CONSTRUCTION BY GENESIS, INC. | B= | C | 06/27/2014 | | CHRISM | CHRISM | | B= | C | 4767111 |
CONSTRUCTION BY GENESIS, INC. | B= | R | 06/26/2014 | house locked | CHRISM | CHRISM | | B= | R | 4766191 |
CONSTRUCTION BY GENESIS, INC. | BLA | C | 03/14/2014 | | CHRISM | CHRISM | | BLA | C | 4702830 |
CONSTRUCTION BY GENESIS, INC. | BIN | C | 03/05/2014 | | CHRISM | CHRISM | | BIN | C | 4697217 |
CONSTRUCTION BY GENESIS, INC. | BFR | C | 03/05/2014 | | CHRISM | CHRISM | | BFR | C | 4697216 |
CONSTRUCTION BY GENESIS, INC. | BIN | R | 03/04/2014 | insulation ok, complete frame inspection | ED | ED | | BIN | R | 4696743 |
CONSTRUCTION BY GENESIS, INC. | BFR | T | 03/04/2014 | PAID (REC#1182194): framing items not completed | ED | ED | | BFR | T | 4696691 |
CONSTRUCTION BY GENESIS, INC. | BFR | R | 02/27/2014 | ok to insulate, missing H2.5s at trusses on dormers, bearing blocks on west end of T17 girder | CHRISM | CHRISM | | BFR | R | 4694184 |
CONSTRUCTION BY GENESIS, INC. | BSP | P | 01/31/2014 | front and rear porch roofs and posts ok, narrow wall ok | CHRISM | CHRISM | | BSP | P | 4681437 |
CONSTRUCTION BY GENESIS, INC. | BSP | P | 12/10/2013 | deck piers ok | CHRISM | CHRISM | | BSP | P | 4654464 |
CONSTRUCTION BY GENESIS, INC. | BFI | C | 12/02/2013 | R-10 at walkout | CHRISM | CHRISM | | BFI | C | 4649845 |
CONSTRUCTION BY GENESIS, INC. | BFD | C | 12/02/2013 | soils on file drain usable isolate and float | CHRISM | CHRISM | | BFD | C | 4649844 |
CONSTRUCTION BY GENESIS, INC. | BFN | C | 12/02/2013 | design and eng report on file | CHRISM | CHRISM | | BFN | C | 4649841 |
CONSTRUCTION BY GENESIS, INC. | BFT | C | 12/02/2013 | eng report on file | CHRISM | CHRISM | | BFT | C | 4649840 |
CONSTRUCTION BY GENESIS, INC. | BFN | P | 11/15/2013 | AUTHORIZED INSPECTION BY ENGINEER | JANE | JANE | JANE | BFN | P | 4642505 |
CONSTRUCTION BY GENESIS, INC. | BFT | P | 11/15/2013 | AUTHORIZED INSPECTION BY ENGINEER | JANE | JANE | JANE | BFT | P | 4642504 |
POSITIVE ELECTRIC, LLC | E= | C | 06/04/2014 | 40 amp a/c installed, hot tub pre-wire | MATTHEW | MATTHEW | | E= | C | 4751517 |
POSITIVE ELECTRIC, LLC | E= | R | 06/02/2014 | need 2 small appliance circuits to feed kitchen countertops, gfci protect outlet within 6' of laundry sink and outlet under wet bar countertop, energized nm coiled behind furnace needs to land in box and be safed off, outlet in basement bedroom that needed to be added on rough inspection was not installed, what is the uf coiled under panel and 1 1/2" schedule 40 pvc riser for (riser needs to be sch 80), id white wire at a/c disconnect------------------- a/c and hot tub pre-wires | MATTHEW | MATTHEW | | E= | R | 4749364 |
POSITIVE ELECTRIC, LLC | ER | C | 02/21/2014 | add outlet in basement bedroom at door (more than 1' pass door swing) check at final -----------------------finished basement, 1-20 | MATTHEW | MATTHEW | | ER | C | 4691301 |
POSITIVE ELECTRIC, LLC | ES | C | 02/21/2014 | Residential Underground: 200 amp 3/w: new res---- meter is set--- need seal | MATTHEW | MATTHEW | | ES | C | 4691291 |
POSITIVE ELECTRIC, LLC | EUG | C | 12/24/2013 | 4/0 urd ok | TOMC | TOMC | | EUG | C | 4662442 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | C | 06/11/2014 | correction made | TED | TED | | H= | C | 4755824 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | H= | P | 06/09/2014 | Need to clear stucco from direct vent termination. Lower lever bath fan damper stuck w/ stucco. Need a low grill to mech rm for w/h c/a. Rest ok. Fin Bsmnt and has a/c. | MARK | MARK | | H= | P | 4753852 |
FENTON PLUMBING & HEATING INC | HC | C | 02/25/2014 | RELEASE METER 10lb test ok. | MARK | MARK | | HC | C | 4693061 |
FENTON PLUMBING & HEATING INC | HI | C | 02/25/2014 | 10 lb test ok. Note: 1 1/4" main, furn, cook top, f/p, bbq, 2 ea. w/h. | MARK | MARK | | HI | C | 4693020 |
CAPITAL VIEW GENERAL CONSTRUCTION, INC. | HRR | C | 02/18/2014 | finished basement, a/c rough, outside air to return, duct design | TED | TED | | HRR | C | 4688312 |
FENTON PLUMBING & HEATING INC | P= | C | 06/25/2014 | CORRECTIONS MADE | GABE | GABE | | P= | C | 4764917 |
FENTON PLUMBING & HEATING INC | P= | P | 06/18/2014 | IRRIGATION LINE CAPPED IN MEC ROOM NO PVB INSTALLED . MASTER SHOWER NOT READY . REST OK. POTABLE WATER CERT TO SCANNING | GABE | GABE | | P= | P | 4760222 |
FENTON PLUMBING & HEATING INC | PTO | C | 02/21/2014 | | JOEL | JOEL | | PTO | C | 4691098 |
FENTON PLUMBING & HEATING INC | PWO | C | 12/20/2013 | | TIM | TIM | | PWO | C | 4661291 |
FENTON PLUMBING & HEATING INC | PB | C | 12/10/2013 | | JOEL | JOEL | | PB | C | 4654528 |