HOMEOWNER | B= | C | 01/15/2015 | All other required Final inspections are complete. (This is a computer generated result) | BOBF | BOBF | | B= | C | 4885364 |
HOMEOWNER | B= | P | 01/15/2015 | Additional Inspections Required. | BOBF | BOBF | | B= | P | 4885254 |
HOMEOWNER | B= | R | 01/15/2015 | Additional Inspections Required: External Agency Inspection F= by FIREDEPT is not Completed yet, External Agency Inspection HD= by HEALTHDEPT is not Completed yet (This is a computer generated result) | SYSTEM | SYSTEM | | B= | R | 4885255 |
HOMEOWNER | B= | R | 01/14/2015 | Additional Inspections Required. seal outlet on exterior next to entry / provide ladder and remove attic access lid for attic insulation inspection | BOBF | BOBF | | B= | R | 4885076 |
HOMEOWNER | B= | R | 01/14/2015 | Additional Inspections Required: External Agency Inspection F= by FIREDEPT is not Completed yet, External Agency Inspection HD= by HEALTHDEPT is not Completed yet (This is a computer generated result) | SYSTEM | SYSTEM | | B= | R | 4885077 |
HOMEOWNER | BSP | P | 09/12/2014 | no inspection done/ reopen permit only | BLAKE | BLAKE | | BSP | P | 4814675 |
HOMEOWNER | BIN | C | 04/14/2014 | | JOHN | JOHN | | BIN | C | 4719807 |
HOMEOWNER | BFR | C | 04/10/2014 | | CHRISM | CHRISM | | BFR | C | 4718063 |
HOMEOWNER | BFR | R | 04/04/2014 | missing lateral braces A02, attic access | CHRISM | CHRISM | | BFR | R | 4714658 |
HOMEOWNER | BFN | P | 10/28/2013 | slab ok grade ok pending eng report | CHRISM | CHRISM | | BFN | P | 4630470 |
HOMEOWNER | BFI | C | 10/28/2013 | underslab insulation ok | CHRISM | CHRISM | | BFI | C | 4630468 |
HOMEOWNER | BFT | P | 10/28/2013 | ok to pour pending eng inspection, need stamped eng inspection letter and corrected design for file | CHRISM | CHRISM | | BFT | P | 4630465 |
HOMEOWNER | BFN | P | 10/23/2013 | AUTHORIZED INSPECTION BY ENGINEER | MINDY | MINDY | MINDY | BFN | P | 4627739 |
HOMEOWNER | BFT | P | 10/23/2013 | AUTHORIZED INSPECTION BY ENGINEER | MINDY | MINDY | MINDY | BFT | P | 4627738 |
HOMEOWNER | E= | C | 01/05/2015 | | MATTHEW | MATTHEW | | E= | C | 4880371 |
HOMEOWNER | ES | C | 12/12/2014 | Residential Underground: 100 amp 3/w: new res---- meter is set; need seal | MATTHEW | MATTHEW | | ES | C | 4871158 |
HOMEOWNER | E= | R | 12/12/2014 | outlet buried on kitchen countertop at penensula, afci protect dining room outlets and smokes, check for power at smoke in kitchen, install inter-system bond terminal, ground box and staple romex at pump switch, id white wire and verify pump switch is a 2 pole not a 4 way, gfci behind fridge needs to be accessible----------- no a/c | MATTHEW | MATTHEW | | E= | R | 4871157 |
HOMEOWNER | ER | C | 03/25/2014 | #6nm to range | MATTHEW | MATTHEW | | ER | C | 4708250 |
HOMEOWNER | ES | R | 03/25/2014 | remove equipment ground from service lateral, attach sub-panel ground to service disconnect, remove temp and land in pedestal | MATTHEW | MATTHEW | | ES | R | 4708237 |
HOMEOWNER | ES | R | 03/18/2014 | need service disconnect exterior of house; check sub-panel------------------- homeowner is using existing service lateral--------------- need to leave underground splices open for inspection | MATTHEW | MATTHEW | | ES | R | 4704365 |
HOMEOWNER | ER | R | 03/18/2014 | need neutral at switches, add outlet 1/2 wall and dining room needs to be on small appliance circuit, remove back exterior outlet from small appliance circuit---------------- sheetrock stacked against walls------------------------------------------ address is at the end of gladys st------------------------- | MATTHEW | MATTHEW | | ER | R | 4704362 |
HOMEOWNER | H= | C | 12/22/2014 | Clearance issue resolved. Ok. | MARK | MARK | | H= | C | 4875968 |
HOMEOWNER | H= | P | 12/12/2014 | Need clearance to drywall at b vent. Rest ok. Note: Louver door. | MARK | MARK | | H= | P | 4870506 |
HOMEOWNER | HC | C | 03/18/2014 | RELEASE METER | TED | TED | | HC | C | 4704646 |
HOMEOWNER | HI | C | 03/18/2014 | 3/4'' 2- water heaters | TED | TED | | HI | C | 4704638 |
HOMEOWNER | HRR | C | 03/18/2014 | water heater vents connected to common vent, note: check water heater being used for in floor heating, need backflow, reg. and a rated t&p for system requirement | TED | TED | | HRR | C | 4704633 |
ARROW HAWK HEATING, LLC | HRR | P | 02/14/2014 | 2-water heater venting, 2-bath fan vents, dryer vent | TED | TED | | HRR | P | 4687471 |
HOMEOWNER | HO | C | 12/20/2013 | 10 LB TEST OK | DAVIDH | DAVIDH | | HO | C | 4660997 |
HOMEOWNER | HWP | P | 10/29/2013 | 55 LB TEST OK NOTE OK TO POUR | DAVIDH | DAVIDH | | HWP | P | 4631640 |
HOMEOWNER | P= | C | 01/13/2015 | POTABLE WATER CERT TO SCANNING . | GABE | GABE | | P= | C | 4884233 |
HOMEOWNER | P= | P | 12/12/2014 | NEED POTABLE WATER CERT TO COMPLETE . REST OK . NOTE , SLAB . NO IRRIGATION | GABE | GABE | | P= | P | 4870641 |
HOMEOWNER | PTO | C | 03/31/2014 | corrections made . | GABE | GABE | | PTO | C | 4711450 |
HOMEOWNER | PTO | R | 03/25/2014 | washer box trap to close to outside wall for insulation, rest ok, slab on grade | TED | TED | | PTO | R | 4708654 |
HOMEOWNER | PTO | R | 03/19/2014 | locked | TIM | TIM | | PTO | R | 4704817 |
HOMEOWNER | PWO | P | 10/28/2013 | HAVE EXISTING WELL HEAD AND WELL PIPING -- DO QUESTION APPROVAL TO HAVE OLD BLACK POLY UNDER NEW FOOTER ?? | LEE | LEE | | PWO | P | 4630549 |
HOMEOWNER | PB | C | 10/24/2013 | access off GLADYS st. | TED | TED | | PB | C | 4628988 |