GOEBEL CONSTRUCTION, INC | B= | C | 05/06/2014 | | CHRISM | CHRISM | | B= | C | 4733418 | GOEBEL CONSTRUCTION, INC | B= | P | 04/25/2014 | Additional Inspections Required: External Agency Inspection F= by FIREDEPT is not Completed yet, External Agency Inspection HD= by HEALTHDEPT is not Completed yet, Plumbing Final Inspection is not Completed yet. need a guardrail at end of front porch -- Schedule a new Building Final when above items are complete. | CHRISM | CHRISM | | B= | P | 4727298 | GOEBEL CONSTRUCTION, INC | BLA | C | 02/24/2014 | | CHRISM | CHRISM | | BLA | C | 4692030 | GOEBEL CONSTRUCTION, INC | BIN | C | 02/19/2014 | | CHRISM | CHRISM | | BIN | C | 4689594 | GOEBEL CONSTRUCTION, INC | BFR | P | 02/18/2014 | check for ridge vent at rafter roof | CHRISM | CHRISM | | BFR | P | 4688299 | GOEBEL CONSTRUCTION, INC | BFR | R | 02/14/2014 | ok to insulate, strong back garage gables, ladder frame under dormer walls, need continuous ridge vent at rafter roof | CHRISM | CHRISM | | BFR | R | 4687430 | GOEBEL CONSTRUCTION, INC | BSP | P | 01/16/2014 | front and rear porch roof and posts ok | CHRISM | CHRISM | | BSP | P | 4673257 | GOEBEL CONSTRUCTION, INC | BSP | R | 01/15/2014 | ledger not connected per plan / roll block rafter heels on front porch / roll block truss heels on rear porch | JOHN | JOHN | | BSP | R | 4672479 | GOEBEL CONSTRUCTION, INC | BFI | C | 01/07/2014 | underslab R-10 ok | CHRISM | CHRISM | | BFI | C | 4667451 | GOEBEL CONSTRUCTION, INC | BSP | P | 12/16/2013 | deck and front porch piers ok | CHRISM | CHRISM | | BSP | P | 4657486 | GOEBEL CONSTRUCTION, INC | BFD | C | 12/09/2013 | drain usable ok | CHRISM | CHRISM | | BFD | C | 4653929 | GOEBEL CONSTRUCTION, INC | BFN | C | 12/02/2013 | design and soils on file drain usable isolate and float | CHRISM | CHRISM | | BFN | C | 4649962 | GOEBEL CONSTRUCTION, INC | BFT | C | 11/21/2013 | 3000# bearing pads ok | CHRISM | CHRISM | | BFT | C | 4646278 | SANCHEZ ELECTRIC, INC. | E= | C | 04/23/2014 | no a/c | MATTHEW | MATTHEW | | E= | C | 4725648 | SANCHEZ ELECTRIC, INC. | E= | R | 04/22/2014 | expose ufer, can't have pendant light at master tub, ground cut-in box for master bath outlet under cabinet, trim back exterior can lights, protect nm in mech room by well disconnect, install cover on j-box above well disconnect, bond spa motor to outlet equipment ground----------- no a/c | MATTHEW | MATTHEW | | E= | R | 4724771 | SANCHEZ ELECTRIC, INC. | ER | C | 02/13/2014 | | MATTHEW | MATTHEW | | ER | C | 4686770 | SANCHEZ ELECTRIC, INC. | ER | R | 02/12/2014 | hood needs dedicated circuit, hot tub needs to be fed from service panel---------- 125 amp sub-panel fed with 2/0 al not in insulation---------- 2-15 in sub panel, 2-15 in service panel--- finished basement---------------------------- no issues on electrical side if building inspector wants to piggyback frame inspection | MATTHEW | MATTHEW | | ER | R | 4686044 | SANCHEZ ELECTRIC, INC. | ES | C | 02/11/2014 | Residential Underground: 200 amp 3-w ok to re seal meter | BRIAN | BRIAN | | ES | C | 4685222 | SANCHEZ ELECTRIC, INC. | ER | R | 02/11/2014 | not ready---- | BRIAN | BRIAN | | ER | R | 4685221 | SANCHEZ ELECTRIC, INC. | EUG | C | 12/19/2013 | service lateral from pole to panel | MATTHEW | MATTHEW | | EUG | C | 4660351 | A & Z MECHANICAL, INC. | H= | C | 03/13/2014 | Boiler only, ok. | MARK | MARK | | H= | C | 4701829 | MICK HEATING & SHEET METAL CO. | HC | C | 02/06/2014 | RELEASE METER | DAVIDH | DAVIDH | | HC | C | 4683711 | MICK HEATING & SHEET METAL CO. | HRR | C | 02/06/2014 | OK | DAVIDH | DAVIDH | | HRR | C | 4683710 | A & Z MECHANICAL, INC. | HWP | C | 02/06/2014 | 100 LB TEST OK | DAVIDH | DAVIDH | | HWP | C | 4683705 | A & Z MECHANICAL, INC. | HRR | R | 02/04/2014 | NOT READY | DAVIDH | DAVIDH | | HRR | R | 4682617 | AMERICAN PRIDE PLUMBING | HI | C | 01/29/2014 | 10 LB TEST OK NOTE 1 1/4" LINE 1 BOILER,1 F/P,1 BBQ,1 RANGE AND 1 GARAGE HEATER | DAVIDH | DAVIDH | | HI | C | 4679880 | A & Z MECHANICAL, INC. | HWP | P | 01/07/2014 | 100 LB TEST OK NOTE LOWER LEVEL OK TO POUR | DAVIDH | DAVIDH | | HWP | P | 4667634 | AMERICAN PRIDE PLUMBING | P= | C | 04/30/2014 | RECEIVED POTABLE H20 REPORT | LEE | LEE | | P= | C | 4730259 | AMERICAN PRIDE PLUMBING | P= | P | 04/23/2014 | PENDING POTABLE WATER CERTIFICATE. | GABE | GABE | | P= | P | 4725476 | AMERICAN PRIDE PLUMBING | PTO | C | 01/30/2014 | | JOEL | JOEL | | PTO | C | 4680664 | AMERICAN PRIDE PLUMBING | PTO | P | 01/29/2014 | low test dwv master, master tub has horizontal dry vent | JOEL | JOEL | | PTO | P | 4680055 | AMERICAN PRIDE PLUMBING | PWO | C | 12/18/2013 | | TIM | TIM | | PWO | C | 4659541 | AMERICAN PRIDE PLUMBING | PB | C | 12/18/2013 | | TIM | TIM | | PB | C | 4659534 |
|
|