SC SCOTT CONSTRUCTION CONSULTING, L.L.C. | B= | C | 07/01/2014 | | JOHN | JOHN | | B= | C | 4769090 |
SC SCOTT CONSTRUCTION CONSULTING, L.L.C. | BSP | P | 05/27/2014 | deck and columns ok | CHRISM | CHRISM | | BSP | P | 4745704 |
SC SCOTT CONSTRUCTION CONSULTING, L.L.C. | BLA | C | 03/21/2014 | | DANF | DANF | | BLA | C | 4706572 |
SC SCOTT CONSTRUCTION CONSULTING, L.L.C. | BIN | C | 03/05/2014 | | CHRISM | CHRISM | | BIN | C | 4697234 |
SC SCOTT CONSTRUCTION CONSULTING, L.L.C. | BFR | C | 03/05/2014 | eng letter on file | CHRISM | CHRISM | | BFR | C | 4697233 |
SC SCOTT CONSTRUCTION CONSULTING, L.L.C. | BFR | R | 02/27/2014 | ok to insulate, truss eng to check damage to gussets on FG girder | CHRISM | CHRISM | | BFR | R | 4694117 |
SC SCOTT CONSTRUCTION CONSULTING, L.L.C. | BIN | P | 02/26/2014 | Qualified third party energy inspection documentation must be presented at time of final building (B=) inspection | INTERNET | INTERNET | | BIN | P | 4693779 |
SC SCOTT CONSTRUCTION CONSULTING, L.L.C. | BSP | P | 02/25/2014 | front porch columns ok | CHRISM | CHRISM | | BSP | P | 4692558 |
SC SCOTT CONSTRUCTION CONSULTING, L.L.C. | BSP | P | 02/10/2014 | rear porch roof and posts ok, front porch roof ok no posts | CHRISM | CHRISM | | BSP | P | 4684707 |
SC SCOTT CONSTRUCTION CONSULTING, L.L.C. | BSP | P | 12/17/2013 | deck piers ok | CHRISM | CHRISM | | BSP | P | 4658497 |
SC SCOTT CONSTRUCTION CONSULTING, L.L.C. | BFI | C | 12/03/2013 | R-10 at walkout walls | CHRISM | CHRISM | | BFI | C | 4651585 |
SC SCOTT CONSTRUCTION CONSULTING, L.L.C. | BFD | C | 12/03/2013 | soils on file drain usable isolate and float | CHRISM | CHRISM | | BFD | C | 4651529 |
SC SCOTT CONSTRUCTION CONSULTING, L.L.C. | BFN | C | 11/20/2013 | design and soils on file, stamped open hole at drain | CHRISM | CHRISM | | BFN | C | 4645329 |
SC SCOTT CONSTRUCTION CONSULTING, L.L.C. | BFT | C | 11/12/2013 | 3000# bearing pads ok | CHRISM | CHRISM | | BFT | C | 4639499 |
FIRST RATE ELECTRICAL SERVICES, INC. | E= | C | 06/23/2014 | 40 AMP AC OK | BRIAN | BRIAN | | E= | C | 4763586 |
FIRST RATE ELECTRICAL SERVICES, INC. | ER | C | 02/26/2014 | hot tub wiring removed---------------------- non-ic remodel can at display box in basement is up against 2x4's need to correct and i'll check at final | MATTHEW | MATTHEW | | ER | C | 4693683 |
FIRST RATE ELECTRICAL SERVICES, INC. | ES | C | 02/25/2014 | Residential Underground: 200 amp 3/w: new res----------- meter is set---- need seal | MATTHEW | MATTHEW | | ES | C | 4692793 |
FIRST RATE ELECTRICAL SERVICES, INC. | ER | R | 02/25/2014 | add outlet at handrail, hot tub can't be fed from sub-panel (fed with #2al ser), sub-panel feeder needs to be derated (in insulation at exterior wall)----------------- finished basement---- sub-panel make up ok (not breakered), 4-15 at sub-panel, 1-20 at service | MATTHEW | MATTHEW | | ER | R | 4692788 |
FIRST RATE ELECTRICAL SERVICES, INC. | EUG | C | 12/17/2013 | from meter ped to house--- | BRIAN | BRIAN | | EUG | C | 4658604 |
REGIONAL HEATING AND AIR CONDITIONING, INC. | H= | C | 06/25/2014 | finished basement, a/c installed, louver door | TED | TED | | H= | C | 4765169 |
REGIONAL HEATING AND AIR CONDITIONING, INC. | HC | C | 02/25/2014 | RELEASE METER | DAVIDH | DAVIDH | | HC | C | 4693003 |
REGIONAL HEATING AND AIR CONDITIONING, INC. | HRR | C | 02/25/2014 | OK NOTE FINISHED BASEMENT, EQUIP CHECK OK . 6" OSA | DAVIDH | DAVIDH | | HRR | C | 4693001 |
HOLMES PLUMBING & HEATING INC | HI | C | 02/21/2014 | 10# test ok. 1 1/2" main to furn, 2-w/h, 2-fp, c-top, free-standing fp, bbq, future fire pit. | MICHAELS | MICHAELS | | HI | C | 4691307 |
HOLMES PLUMBING & HEATING INC | P= | C | 06/24/2014 | NOTE ; finished basement . NO IRRIGATION . POTABLE WATER CERT TO SCANNING | GABE | GABE | | P= | C | 4764234 |
HOLMES PLUMBING & HEATING INC | PTO | C | 02/24/2014 | correction made. | DICK | DICK | | PTO | C | 4692047 |
HOLMES PLUMBING & HEATING INC | PTO | P | 02/21/2014 | low test dwv, 3'' to master lacks proper grade | JOEL | JOEL | | PTO | P | 4691025 |
HOLMES PLUMBING & HEATING INC | PWO | C | 02/20/2014 | | JOEL | JOEL | | PWO | C | 4690191 |
HOLMES PLUMBING & HEATING INC | PWO | R | 02/19/2014 | | TED | TED | | PWO | R | 4689440 |
HOLMES PLUMBING & HEATING INC | PWO | R | 02/14/2014 | h20 covered up | JOEL | JOEL | | PWO | R | 4687648 |
HOLMES PLUMBING & HEATING INC | PB | C | 12/16/2013 | | TIM | TIM | | PB | C | 4657830 |