ROCK SOLID DEVELOPMENT LLC | B= | C | 07/08/2014 | All other required Final inspections are complete. (This is a computer generated result) | CHRISM | CHRISM | | B= | C | 4772471 |
ROCK SOLID DEVELOPMENT LLC | B= | P | 07/07/2014 | Additional Inspections Required: External Agency Inspection HD= by HEALTHDEPT is not Completed yet. | CHRISM | CHRISM | | B= | P | 4771693 |
ROCK SOLID DEVELOPMENT LLC | B= | P | 06/13/2014 | Temp CO: to occupy ( Expires: 7/13/2014 12:00:00 AM) | REBECCA | REBECCA | | B= | P | 4757296 |
ROCK SOLID DEVELOPMENT LLC | B= | P | 06/06/2014 | Additional Inspections Required: External Agency Inspection HD= by HEALTHDEPT is not Completed yet, Plumbing Final Inspection is not Completed yet. address numbers on house, post to truss connections at front porch -- Schedule a new Building Final when above items are complete. | CHRISM | CHRISM | | B= | P | 4753106 |
ROCK SOLID DEVELOPMENT LLC | BSP | P | 04/30/2014 | deck piers on seperate permit | CHRISM | CHRISM | | BSP | P | 4730188 |
ROCK SOLID DEVELOPMENT LLC | BFR | C | 03/14/2014 | | CHRISM | CHRISM | | BFR | C | 4702686 |
ROCK SOLID DEVELOPMENT LLC | BIN | C | 03/10/2014 | | CHRISM | CHRISM | | BIN | C | 4699654 |
ROCK SOLID DEVELOPMENT LLC | BFR | P | 03/10/2014 | need to check drywall behind elect panel | CHRISM | CHRISM | | BFR | P | 4699648 |
ROCK SOLID DEVELOPMENT LLC | BFR | P | 03/04/2014 | add 5/8 drywall at stud cavity behind electrical panel on common wall, (3) floor joists- top cord damaged, either need engineer repair or header out repair, truss repairs on file, missing laterals on A1,B1, B2,B3,B4,B5,B6,B9,B10,B13,B14 trussesFHA strap gable and A35 gable wall, FHA strap top plate in basement, anchor bolrt at plate break in garage, ok to insulate | ED | ED | | BFR | P | 4696631 |
ROCK SOLID DEVELOPMENT LLC | BLA | C | 02/25/2014 | | CHRISM | CHRISM | | BLA | C | 4692633 |
ROCK SOLID DEVELOPMENT LLC | BSP | P | 02/13/2014 | met with contractor about electric panel in common wall , will back rock by frame | CHRISM | CHRISM | | BSP | P | 4686702 |
ROCK SOLID DEVELOPMENT LLC | BSP | P | 01/17/2014 | front and rear porch roofs ok, front porch piers ok | CHRISM | CHRISM | | BSP | P | 4673983 |
ROCK SOLID DEVELOPMENT LLC | BSP | T | 12/18/2013 | PAID (REC#1175384) PLAN SPLICE FEE: $50 by: DANM for Construction: Foundation change to a walkout | DANM | DANM | | BSP | T | 4659376 |
ROCK SOLID DEVELOPMENT LLC | BFI | C | 11/27/2013 | R-10 at walkout | CHRISM | CHRISM | | BFI | C | 4648967 |
ROCK SOLID DEVELOPMENT LLC | BFD | P | 11/27/2013 | drain usable ok, need stamped open hole for file | CHRISM | CHRISM | | BFD | P | 4648965 |
ROCK SOLID DEVELOPMENT LLC | BFN | C | 11/27/2013 | eng report on file | CHRISM | CHRISM | | BFN | C | 4648964 |
ROCK SOLID DEVELOPMENT LLC | BFT | C | 11/27/2013 | eng report on file | CHRISM | CHRISM | | BFT | C | 4648962 |
ROCK SOLID DEVELOPMENT LLC | BFN | R | 11/26/2013 | need eng inspection report | CHRISM | CHRISM | | BFN | R | 4648336 |
ROCK SOLID DEVELOPMENT LLC | BFT | R | 11/26/2013 | need eng inspection report | CHRISM | CHRISM | | BFT | R | 4648333 |
ROCK SOLID DEVELOPMENT LLC | BFD | R | 11/26/2013 | no paperwork on site | CHRISM | CHRISM | | BFD | R | 4648329 |
MEYER ELECTRIC | E= | C | 06/05/2014 | no a/c | MATTHEW | MATTHEW | | E= | C | 4752510 |
MEYER ELECTRIC | E= | R | 06/04/2014 | gfci outlet behind washer, gfci outlet right of laundry sink, no power to front outlet on deck, afci hall light off garage, guard crawler lights, outlet buried in office off living room | MATTHEW | MATTHEW | | E= | R | 4751575 |
