LAURIA BUILDERS & LAND, LLC. | B= | C | 07/17/2014 | trailer has been removed | DALE | DALE | | B= | C | 4778878 |
LAURIA BUILDERS & LAND, LLC. | B= | P | 04/16/2014 | Temp CO: need TCO to get them moved into house and out of mobile home so mobile home can ( Expires: 5/16/2014 12:00:00 AM) | MINDY | MINDY | | B= | P | 4721578 |
LAURIA BUILDERS & LAND, LLC. | B= | P | 04/08/2014 | Additional Inspections Required: External Agency Inspection F= by FIREDEPT is not Completed yet, External Agency Inspection HD= by HEALTHDEPT is not Completed yet. temp set mobile home needs to be removed from site, house ok -- Schedule a new Building Final when above items are complete. | CHRISM | CHRISM | | B= | P | 4716277 |
LAURIA BUILDERS & LAND, LLC. | BLA | C | 01/22/2014 | | CHRISM | CHRISM | | BLA | C | 4676090 |
LAURIA BUILDERS & LAND, LLC. | BIN | C | 01/14/2014 | | CHRISM | CHRISM | | BIN | C | 4671322 |
LAURIA BUILDERS & LAND, LLC. | BFR | C | 01/14/2014 | eng letter on file | CHRISM | CHRISM | | BFR | C | 4671321 |
LAURIA BUILDERS & LAND, LLC. | BIN | P | 01/10/2014 | insulation ok, waiting on truss fix | CHRISM | CHRISM | | BIN | P | 4670026 |
LAURIA BUILDERS & LAND, LLC. | BFR | R | 01/08/2014 | ok to insulate, need eng repair for A-6 truss | CHRISM | CHRISM | | BFR | R | 4668543 |
LAURIA BUILDERS & LAND, LLC. | BSP | P | 12/18/2013 | porch and posts ok | CHRISM | CHRISM | | BSP | P | 4659403 |
LAURIA BUILDERS & LAND, LLC. | BSP | R | 12/16/2013 | rear porch roof ok no post, front porch missing H2.5s and posts to beam connection | CHRISM | CHRISM | | BSP | R | 4657819 |
LAURIA BUILDERS & LAND, LLC. | BFN | C | 11/14/2013 | | CHRISM | CHRISM | | BFN | C | 4641316 |
LAURIA BUILDERS & LAND, LLC. | BFD | C | 11/14/2013 | eng letter on file for footer | CHRISM | CHRISM | | BFD | C | 4641315 |
LAURIA BUILDERS & LAND, LLC. | BFD | R | 11/12/2013 | not ready | CHRISM | CHRISM | | BFD | R | 4639210 |
LAURIA BUILDERS & LAND, LLC. | BFN | R | 11/12/2013 | design and eng report on file, footer at rear wall wont have 30" frost cover | CHRISM | CHRISM | | BFN | R | 4639209 |
LAURIA BUILDERS & LAND, LLC. | BFT | C | 11/12/2013 | eng report from Mybar on file | CHRISM | CHRISM | | BFT | C | 4639208 |
LAURIA BUILDERS & LAND, LLC. | BFN | P | 11/12/2013 | AUTHORIZED INSPECTION BY ENGINEER | TERRI | TERRI | TERRI | BFN | P | 4638990 |
LAURIA BUILDERS & LAND, LLC. | BFT | P | 11/12/2013 | AUTHORIZED INSPECTION BY ENGINEER | TERRI | TERRI | TERRI | BFT | P | 4638989 |
LONGHORN ELECTRIC, INC. | ES | C | 04/01/2014 | Residential Overhead: 200 amp 3/w: new res-------- no action needed | MATTHEW | MATTHEW | | ES | C | 4712800 |
LONGHORN ELECTRIC, INC. | E= | C | 04/01/2014 | dining room light replaces with keyless | MATTHEW | MATTHEW | | E= | C | 4712799 |
LONGHORN ELECTRIC, INC. | EP | C | 03/31/2014 | 200 amp sub-panel at home ok | MATTHEW | MATTHEW | | EP | C | 4712046 |
LONGHORN ELECTRIC, INC. | E= | R | 03/31/2014 | need approved breaker locks, 1.6kw micro on 30 amp breaker, ground dining room light, -------- light above bath not installed at time of final------------hot tub pre-wire-------no a/c | MATTHEW | MATTHEW | | E= | R | 4712045 |
LONGHORN ELECTRIC, INC. | EP | R | 01/06/2014 | NEED TO PHASE NEUTRAL------SEAL LB-----BOND TO GAS PIPE DUE TO THE FLEX------------- ok to see on final | BRIAN | BRIAN | | EP | R | 4667060 |
LONGHORN ELECTRIC, INC. | EUG | C | 01/06/2014 | FROM POLE TO HOUSE----- | BRIAN | BRIAN | | EUG | C | 4667059 |
LONGHORN ELECTRIC, INC. | ER | C | 01/02/2014 | 6-3 to cooktop and stubbed at back deck------------- finished basement | MATTHEW | MATTHEW | | ER | C | 4665656 |
ARROW HAWK HEATING, LLC | H= | C | 04/07/2014 | Note-- high/low transfer grills. | JEFFL | JEFFL | | H= | C | 4715531 |
MJB PLUMBING AND HEATING, INC | HI | C | 01/07/2014 | 11/4 furnace 2-water heaters 2-fireplaces bbq | TIM | TIM | | HI | C | 4667620 |
MJB PLUMBING AND HEATING, INC | HO | C | 01/07/2014 | | TIM | TIM | | HO | C | 4667619 |
ARROW HAWK HEATING, LLC | HC | C | 01/07/2014 | RELEASE METER | TIM | TIM | | HC | C | 4667617 |
ARROW HAWK HEATING, LLC | HRR | C | 01/07/2014 | has osa to r/a | TIM | TIM | | HRR | C | 4667615 |
ARROW HAWK HEATING, LLC | H16 | C | 01/06/2014 | Plan has note that outside air is to be installed. Water heaters do not need elevated if door is weather stripped and a thresh hold added with self closure and combustion air from outside. | JACK | JACK | | H16 | C | 4666904 |
ARROW HAWK HEATING, LLC | HRR | R | 01/02/2014 | outside air connected to the return is not on duct design plan, mechanical room access is from garage, need to raise water heaters 18'' above floor, need outside combustion air into mech. room for water heaters | TED | TED | | HRR | R | 4665683 |
MJB PLUMBING AND HEATING, INC | P= | C | 04/03/2014 | CORRECTIONS MADE | GABE | GABE | | P= | C | 4714111 |
MJB PLUMBING AND HEATING, INC | P= | P | 04/02/2014 | DISH WASHER NEEDS HI LOOP AT DRAIN , SECURE WATER PIPING TO WALL BEHIND WATER HEATER VENT . REST OK | GABE | GABE | | P= | P | 4713258 |
MJB PLUMBING AND HEATING, INC | PTO | C | 01/07/2014 | | TIM | TIM | | PTO | C | 4667618 |
HOMEOWNER | PWO | C | 11/20/2013 | | TIM | TIM | | PWO | C | 4645771 |
MJB PLUMBING AND HEATING, INC | PB | C | 11/19/2013 | | TIM | TIM | | PB | C | 4644783 |