CLANCY BUILDING & DESIGN, LLC | B= | C | 06/19/2014 | All other required Final inspections are complete. (This is a computer generated result) | CHRISM | CHRISM | | B= | C | 4761533 |
CLANCY BUILDING & DESIGN, LLC | B= | P | 06/09/2014 | Additional Inspections Required: External Agency Inspection F= by FIREDEPT is not Completed yet, External Agency Inspection HD= by HEALTHDEPT is not Completed yet. finished basement | CHRISM | CHRISM | | B= | P | 4753854 |
CLANCY BUILDING & DESIGN, LLC | BSP | P | 05/13/2014 | front porch columns ok | CHRISM | CHRISM | | BSP | P | 4737572 |
CLANCY BUILDING & DESIGN, LLC | BIN | C | 04/08/2014 | finished basement | CHRISM | CHRISM | | BIN | C | 4716171 |
CLANCY BUILDING & DESIGN, LLC | BFR | C | 04/08/2014 | | CHRISM | CHRISM | | BFR | C | 4716170 |
CLANCY BUILDING & DESIGN, LLC | BFR | R | 04/01/2014 | ok to insulate, block oh door brackets, hanger joists at landing, steel shim beam | CHRISM | CHRISM | | BFR | R | 4712643 |
CLANCY BUILDING & DESIGN, LLC | BLA | C | 03/18/2014 | | CHRISM | CHRISM | | BLA | C | 4704263 |
CLANCY BUILDING & DESIGN, LLC | BTR | C | 03/14/2014 | | CHRISM | CHRISM | | BTR | C | 4702802 |
CLANCY BUILDING & DESIGN, LLC | BTR | P | 02/28/2014 | no penetrations out of roof at this time | CHRISM | CHRISM | | BTR | P | 4695082 |
CLANCY BUILDING & DESIGN, LLC | BFI | C | 12/17/2013 | R-10 at walkout | CHRISM | CHRISM | | BFI | C | 4658515 |
CLANCY BUILDING & DESIGN, LLC | BFD | C | 12/16/2013 | soils on file drain usable isolate and float | CHRISM | CHRISM | | BFD | C | 4657686 |
CLANCY BUILDING & DESIGN, LLC | BFN | C | 12/16/2013 | eng report on file | CHRISM | CHRISM | | BFN | C | 4657685 |
CLANCY BUILDING & DESIGN, LLC | BFT | C | 12/16/2013 | eng report on file | CHRISM | CHRISM | | BFT | C | 4657684 |
CLANCY BUILDING & DESIGN, LLC | BFN | P | 12/13/2013 | AUTHORIZED INSPECTION BY ENGINEER | JANE | JANE | JANE | BFN | P | 4656632 |
CLANCY BUILDING & DESIGN, LLC | BFT | P | 12/13/2013 | AUTHORIZED INSPECTION BY ENGINEER | JANE | JANE | JANE | BFT | P | 4656631 |
SANCHEZ ELECTRIC, INC. | E= | C | 05/27/2014 | no a/c | TOMC | TOMC | | E= | C | 4746040 |
SANCHEZ ELECTRIC, INC. | EUG | C | 04/14/2014 | service lateral from pole to house | MATTHEW | MATTHEW | | EUG | C | 4719760 |
SANCHEZ ELECTRIC, INC. | ES | C | 04/14/2014 | Residential Overhead: 200 amp 3/w: new res---- meter is set; need seal | MATTHEW | MATTHEW | | ES | C | 4719759 |
SANCHEZ ELECTRIC, INC. | ER | C | 03/31/2014 | no mcc 2 - 10/3 to well / dryer 4/w 1/0 al to sub finished basement | CRAIG | CRAIG | | ER | C | 4711984 |
AIR CONCEPTS HEATING & COOLING | H= | C | 06/05/2014 | duct leakage report to scanning | TED | TED | | H= | C | 4751995 |
AIR CONCEPTS HEATING & COOLING | H= | R | 06/04/2014 | need duct leakage report, complete furnace vent outlet, note: finished basement, no a/c | TED | TED | | H= | R | 4751199 |
AIR CONCEPTS HEATING & COOLING | HC | C | 03/28/2014 | RELEASE METER | JEFFL | JEFFL | | HC | C | 4711011 |
AIR CONCEPTS HEATING & COOLING | HRR | C | 03/28/2014 | Notes-- check furnace vent connection in mech room at final. Duct leakage report for attic system by final.. Finished basement.. OSA to return. Duct design. | JEFFL | JEFFL | | HRR | C | 4711010 |
DAVIS GAS SHOP INC | HI | C | 03/24/2014 | 10 LB. pressure test ok Notes-- medium pressure.. 1'' main.. 2 furnace.. 1 water heater.. 1 range..3 fp ***2 lb. letter needed by final. Lines to be tagged "medium pressure" every six ft. where visible. | JEFFL | JEFFL | | HI | C | 4707158 |
CHEYENNE PLUMBING & HEATING, INC. | P= | C | 06/09/2014 | received potable water cert | TIM | TIM | | P= | C | 4753538 |
CHEYENNE PLUMBING & HEATING, INC. | P= | P | 06/04/2014 | need proof of potable water...rest ok | TIM | TIM | | P= | P | 4751389 |
CHEYENNE PLUMBING & HEATING, INC. | PTO | C | 03/27/2014 | | TIM | TIM | | PTO | C | 4709936 |
CHEYENNE PLUMBING & HEATING, INC. | PB | C | 02/26/2014 | | DICK | DICK | | PB | C | 4693662 |
CHEYENNE PLUMBING & HEATING, INC. | PB | P | 02/25/2014 | low test garage. basement ok. ejector pit. | DICK | DICK | | PB | P | 4692750 |
HOMEOWNER | PWO | C | 12/30/2013 | | JOEL | JOEL | | PWO | C | 4664177 |