ZOOK CONTRACTING, INC. | B= | C | 06/02/2014 | | CHRISM | CHRISM | | B= | C | 4748921 | ZOOK CONTRACTING, INC. | BSP | C | 05/29/2014 | unfinished basement | CHRISM | CHRISM | | BSP | C | 4747968 | ZOOK CONTRACTING, INC. | BIN | C | 03/05/2014 | | CHRISM | CHRISM | | BIN | C | 4697122 | ZOOK CONTRACTING, INC. | BFR | C | 03/03/2014 | | CHRISM | CHRISM | | BFR | C | 4695887 | ZOOK CONTRACTING, INC. | BLA | C | 03/03/2014 | | CHRISM | CHRISM | | BLA | C | 4695886 | ZOOK CONTRACTING, INC. | BFR | R | 02/28/2014 | ok to insulate, missing lateral A trusses, brace laterals to roof deck | CHRISM | CHRISM | | BFR | R | 4695203 | ZOOK CONTRACTING, INC. | BSP | P | 02/18/2014 | porch and posts ok | CHRISM | CHRISM | | BSP | P | 4688649 | ZOOK CONTRACTING, INC. | BFI | C | 01/13/2014 | | CHRISM | CHRISM | | BFI | C | 4670603 | ZOOK CONTRACTING, INC. | BFD | C | 01/13/2014 | | CHRISM | CHRISM | | BFD | C | 4670598 | ZOOK CONTRACTING, INC. | BFT | C | 01/13/2014 | eng report on file | CHRISM | CHRISM | | BFT | C | 4670587 | ZOOK CONTRACTING, INC. | BFN | C | 01/13/2014 | eng report on file | CHRISM | CHRISM | | BFN | C | 4670586 | ZOOK CONTRACTING, INC. | BFD | P | 01/10/2014 | soils on file drain usable ok, isolate and float, clear BFT, BFN | CHRISM | CHRISM | | BFD | P | 4670179 | ZOOK CONTRACTING, INC. | BFN | R | 01/10/2014 | design on file need eng report | CHRISM | CHRISM | | BFN | R | 4670178 | ZOOK CONTRACTING, INC. | BFT | R | 01/10/2014 | need eng report | CHRISM | CHRISM | | BFT | R | 4670173 | ZOOK CONTRACTING, INC. | BFN | P | 01/09/2014 | AUTHORIZED INSPECTION BY ENGINEER | TERRI | TERRI | TERRI | BFN | P | 4669208 | ZOOK CONTRACTING, INC. | BFT | P | 01/09/2014 | AUTHORIZED INSPECTION BY ENGINEER | TERRI | TERRI | TERRI | BFT | P | 4669207 | ZOOK CONTRACTING, INC. | BFI | P | 01/08/2014 | R-10 at walkout wall ok, | CHRISM | CHRISM | | BFI | P | 4668545 | LAKE STAR ELECTRIC, INC. | E= | C | 05/23/2014 | a/c pre-wire | MATTHEW | MATTHEW | | E= | C | 4745257 | LAKE STAR ELECTRIC, INC. | E= | R | 05/22/2014 | cannot have switched receptacles above door in closet for lighting | TOMC | TOMC | | E= | R | 4744423 | LAKE STAR ELECTRIC, INC. | ES | C | 05/22/2014 | Residential Underground: 200 amp main panel 125 sub panel | TOMC | TOMC | | ES | C | 4744422 | LAKE STAR ELECTRIC, INC. | ES | R | 03/03/2014 | temp needs to be removed------ 200 amp service | MATTHEW | MATTHEW | | ES | R | 4695965 | LAKE STAR ELECTRIC, INC. | EUG | C | 03/03/2014 | | MATTHEW | MATTHEW | | EUG | C | 4695961 | LAKE STAR ELECTRIC, INC. | ER | C | 02/24/2014 | unfinished basement, no mcc's, #6al to cooking equipment, sub-panel not breakered | MATTHEW | MATTHEW | | ER | C | 4691757 | ARROW HAWK HEATING, LLC | H= | C | 05/23/2014 | basement bathroom finished only, no a/c | TED | TED | | H= | C | 4745046 | ARROW HAWK HEATING, LLC | HC | C | 02/26/2014 | RELEASE METER | MARK | MARK | | HC | C | 4693389 | ARROW HAWK HEATING, LLC | HRR | C | 02/26/2014 | rough and D/D ok. Note: perf test received and sent to scan. | MARK | MARK | | HRR | C | 4693388 | ARROW HAWK HEATING, LLC | HRR | R | 02/25/2014 | No duct design or equip docs found on site. | MARK | MARK | | HRR | R | 4693042 | L & L GAS SHOP, LLC. | HI | C | 02/19/2014 | 1 1/4'' furnace, 2-water heaters, fireplace, dryer | TED | TED | | HI | C | 4689892 | TIMBERWOLF PLUMBING, INC. | P= | C | 05/15/2014 | REST OK . NOTE: UNFINISHED BASEMENT WITH FINISHED BATH. NO IRRIGATION . POTABLE WATER CERTIFICATE SENT TO SCANNING | GABE | GABE | | P= | C | 4739156 | HOMEOWNER | PWO | C | 03/14/2014 | | TIM | TIM | | PWO | C | 4702971 | TIMBERWOLF PLUMBING, INC. | PTO | C | 02/20/2014 | bath in basement complete | JOEL | JOEL | | PTO | C | 4690281 | TIMBERWOLF PLUMBING, INC. | PB | C | 01/13/2014 | | JOEL | JOEL | | PB | C | 4670927 |
|
|