MEYER ELECTRIC | E= | R | 06/03/2014 | complete re-inspect-------- lights not working, kitchen 3-ways wired wrong, missing inter-system bond terminal, ge breakers installed in siemens panel, breaker won't set, provide means to check OH door (no power to OH door), need gfci breakers for spa (gfci tests not readily accessible), bond tub heater and motor to equipment ground at receps---------- contractor needs to check house before recall---- I didn't finish inspection | MATTHEW | MATTHEW | | E= | R | 4750269 |
MEYER ELECTRIC | EUG | C | 03/13/2014 | service lateral from pole to home | MATTHEW | MATTHEW | | EUG | C | 4701996 |
MEYER ELECTRIC | ES | C | 03/13/2014 | Residential Overhead: 200 amp 3/w: new res---- meter is set; need seal---------------inspectors note: land neutrals to neutral bar; install only 2 screws so we can check at time of final------------------ | MATTHEW | MATTHEW | | ES | C | 4701989 |
MEYER ELECTRIC | EUG | R | 03/12/2014 | wire not installed | MATTHEW | MATTHEW | | EUG | R | 4701183 |
MEYER ELECTRIC | ER | C | 02/14/2014 | sheetrock around panel approved by c. morin | MATTHEW | MATTHEW | | ER | C | 4687097 |
MEYER ELECTRIC | ER | R | 02/12/2014 | need building inspector to contact me with fix for panel in fire wall | MATTHEW | MATTHEW | | ER | R | 4686071 |
MEYER ELECTRIC | ER | R | 02/10/2014 | add outlet under kitchen switches where the wall got extended --------------- ground fan box --------- add light box in kitchen -------------- land nm cable in fire place ---------------- have contractor get a hold of building inspector to find out the requirements for panel inside fire rated wall | CRAIG | CRAIG | | ER | R | 4684788 |
MEYER ELECTRIC | ER | R | 02/05/2014 | check spacing of outlets in bed room next to the kitchen ----------------- nail plate where the pvc comes to the panel in the garage ------------- 2 - 20 2 - 10/3 to well / dryer 2 - 6/3 al to range / outlet in garage unfinished basement | CRAIG | CRAIG | | ER | R | 4683514 |
HVAC SOLUTIONS, INC. | H= | C | 05/29/2014 | Damper is ok. | MARK | MARK | | H= | C | 4747421 |
HVAC SOLUTIONS, INC. | H= | R | 05/27/2014 | No damper on OSA to return. Rest ok. | MARK | MARK | | H= | R | 4745682 |
O.M.A.G.M., INC. | HO | C | 03/14/2014 | test ok. | DICK | DICK | | HO | C | 4703119 |
HVAC SOLUTIONS, INC. | HC | C | 02/28/2014 | RELEASE METER | MARK | MARK | | HC | C | 4694738 |
HVAC SOLUTIONS, INC. | HRR | C | 02/28/2014 | Damper was covered with insulation and not visible at inspection. Per contractor. | MARK | MARK | | HRR | C | 4694737 |
HVAC SOLUTIONS, INC. | HRR | P | 02/27/2014 | I do not see a damper for OSA. It is still located more than 12' from the blower motor. Rest ok. | MARK | MARK | | HRR | P | 4694365 |
HVAC SOLUTIONS, INC. | HRR | R | 02/25/2014 | outside to return over 12 feet from blower, install damper or move it, seal water line run into return at bottom of stairs in basement ceiling, note: unfinished basement, no a/c, conditioned crawlspace, duct design | TED | TED | | HRR | R | 4693024 |
O.M.A.G.M., INC. | HI | C | 02/12/2014 | 10 LB TEST OK NOTE 1 " LINE 1 FURN, 1 W/H, 1 F/P AND 1 C/T | DAVIDH | DAVIDH | | HI | C | 4685946 |
HOGAN MECHANICAL, INC. | P= | C | 05/30/2014 | POTABLE WATER CERT TO SCANNING | GABE | GABE | | P= | C | 4748249 |
HOGAN MECHANICAL, INC. | PWO | C | 04/03/2014 | TRANSITION TO COPPER USING FLAIR FITTING FITTING IN DITCH. | GABE | GABE | | PWO | C | 4714109 |
HOGAN MECHANICAL, INC. | PTO | C | 01/30/2014 | unfinished basement | JOEL | JOEL | | PTO | C | 4680683 |
HOGAN MECHANICAL, INC. | PB | C | 12/19/2013 | | TIM | TIM | | PB | C | 4660506 |