SUNSET DREAM HOMES, INC | B= | C | 12/23/2014 | | DAN | DAN | | B= | C | 4877256 |
SUNSET DREAM HOMES, INC | B= | R | 12/09/2014 | need handrail at porch and garage | DALE | DALE | | B= | R | 4867729 |
SUNSET DREAM HOMES, INC | BSP | P | 09/10/2014 | lath completed | ED | ED | | BSP | P | 4813635 |
SUNSET DREAM HOMES, INC | BSP | R | 09/09/2014 | missing weep holes in screed, lath not competed. | ED | ED | | BSP | R | 4812957 |
SUNSET DREAM HOMES, INC | BSP | P | 08/26/2014 | (3) ledger locks at 12" o.c., check on thru bolts for 4 ply beam, post connections lid framing ok | ED | ED | | BSP | P | 4804398 |
SUNSET DREAM HOMES, INC | BSP | T | 07/28/2014 | PAID (REC#1210044) PLAN SPLICE FEE: $50 by: DANM for Construction: Added deck and cover | DANM | DANM | | BSP | T | 4784846 |
SUNSET DREAM HOMES, INC | BIN | C | 05/16/2014 | | ED | ED | | BIN | C | 4740638 |
SUNSET DREAM HOMES, INC | BFR | C | 05/16/2014 | | ED | ED | | BFR | C | 4740633 |
SUNSET DREAM HOMES, INC | BLA | C | 05/08/2014 | | CHRISM | CHRISM | | BLA | C | 4735268 |
SUNSET DREAM HOMES, INC | BFR | R | 05/07/2014 | ok to insulate, all draftstop, missing dbl H2.5s at G-G2-G3-G4 and F trusses | CHRISM | CHRISM | | BFR | R | 4734785 |
SUNSET DREAM HOMES, INC | BLA | R | 05/07/2014 | extend electric boxes to front of stucco | CHRISM | CHRISM | | BLA | R | 4734784 |
SUNSET DREAM HOMES, INC | BSP | P | 04/24/2014 | porch roof and piers ok, letter on file | CHRISM | CHRISM | | BSP | P | 4726410 |
SUNSET RIDGE DREAM HOMES | BFD | C | 12/24/2013 | soils report on file | ED | ED | | BFD | C | 4662491 |
SUNSET RIDGE DREAM HOMES | BFN | C | 12/24/2013 | design on file | ED | ED | | BFN | C | 4662490 |
SUNSET RIDGE DREAM HOMES | BFT | C | 12/24/2013 | engineer inspection letter for footing on file | ED | ED | | BFT | C | 4662489 |
SUNSET RIDGE DREAM HOMES | BFD | P | 12/17/2013 | need soils | DALE | DALE | | BFD | P | 4658117 |
SUNSET RIDGE DREAM HOMES | BFI | C | 12/17/2013 | | DALE | DALE | | BFI | C | 4658116 |
SUNSET RIDGE DREAM HOMES | BFN | P | 12/17/2013 | ok per eng. / need clean foundation design | DALE | DALE | | BFN | P | 4658115 |
SUNSET RIDGE DREAM HOMES | BFT | P | 12/17/2013 | ok per eng. /need open hole | DALE | DALE | | BFT | P | 4658114 |
HOMEOWNER | E= | C | 10/02/2014 | | JOSEPH | JOSEPH | | E= | C | 4827853 |
HOMEOWNER | E= | R | 09/30/2014 | --------------Cage open bulb in mechanical room.----------- GFCI protection for gas heater.--------------------------Notes ac and hot tub are pre roughed | JOSEPH | JOSEPH | | E= | R | 4826047 |
HOMEOWNER | E= | R | 09/24/2014 | Complete re-inspection required. Following is a partial list only. GFCI protection missing for some 120 volt outlets in garage and laundry room. -------------- Don't install reset for gfci behind appliance.----------------- Arc shields missing in kitchen and tiled areas.----------- Appliance lockout for cook-top.-------------- Decora switches installed upside down.------------- Install test lights in soffit receptacles for GFCI verification.-------------------Clothes closets MAY have open bulbs (hard to tell if the cover is a shower trim.) If not open bulb please leave ladder under fixture in clothes closet.---------- Expose ufer------- AFCI protection per 2011 nec------------ ID smokes---------- Why is breaker for future hot tub taped off------------- Too much to list, had to stop after 40 minutes.---------------------- notes ac and hot tub are prewired. | JOSEPH | JOSEPH | | E= | R | 4822544 |
