CLIFFORD JOYNER CONSTRUCTION COMPANY, INC. | B= | C | 06/13/2014 | All other required Final inspections are complete. (This is a computer generated result) | CHRISM | CHRISM | | B= | C | 4757259 |
CLIFFORD JOYNER CONSTRUCTION COMPANY, INC. | B= | P | 04/22/2014 | Additional Inspections Required: External Agency Inspection F= by FIREDEPT is not Completed yet. unfinished basement | CHRISM | CHRISM | | B= | P | 4724856 |
CLIFFORD JOYNER CONSTRUCTION COMPANY, INC. | BIN | C | 02/05/2014 | | CHRISM | CHRISM | | BIN | C | 4683253 |
CLIFFORD JOYNER CONSTRUCTION COMPANY, INC. | BFR | C | 02/05/2014 | | CHRISM | CHRISM | | BFR | C | 4683252 |
CLIFFORD JOYNER CONSTRUCTION COMPANY, INC. | BFR | R | 01/31/2014 | ok to insulate, missing H2.5s at D trusses | CHRISM | CHRISM | | BFR | R | 4681423 |
CLIFFORD JOYNER CONSTRUCTION COMPANY, INC. | BLA | C | 01/28/2014 | | CHRISM | CHRISM | | BLA | C | 4678578 |
CLIFFORD JOYNER CONSTRUCTION COMPANY, INC. | BSP | P | 01/27/2014 | front porch roof and deck ok, need post to beam connections by final | CHRISM | CHRISM | | BSP | P | 4678014 |
CLIFFORD JOYNER CONSTRUCTION COMPANY, INC. | BSP | P | 12/17/2013 | deck piers ok | CHRISM | CHRISM | | BSP | P | 4658530 |
CLIFFORD JOYNER CONSTRUCTION COMPANY, INC. | BSP | T | 12/11/2013 | PAID (REC#1170517) ADDITIONAL PLAN REVIEW TIME: $50 From: DANM Adding chase for wood burning stove | DANM | DANM | | BSP | T | 4655411 |
CLIFFORD JOYNER CONSTRUCTION COMPANY, INC. | BFI | C | 11/20/2013 | R-10 at walkout walls | CHRISM | CHRISM | | BFI | C | 4645347 |
CLIFFORD JOYNER CONSTRUCTION COMPANY, INC. | BFD | C | 11/20/2013 | | CHRISM | CHRISM | | BFD | C | 4645345 |
CLIFFORD JOYNER CONSTRUCTION COMPANY, INC. | BFN | C | 11/14/2013 | design and soils on file drain usable isolate and float | CHRISM | CHRISM | | BFN | C | 4641784 |
CLIFFORD JOYNER CONSTRUCTION COMPANY, INC. | BFT | C | 11/07/2013 | 2400# bearing pads ok | CHRISM | CHRISM | | BFT | C | 4637517 |
SLAVENS ELECTRIC | E= | C | 04/14/2014 | no a/c | MATTHEW | MATTHEW | | E= | C | 4719768 |
SLAVENS ELECTRIC | E= | R | 04/08/2014 | protect nm over top (in between the studs) | MATTHEW | MATTHEW | | E= | R | 4716439 |
SLAVENS ELECTRIC | E= | R | 04/04/2014 | install inter-system bond terminal, protect nm at basement light switches, gfci for water heater blower not accessible, closet light too close to shelf, afci stairs---------- no a/c-------- | MATTHEW | MATTHEW | | E= | R | 4715035 |
SLAVENS ELECTRIC | ES | C | 04/04/2014 | Residential Overhead: 150 amp 3/w: new res------meter is set; need seal | MATTHEW | MATTHEW | | ES | C | 4715034 |
SLAVENS ELECTRIC | ES | R | 01/27/2014 | Remove temp service at utility pole and install PVC schedule 80 riser into meter housing. Terminate conductors, See comments for rough also | JOSEPH | JOSEPH | | ES | R | 4678276 |
SLAVENS ELECTRIC | EP | R | 01/27/2014 | Verify ufer connection should be where ser enters building. Unable to read conductor size on ser cable to sub panel, conductors look too small for 150 amp sub. They should be 2/0. --------- | JOSEPH | JOSEPH | | EP | R | 4678423 |
SLAVENS ELECTRIC | ER | C | 01/27/2014 | | JOSEPH | JOSEPH | | ER | C | 4678275 |
SLAVENS ELECTRIC | EUG | C | 12/26/2013 | 12-2 and 12-3 uf from house to well pit | MATTHEW | MATTHEW | | EUG | C | 4662871 |
SLAVENS ELECTRIC | EUG | P | 12/04/2013 | per contractor: panel on pole is to be removed---- verify at time of service inspection | MATTHEW | MATTHEW | | EUG | P | 4652317 |
EAGLE HEATING AND AIR CONDITIONING, INC. | H= | C | 04/21/2014 | Mantel clearance ok. | JEFFL | JEFFL | | H= | C | 4724042 |
EAGLE HEATING AND AIR CONDITIONING, INC. | HC | C | 01/30/2014 | RELEASE METER | DAVIDH | DAVIDH | | HC | C | 4680595 |
EAGLE HEATING AND AIR CONDITIONING, INC. | HRR | C | 01/30/2014 | OK NOTE EQUIP CHECK OK UNFINISHED BASEMENT | DAVIDH | DAVIDH | | HRR | C | 4680594 |
EAGLE HEATING AND AIR CONDITIONING, INC. | HRR | R | 01/29/2014 | NO DESIGN PLANS ON SITE OR EQUIP LIST ALSO FIREPLACE NOT FRAMED | DAVIDH | DAVIDH | | HRR | R | 4679915 |
BROOKS PLUMBING & HEATING INC. | HI | C | 01/28/2014 | 10 LB TEST OK NOTE 1" LINE 1 FURN,1 F/P,W/H AND C/T | DAVIDH | DAVIDH | | HI | C | 4678665 |
BROOKS PLUMBING & HEATING INC. | HO | C | 12/26/2013 | 1 1/4'' p.e. under ground from meter location at street to house | TED | TED | | HO | C | 4662740 |
BROOKS PLUMBING & HEATING INC. | P= | C | 04/21/2014 | UNFINISHED BSAEMENT | GABE | GABE | | P= | C | 4723676 |
BROOKS PLUMBING & HEATING INC. | PTO | C | 01/16/2014 | | JOEL | JOEL | | PTO | C | 4673011 |
BROOKS PLUMBING & HEATING INC. | PB | C | 12/03/2013 | | JOEL | JOEL | | PB | C | 4651552 |
HOMEOWNER | PWO | C | 12/02/2013 | | JOEL | JOEL | | PWO | C | 4650017 |