HOMEOWNER | B= | C | 05/31/2016 | All other required Final inspections are complete. (This is a computer generated result) | BOBF | BOBF | | B= | C | 5211272 |
HOMEOWNER | B= | P | 10/05/2015 | building okay pending Health and Black forest fire finals. Additional Inspections Required (computer generated): External Agency Inspection F= by FIREDEPT is not Completed yet, External Agency Inspection HD= by HEALTHDEPT is not Completed yet. | BOBF | BOBF | | B= | P | 5050884 |
HOMEOWNER | BSP | P | 06/09/2015 | extend permit | ED | ED | | BSP | P | 4969292 |
HOMEOWNER | BSP | P | 03/25/2015 | PLAN SPLICE: (No Fee) by: SHELLEY for Construction: revised foundation plan and thermal envelope clarification | SHELLEY | SHELLEY | | BSP | P | 4923197 |
HOMEOWNER | B= | P | 03/19/2015 | unheated basement - floor joist cavities will need to be insulated, secure egress ladder, add center stringer to stairs, return handrail to wall, install gutters / downspouts chief custom homes, unit ID # 14-M 32504 date built 9/16/13 crt # 35093 -- Schedule a new Building Final when above items are complete. Additional Inspections Required (computer generated): External Agency Inspection F= by FIREDEPT is not Completed yet, External Agency Inspection HD= by HEALTHDEPT is not Completed yet. | ED | ED | | B= | P | 4920405 |
HOMEOWNER | BTD | C | 12/19/2013 | connections at marriage wall ok, need to support cut beam in basement | CHRISM | CHRISM | | BTD | C | 4660326 |
HOMEOWNER | BFD | C | 11/01/2013 | soils on file drain entire isolate and float | CHRISM | CHRISM | | BFD | C | 4634249 |
HOMEOWNER | BFN | C | 10/28/2013 | all paperwork at drain | CHRISM | CHRISM | | BFN | C | 4630411 |
HOMEOWNER | BFT | C | 10/24/2013 | 1500# bearing pads ok | CHRISM | CHRISM | | BFT | C | 4628672 |
JACK'S ELECTRICAL & MAINTENANCE | E= | C | 05/23/2014 | | MATTHEW | MATTHEW | | E= | C | 4744928 |
JACK'S ELECTRICAL & MAINTENANCE | E= | R | 05/19/2014 | gfci test needs to be in a readily accessible location, remove neutral from ground bar in well disconnect and cap off | MATTHEW | MATTHEW | | E= | R | 4741243 |
JACK'S ELECTRICAL & MAINTENANCE | ES | C | 05/19/2014 | Residential Overhead: 200 amp 3/w: new res------------ meter is set; need seal | MATTHEW | MATTHEW | | ES | C | 4741242 |
JACK'S ELECTRICAL & MAINTENANCE | E= | R | 05/07/2014 | job is for modular home service, call me in the am to transfer permit | MATTHEW | MATTHEW | | E= | R | 4734937 |
JACK'S ELECTRICAL & MAINTENANCE | EST | R | 05/07/2014 | need neutral in lug in panel, install equipment ground to well disconnect, need seimens breaker for well, need gfci protection for sump, need light and outlet in basement---------------- call me in the am to transfer permit to modular | MATTHEW | MATTHEW | | EST | R | 4734936 |
HOMEOWNER | H= | C | 10/01/2015 | Alert on address for unheated basement. | JACK | JACK | | H= | C | 5048617 |
HOMEOWNER | HC | C | 11/10/2014 | RELEASE METER | TIM | TIM | | HC | C | 4851329 |
HOMEOWNER | HRR | C | 11/10/2014 | | TIM | TIM | | HRR | C | 4851326 |
HOMEOWNER | H= | P | 11/10/2014 | unfinished basement no a/c electric wtr htr, 3-23-15 Jon B added note and changed to partial to address unheated basement issues. | TIM | TIM | | H= | P | 4851322 |
O.M.A.G.M., INC. | HI | C | 11/03/2014 | 10 lb test from ext wall to furnace is ok. Furnace is set up for propane. | MARK | MARK | | HI | C | 4846883 |
O.M.A.G.M., INC. | HO | C | 11/08/2013 | 10 LB TEST OK NOTE OK TO COVER | DAVIDH | DAVIDH | | HO | C | 4638143 |
HOMEOWNER | P= | C | 11/20/2014 | received potable water cert | TIM | TIM | | P= | C | 4856975 |
HOMEOWNER | PTO | C | 11/10/2014 | | TIM | TIM | | PTO | C | 4851321 |
HOMEOWNER | P= | P | 11/10/2014 | need proof of potable water | TIM | TIM | | P= | P | 4851314 |
HOMEOWNER | PWO | C | 01/03/2014 | | TIM | TIM | | PWO | C | 4666271 |