HOMEOWNER | ER | C | 05/02/2014 | Finished basement-------------------- 6/3 al 6/3 cu sub panel ok | JOSEPH | JOSEPH | | ER | C | 4732141 |
HOMEOWNER | ES | C | 04/28/2014 | Residential Underground: 200 amp 3w new res meter in and sealed no action required | JOSEPH | JOSEPH | | ES | C | 4728558 |
FRONT RANGE HEATING & COOLING | H= | C | 09/29/2014 | correction made | TED | TED | | H= | C | 4824364 |
FRONT RANGE HEATING & COOLING | H= | P | 09/26/2014 | need c/a to mech room, plug condensate drain hole in coil...rest ok | TIM | TIM | | H= | P | 4824142 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | HC | C | 05/06/2014 | RELEASE METER, need letter for 2lb system | TED | TED | | HC | C | 4733854 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | HI | C | 05/06/2014 | by final need letter for 2lb system, note: 1 1/4'' furnace, w/h, garage heater, 3-fireplaces | TED | TED | | HI | C | 4733853 |
O.M.A.G.M., INC. | HO | C | 05/05/2014 | 10lb test on old and new under ground piping from meter at road to rear of house, if this is a 2 lb system will need to label risers and a letter from black hills | TED | TED | | HO | C | 4732964 |
FRONT RANGE HEATING & COOLING | HRR | C | 05/02/2014 | BY NEED PLAN SHOWING OSA REMOVED - REST OK | JERRYF | JERRYF | | HRR | C | 4732319 |
FRONT RANGE HEATING & COOLING | HRR | P | 04/29/2014 | NEED GREAT ROOM FIREPLACE INSTALL MANUAL TO VERIFY INSTALL - NEED ALL BATH FAN VENTS INSULATED TO FAN AND FURNACE FLUES INSULATED TO SHEET ROCK CANNOT USE BLOWN IN INSULATION TO COVER - PLANS SHOWS OSA NONE INSTALLED ??? - REST OK. NOTES: DUCT DESIGN AND FURNACE OK - AC ROUGH - FINISHED BASEMENT - DIRECT VENT FURNACE | JERRYF | JERRYF | | HRR | P | 4729468 |
FRONT RANGE HEATING & COOLING | HRR | R | 04/25/2014 | COMPLETE BATH FAN VENT IN GARAGE - SEAL ALL WOOD RETURN AIR HEADERS - MASTER BATH FAN VENT BROKEN - NEED FIREPLACE MANUALS - NEED NAIL PROTECTION ON LINESET - COMPLETE ALL DUCT SEAL - STOPPED INSPECTION - NOT READY - RE INSPECT ALL | JERRYF | JERRYF | | HRR | R | 4727417 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | P= | C | 10/29/2014 | received potable water cert | TIM | TIM | | P= | C | 4843811 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | P= | P | 09/25/2014 | need proof of potable water | TIM | TIM | | P= | P | 4823063 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | PWO | C | 05/07/2014 | | TIM | TIM | | PWO | C | 4734864 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | PTO | C | 05/06/2014 | | TIM | TIM | | PTO | C | 4733963 |
ROCKY MOUNTAIN RADIANT HEATING & PLUMBING, INC. | PB | C | 12/26/2013 | | TED | TED | | PB | C | 4662807 |