ALLURE HOMES LTD | B= | C | 08/18/2014 | front porch on seperate permit | DALE | DALE | | B= | C | 4798696 |
ALLURE HOMES LTD | BSP | P | 08/15/2014 | Front porch on separate permit. | ROGER | ROGER | | BSP | P | 4797940 |
ALLURE HOMES LTD | B= | P | 08/01/2014 | Temp CO: Owner Request ( Expires: 8/31/2014 12:00:00 AM) | ROGER | ROGER | | B= | P | 4788833 |
ALLURE HOMES LTD | B= | P | 07/31/2014 | Additional Inspections Required: Electrical Final Inspection is not Completed yet, Plumbing Final Inspection is not Completed yet. complete front porch / install gutters and perminant house # / finished basement, deck in -- Schedule a new Building Final when above items are complete. | DALE | DALE | | B= | P | 4787619 |
ALLURE HOMES LTD | BSP | P | 07/23/2014 | Deck frame OK | NICK | NICK | | BSP | P | 4782257 |
ALLURE HOMES LTD | BSP | R | 07/22/2014 | need plans | DALE | DALE | | BSP | R | 4781635 |
ALLURE HOMES LTD | BLA | C | 06/06/2014 | | CHRISM | CHRISM | | BLA | C | 4752962 |
ALLURE HOMES LTD | BSP | P | 06/02/2014 | rear porch roof ok, no posts | CHRISM | CHRISM | | BSP | P | 4749193 |
ALLURE HOMES LTD | BIN | C | 05/08/2014 | | CHRISM | CHRISM | | BIN | C | 4735074 |
ALLURE HOMES LTD | BFR | P | 05/08/2014 | inside ok, porch roofs not complete | CHRISM | CHRISM | | BFR | P | 4735065 |
ALLURE HOMES LTD | BFR | P | 05/05/2014 | add lateral bracing at S4 thru S12 trusses, S16 truss hardware missing nails, , engineered stamped interior bearing log posts ok, frame out 24" o.c under stairs, add point load under 2 ply LVL ok to insulate | ED | ED | | BFR | P | 4733124 |
ALLURE HOMES LTD | BSP | T | 04/30/2014 | PAID (REC#1192193) ADDITIONAL PLAN REVIEW TIME: $50 From: JIMA splice : added deck and changed post / see cloud change | JIMA | JIMA | | BSP | T | 4729909 |
ALLURE HOMES LTD | BIN | C | 11/27/2013 | R-10 at walkout walls | CHRISM | CHRISM | | BIN | C | 4648885 |
ALLURE HOMES LTD | BFD | C | 11/22/2013 | soils on file drain usable isolate and float | CHRISM | CHRISM | | BFD | C | 4646822 |
ALLURE HOMES LTD | BFT | C | 11/22/2013 | eng report on file | CHRISM | CHRISM | | BFT | C | 4646820 |
ALLURE HOMES LTD | BFN | C | 11/22/2013 | design and eng report on file | CHRISM | CHRISM | | BFN | C | 4646818 |
ALLURE HOMES LTD | BFN | P | 11/12/2013 | AUTHORIZED INSPECTION BY ENGINEER | REBECCA | REBECCA | REBECCA | BFN | P | 4639611 |
ALLURE HOMES LTD | BFT | P | 11/12/2013 | AUTHORIZED INSPECTION BY ENGINEER | REBECCA | REBECCA | REBECCA | BFT | P | 4639610 |
BRASIER ELECTRIC, INC. | E= | C | 08/07/2014 | generator is not installed at time of final (future) | MATTHEW | MATTHEW | | E= | C | 4792475 |
BRASIER ELECTRIC, INC. | E= | P | 08/01/2014 | Need to secure back fed breakers. | DEAN | DEAN | | E= | P | 4788809 |
BRASIER ELECTRIC, INC. | EP | R | 07/24/2014 | secure back fed breakers in sub-panel | MATTHEW | MATTHEW | | EP | R | 4783514 |
BRASIER ELECTRIC, INC. | E= | R | 07/24/2014 | secure back fed breakers in sub-panel---------------- no a/c | MATTHEW | MATTHEW | | E= | R | 4783508 |
BRASIER ELECTRIC, INC. | ES | C | 05/02/2014 | Residential Underground: 200 amp 3/w: new res--------- meter set; need seal | MATTHEW | MATTHEW | | ES | C | 4732162 |
BRASIER ELECTRIC, INC. | ER | C | 05/02/2014 | finished basement-------------- need to check mcc's, sub-panel and generator set up at time of final ---------------install main bonding jumper; check at final | MATTHEW | MATTHEW | | ER | C | 4732159 |
BRASIER ELECTRIC, INC. | EUG | C | 04/23/2014 | need address posted---------------- pvc from pedestal to home | MATTHEW | MATTHEW | | EUG | C | 4725605 |
JOLLY PLUMBING & HEATING INC. | H= | C | 07/25/2014 | Final is ok. Direct vent Boiler for HWP system. No a/c. | MARK | MARK | | H= | C | 4783968 |
DAVIS GAS SHOP INC | HO | C | 04/24/2014 | 10lb test ok. | MARK | MARK | | HO | C | 4726462 |
DAVIS GAS SHOP INC | HC | C | 04/24/2014 | 10lb test ok. | MARK | MARK | | HC | C | 4726460 |
DAVIS GAS SHOP INC | HI | C | 04/22/2014 | 12 psi test. Require 10 psi in future. note: boiler, kitchen range, dryer and bbq. 1" med. pressure. No meter release for non completed outside line. | MARKB | MARKB | | HI | C | 4724841 |
REGIONAL HEATING AND AIR CONDITIONING, INC. | HRR | C | 04/18/2014 | Boiler and venting ok. Note: Check m/a for laundry at final. Wood stove heat for bsmnt. Hydronic baseboard for main and upper levels. | MARK | MARK | | HRR | C | 4723274 |
JOLLY PLUMBING & HEATING INC. | HV | C | 04/02/2014 | boiler vent | TED | TED | | HV | C | 4713833 |
JOLLY PLUMBING & HEATING INC. | HWP | P | 04/01/2014 | 1st and 2nd floor hot water piping ok, looks like they will be baseboard and not in floor, note: boiler and boiler venting will fall under the hrr inspection, you will need to nail protect pvc boiler venting through out | TED | TED | | HWP | P | 4712710 |
JOLLY PLUMBING & HEATING INC. | HWP | P | 12/18/2013 | Baseboard under slab ok. Note: no test, no fittings. | MICHAELS | MICHAELS | | HWP | P | 4659517 |
JOLLY PLUMBING & HEATING INC. | P= | C | 07/28/2014 | UNFINISHED BASEMENT . NO IRRIGATION . POTABLE WATER CERT TO SCANNING | GABE | GABE | | P= | C | 4785065 |
JOLLY PLUMBING & HEATING INC. | PTO | C | 04/01/2014 | DWV AND WATER TEST OK | GABE | GABE | | PTO | C | 4712972 |
JOLLY PLUMBING & HEATING INC. | PB | C | 12/17/2013 | | TIM | TIM | | PB | C | 4658510 |