 40 amp a/c ok need permit pulled for hot - tub | TOMC | TOMC | | E= | C | 4755992 |
FOUNTAIN VALLEY ELECTRICAL, LLC | E= | R | 06/04/2014 | canceled by builder, i only inspected lower exterior of house----- exposed wiring by garage man door, a/c not wired, missing screws at main disconnect | MATTHEW | MATTHEW | | E= | R | 4751540 |
FOUNTAIN VALLEY ELECTRICAL, LLC | ER | C | 02/27/2014 | ser feeder for hot tub pre-wire approved by dean---------------- ufer access at exterior by service disconnect | MATTHEW | MATTHEW | | ER | C | 4694343 |
FOUNTAIN VALLEY ELECTRICAL, LLC | ES | C | 02/27/2014 | Residential Overhead: 200 amp 3/w: new res--- meter is set; need seal | MATTHEW | MATTHEW | | ES | C | 4694341 |
FOUNTAIN VALLEY ELECTRICAL, LLC | ER | R | 02/25/2014 | can't feed hot tub out of sub-panel (fed with 4/0 al), ufer will need to be encased in concrete ------------ finished basement; --------------------------------- check panels and mcc's at time of service inspection------------------------------------ | MATTHEW | MATTHEW | | ER | R | 4692834 |
FOUNTAIN VALLEY ELECTRICAL, LLC | EUG | C | 12/19/2013 | service lateral from pole to house | MATTHEW | MATTHEW | | EUG | C | 4660466 |
MILLER HEATING & AIR CONDITIONING, INC. | H= | C | 06/12/2014 | All ok. | MARK | MARK | | H= | C | 4756708 |
MILLER HEATING & AIR CONDITIONING, INC. | H= | P | 06/10/2014 | 90 degree elbow at furnace exhaust pipe is not square to pipe. Needs to be replaced. Rest ok. | MARK | MARK | | H= | P | 4754586 |
MILLER HEATING & AIR CONDITIONING, INC. | H= | P | 06/06/2014 | Furnace vent exhaust side elbow in mech rm appears to be significantly misaligned. Need to seal line set and vent terminations at exterior wall. Rest ok. Note: Direct vent furnace and water heater, louver door 1 a/c, fin. Bsmnt. | MARK | MARK | | H= | P | 4752744 |
MILLER HEATING & AIR CONDITIONING, INC. | HC | C | 03/04/2014 | RELEASE METER | MICHAELS | MICHAELS | | HC | C | 4696876 |
MILLER HEATING & AIR CONDITIONING, INC. | HRR | C | 03/04/2014 | Corrections made. Note: duct design, FB, 6" osa, a/c rough(coil and lineset), direct vent furnace. | MICHAELS | MICHAELS | | HRR | C | 4696869 |
MILLER HEATING & AIR CONDITIONING, INC. | HRR | P | 02/27/2014 | It appears there is a return missing on lower level by bath in hall? Fresh air duct to upper level f/p is crushed (See at lower level f/p up toward upper level deck) No install instructions for f/p. Rest ok. Note: Direct vent furn, w/h. | MARK | MARK | | HRR | P | 4694348 |
MILLER HEATING & AIR CONDITIONING, INC. | HRR | R | 02/25/2014 | NO SAFETY RAILING INSTALLED NO INSPECTION | DAVIDH | DAVIDH | | HRR | R | 4693016 |
BLUE FLAME GAS COMPANY, INC. | HI | C | 02/13/2014 | correction made | TED | TED | | HI | C | 4686681 |
BLUE FLAME GAS COMPANY, INC. | HI | P | 02/12/2014 | LOW TEST NOTE 1 1/4" LINE 1 FURN,1 W/H,1 BBQ, AND C/T | DAVIDH | DAVIDH | | HI | P | 4685964 |
B & L PLUMBING, INC. | P= | C | 05/29/2014 | POTABLE WATER CERTIFICATE TO SCANNING | GABE | GABE | | P= | C | 4747312 |
B & L PLUMBING, INC. | PTO | C | 02/07/2014 | | JOEL | JOEL | | PTO | C | 4684271 |
B & L PLUMBING, INC. | PTO | R | 02/06/2014 | waive trip fee, still low test | JOEL | JOEL | | PTO | R | 4683934 |
B & L PLUMBING, INC. | PTO | P | 02/05/2014 | low test h2o, note:finished basement | JOEL | JOEL | | PTO | P | 4683381 |
HOMEOWNER | PWO | C | 11/20/2013 | | JOEL | JOEL | | PWO | C | 4645283 |
B & L PLUMBING, INC. | PB | C | 11/08/2013 | | JOEL | JOEL | | PB | C | 4638376 |