TOTAL SOLUTIONS PROVIDER CO. | B= | C | 06/13/2014 | All other required Final inspections are complete. (This is a computer generated result) | CHRISM | CHRISM | | B= | C | 4758085 |
TOTAL SOLUTIONS PROVIDER CO. | B= | P | 06/05/2014 | Additional Inspections Required: External Agency Inspection HD= by HEALTHDEPT is not Completed yet, Electrical Final Inspection is not Completed yet. | CHRISM | CHRISM | | B= | P | 4751998 |
TOTAL SOLUTIONS PROVIDER CO. | BLA | C | 03/21/2014 | | NICK | NICK | | BLA | C | 4706507 |
TOTAL SOLUTIONS PROVIDER CO. | BLA | R | 03/20/2014 | need extension rings on all electric boxes | CHRISM | CHRISM | | BLA | R | 4705828 |
TOTAL SOLUTIONS PROVIDER CO. | BIN | C | 03/06/2014 | SIPs panel | CHRISM | CHRISM | | BIN | C | 4698146 |
TOTAL SOLUTIONS PROVIDER CO. | BFR | C | 03/06/2014 | | CHRISM | CHRISM | | BFR | C | 4698142 |
TOTAL SOLUTIONS PROVIDER CO. | BIN | P | 03/05/2014 | Qualified third party energy inspection documentation must be presented at time of final building (B=) inspection | INTERNET | INTERNET | | BIN | P | 4697552 |
TOTAL SOLUTIONS PROVIDER CO. | BFN | C | 12/05/2013 | design and eng report on file | CHRISM | CHRISM | | BFN | C | 4653134 |
TOTAL SOLUTIONS PROVIDER CO. | BFD | C | 12/05/2013 | soils on file no drain required | CHRISM | CHRISM | | BFD | C | 4653132 |
TOTAL SOLUTIONS PROVIDER CO. | BFT | C | 12/05/2013 | eng report on file | CHRISM | CHRISM | | BFT | C | 4653130 |
TOTAL SOLUTIONS PROVIDER CO. | BFD | P | 12/02/2013 | drain exterior crawl ok, need all paperwork | CHRISM | CHRISM | | BFD | P | 4649875 |
TOTAL SOLUTIONS PROVIDER CO. | BFN | P | 11/19/2013 | AUTHORIZED INSPECTION BY ENGINEER | NELIDA | NELIDA | NELIDA | BFN | P | 4644278 |
TOTAL SOLUTIONS PROVIDER CO. | BFT | P | 11/19/2013 | AUTHORIZED INSPECTION BY ENGINEER | NELIDA | NELIDA | NELIDA | BFT | P | 4644277 |
JLC ELECTRIC LLC | E= | C | 06/13/2014 | 25 amp a/c and hot tub installed | MATTHEW | MATTHEW | | E= | C | 4758084 |
JLC ELECTRIC LLC | E= | R | 06/11/2014 | correct outlet spacing at kitchen countertop, label panel correctly, bond for hot tub needs to be rated for wet location (brass lug and stainless bolt and nut; can't use screws for grounding) --------------------outlet under wet bar has been removed | MATTHEW | MATTHEW | | E= | R | 4756256 |
JLC ELECTRIC LLC | E= | R | 06/09/2014 | label panel, correct kitchen countertop and master bedroom outlet spacing, correct closet light spacing, remove lights within 5' of tub, bond all metal within 5' of hot tub, guard crawler lights, bond well disconnect, phase well wire, pull correct color wire in crawler j-box (#10 re-phased), gfci all outlets within 6' of utility sink, 25 amp a/c ok-------------- verify second permit is pulled for detached garage before finaling house permit | MATTHEW | MATTHEW | | E= | R | 4754114 |
JLC ELECTRIC LLC | ES | C | 06/09/2014 | Residential Overhead: 200 amp 3/w: new res---- meter is set; need seal | MATTHEW | MATTHEW | | ES | C | 4754101 |
JLC ELECTRIC LLC | E= | R | 06/03/2014 | complete re-inspect-------- lights not working, open tub and correct lighting around tub,, exterior outlets not wr, phase grounds green and white wires as phase conductors where needed, need to see fan rated boxes where wiremold is used, need tr outlets, need gfci protection 6' from sink----------- I did not finish inspection | MATTHEW | MATTHEW | | E= | R | 4750213 |
JLC ELECTRIC LLC | ES | R | 06/03/2014 | need #4 grounding electrode conductor, missing panel screws, I can't tell which neutral goes with what phase conductor------ panel wiring and labeling need to be cleaned up | MATTHEW | MATTHEW | | ES | R | 4750207 |
JLC ELECTRIC LLC | ER | C | 03/05/2014 | need to check crawler on final--- | BRIAN | BRIAN | | ER | C | 4697189 |
JLC ELECTRIC LLC | EUG | C | 02/13/2014 | | MATTHEW | MATTHEW | | EUG | C | 4686990 |
PREMIER MECHANICAL | H= | C | 05/20/2014 | NOTE : RETURN IN MASTER CLOSET | GABE | GABE | | H= | C | 4741872 |
PREMIER MECHANICAL | HC | C | 02/19/2014 | RELEASE METER | TED | TED | | HC | C | 4689570 |
PREMIER MECHANICAL | HI | C | 02/19/2014 | 1'' furnace, w/h, fireplace, range | TED | TED | | HI | C | 4689569 |
PREMIER MECHANICAL | HRR | C | 02/19/2014 | at final check return in master bedroom closet, note: conditioned crawlspace, a/c rough, duct design, outside air to return | TED | TED | | HRR | C | 4689553 |
CASCADE PLUMBING & HEATING | P= | C | 05/20/2014 | NOTE : NO IRRIGATION . POTABLE WATER CERTIFICATE TO SCANNING | GABE | GABE | | P= | C | 4741873 |
CASCADE PLUMBING & HEATING | PB | C | 02/28/2014 | | DICK | DICK | | PB | C | 4695400 |
CASCADE PLUMBING & HEATING | PWO | C | 02/24/2014 | certificate of potable water by final. | DICK | DICK | | PWO | C | 4692102 |
CASCADE PLUMBING & HEATING | PB | P | 02/19/2014 | can not run s&d under footer into crawlspace, need sch 40 run 3 feet to outside | TED | TED | | PB | P | 4689558 |
CASCADE PLUMBING & HEATING | PTO | C | 02/19/2014 | conditioned crawlspace | TED | TED | | PTO | C | 4689554 |